Accueil Produits TransformateurTransformateur à bain d'huileTransformateur de puissance triphasé étanche à l'huile S11-M

Transformateur de puissance triphasé étanche à l'huile S11-M

Developed and manufactured by Shenheng Power, the S11-M series fully sealed oil-immersed power transformer is a high-efficiency, eco-friendly outdoor power distribution solution. It features ultra-low power loss, low operational noise and superior energy conversion efficiency, delivering remarkable energy-saving performance while reducing operational pollution. Different from conventional oil-immersed transformers, this upgraded fully sealed model eliminates the traditional oil conservator. It adopts a corrugated oil tank structure, where the elastic deformation of corrugated sheets automatically compensates and adjusts oil volume changes caused by temperature fluctuations.

S11-M Fully Sealed Oil Immersed Power Transformer

The S11-M fully sealed oil-immersed power transformer is a premium three-phase outdoor power distribution transformer independently developed and produced by Shenheng Power. Optimized for outdoor grid operation, industrial power supply and civil power distribution scenarios, this series of transformers integrates low-loss core technology, silent operation design and fully sealed protection structure. It effectively solves the common pain points of traditional transformers, such as easy oil oxidation, frequent maintenance, high energy consumption and poor environmental adaptability. With outstanding energy-saving benefits, stable mechanical performance and maintenance-free operation, it complies with international power distribution standards and is widely applicable to various medium and low-voltage power transmission and distribution projects.

The fully isolated design completely separates internal insulating oil from outside air, effectively inhibiting oil deterioration and insulating material aging. This greatly enhances overall operational stability and realizes maintenance-free performance under normal operating conditions, making it an ideal long-term reliable choice for outdoor power distribution systems.

Technical Parameters

Rated Power Capacity 25KVA – 2500KVA, covering diverse power demand scenarios
Voltage Level Standard 10KV, 11KV, 13.8KV, 15KV, 17.5KV, 20KV, 22KV, 24KV, 30KV, 33KV, 35KV, 36KV;
customized special voltage levels are available per customer requirements
Voltage Regulation Type Off-circuit voltage regulation / On-load voltage regulation (optional)
Tapping Range ±5%, ±2×2.5%, ±4×2.5%
Rated Frequency 50Hz or 60Hz (customizable)
Phase Number Single-phase / Three-phase (optional)
Connection Symbol Standard Dyn11, Yyn0; customizable per project technical specifications
Short-Circuit Impedance Adopts international standard impedance values
Applicable Working Conditions Standard working altitude ≤1000m, maximum ambient temperature ≤40℃. For projects
exceeding standard conditions, we provide professional parameter optimization and
customized adjustment to ensure stable equipment operation.

Transformateur électrique de distribution de puissance triphasé extérieur de type S11-M entièrement étanche immergé dans l'huile

Superior Structural Characteristics & Technical Advantages

1.High-Performance Iron Core

The transformer core is made of high-quality 30Z140 non-time-effect cold-rolled grain-oriented silicon steel sheets. Processed by professional George cutting lines, the core sheets feature burr-free cutting, flat surface and uniform texture. It adopts an integral pull-plate clamping structure, with upper and lower yokes firmly fixed by clamping plates to form a stable frame structure. Combined with precision hierarchical lamination technology, the design effectively suppresses no-load loss, reduces electromagnetic vibration and greatly lowers operational noise, achieving excellent low-loss and silent operation effects.

2.Reliable Winding Structure

The winding adopts mature and optimized structural design, with stable coil layout and uniform stress distribution, fully guaranteeing long-term operational reliability of the transformer. Strict production control ensures the inter-turn insulating electric field strength is no more than 1.6kV/mm, effectively preventing inter-turn breakdown and insulation failure, and improving the overall electrical safety margin of the equipment.

3.Optimized Integral Body Insulation

The main body adopts a mature and scientific insulation system, with strictly controlled axial insulation margins to eliminate potential insulation risks. Most components adopt integral multi-coil assembly technology, processed through constant-pressure evaporation treatment. This enables uniform coil shrinkage, low rebound rate, and significantly improved electrical withstand strength and mechanical stability. Equipped with laminated wood boards and thermoformed insulating cardboard, and fixed with pin-type compression structure, the winding maintains continuous and stable compression state to avoid loose displacement during long-term operation.

4.Reasonable Leading Wire Layout

All internal leading wires are scientifically arranged with standardized wiring routes, ensuring sufficient electrical safety distance and excellent mechanical strength. The overall circular wiring structure guarantees reliable plug-in and crimping connection, avoiding poor contact, wire loosening and other common faults, and improving the stability of internal circuit transmission.

5.Reinforced Sealed Oil Tank

The oil tank adopts a flat-top bell jar structure, which enhances the overall mechanical rigidity and impact resistance of the equipment, while presenting a neat and elegant appearance and simplifying on-site installation and maintenance. The top pipeline and bushing lifting support are designed with a gradient structure matching the gas relay, which facilitates smooth gas circulation and ensures timely and accurate fault detection. The tank undergoes professional vacuum oil injection treatment, with strict vacuum pumping test (759mmHg) and 24-hour overload oil pressure test (2 times of standard oil conservator pressure), achieving zero leakage and no permanent deformation. The structural design supports convenient disassembly and replacement of bushings and porcelain components. A drain valve is arranged at the bottom of the oil tank and a sampling valve in the middle, facilitating daily oil sampling detection and equipment maintenance. A centralized gas connecting pipe is fixed on the bushing support. The upper and lower oil tanks are fully welded as a whole to realize complete sealing and isolate external air and moisture.

