{"id":2018,"date":"2026-08-06T14:00:00","date_gmt":"2026-08-06T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/withdrawable-lv-switchgear-service-access\/"},"modified":"2026-08-06T14:00:00","modified