6.Practical Oil Conservator

Equipped with a capsule-type oil conservator with pointer-type oil level indicator, the structure supports convenient internal cleaning and daily inspection. The tank capacity is scientifically calibrated to avoid oil overflow under full-load operation at 40℃ high temperature, and clear oil level display is guaranteed at -25℃ low temperature before operation. Matched with an oil-sealed moisture absorber, it effectively blocks external moisture and dust from entering the tank.

7.Complete Safety Protection Devices

The transformer is equipped with a standard gas relay that fully complies with ZBK41004-89 industry standards, realizing real-time monitoring of internal gas changes and early warning of potential faults. It is fitted with sufficient and reliable pressure relief devices and matched with downward oil spray pipes, which can quickly release internal pressure in case of abnormal conditions to avoid equipment damage and ensure operational safety.

8.Precise Oil Temperature Measuring System

A professional mercury thermometer bracket is reserved on the top of the oil tank, equipped with a high-precision temperature controller. All temperature measuring components meet industry standard accuracy requirements, and the configuration quantity and technical parameters can be adjusted according to tender and project demands, realizing real-time monitoring of equipment operating temperature.

9.Standardized Factory Prefabrication & Inspection

All transformer components are prefabricated, processed and marked in the factory in accordance with standardized procedures, ensuring efficient and smooth on-site assembly. Before delivery, the internal iron core and cavity undergo thorough cleaning and strict quality inspection to eliminate sundries and hidden quality troubles, ensuring every finished product meets high-standard operational requirements.

Product Use

The S11-M Fully Sealed Oil Immersed Three Phase Power Transformer is mainly used for voltage conversion and power distribution in three-phase electrical systems. It can step down high voltage to usable low voltage for factories, commercial buildings, residential areas, and public power facilities.

In industrial applications, this transformer supplies stable power to motors, production equipment, control cabinets, lighting systems, HVAC systems, and auxiliary electrical devices. Its oil-immersed structure provides efficient cooling, making it suitable for continuous operation in demanding environments.

It is also commonly used in urban and rural power grids, distribution substations, agricultural power supply systems, mining facilities, and infrastructure projects. For outdoor installations, the sealed tank design helps protect internal components from humidity, dust, and environmental changes.

As an Oil Immersed Power Transformer, it plays an important role in ensuring efficient power transmission, stable voltage output, and safe electrical operation across different power distribution networks.

Applicable Environment

The S11-M transformer is suitable for both indoor and outdoor installation, depending on project design and protection requirements. It can be used in power distribution rooms, substations, industrial plants, residential communities, agricultural areas, and outdoor transformer platforms.

It is especially suitable for environments that require stable power supply, low maintenance, and reliable insulation performance. The fully sealed oil tank helps the transformer adapt to humid, dusty, or changing outdoor conditions.

Typical applicable environments include factories, workshops, commercial buildings, residential districts, rural power grids, mining areas, construction sites, and public utility systems.

Before installation, users should consider ambient temperature, altitude, ventilation, load characteristics, protection requirements, and local electrical standards. A qualified Oil immersed power transformer manufacturer can provide technical guidance to ensure the transformer matches the actual operating environment.

Transformateur électrique de distribution de puissance triphasé extérieur de type S11-M entièrement étanche immergé dans l'huile

Lecture d'ingénierie connexe

Oil-Immersed Transformer Selection Guide · Distribution Transformer RFQ Checklist

Pour une revue d'ingénierie, contacter Shenheng Power avec le schéma unifilaire approuvé, les conditions du site, les normes requises et les exigences de livraison.

FAQs

Can a transformer convert single phase to three phase?

A standard transformer cannot directly convert single phase to three phase by itself. To convert single-phase power into three-phase power, additional equipment such as a phase converter or inverter is usually required.

How does a three phase transformer work?

A three phase transformer uses three sets of windings to transfer electrical energy between circuits through electromagnetic induction. It can step voltage up or down while maintaining three-phase power balance.

How to megger a three phase transformer?

To megger a three phase transformer, disconnect it from power, isolate all terminals, and use an insulation resistance tester to measure between windings and from windings to ground. The test should be performed by qualified electrical personnel following safety procedures.

How to size a three phase transformer?

To size a three phase transformer, calculate the total load demand in kVA, consider voltage level, load type, future expansion, and safety margin. The selected transformer capacity should match the actual operating requirements.

What are the various types of three phase transformer connections?

Common three phase transformer connections include star-star, delta-delta, star-delta, and delta-star. The choice depends on voltage requirements, grounding method, load characteristics, and system design.

What is a 3 phase oil immersed transformer?

A 3 phase oil immersed transformer is a transformer for three-phase power systems that uses insulating oil for cooling and insulation. It is widely used in industrial power distribution, substations, and utility networks.

Produits Connexes

Transformateur de puissance industriel à huile de 35 kV (moyenne et haute tension)

Transformateur de puissance industriel immergé dans l'huile 35KV BT&HT

Voir les détails
Transformateur triphasé à sec en résine moulée de 11 kV

Transformateur sec à résine coulée triphasé 11kv

Voir les détails
Transformateur triphasé à sec en résine moulée de 6 kV / 10 kV

Transformateur sec à résine coulée triphasé 6 kV / 10 kV

Voir les détails

Envoyer une demande

Formulaire de message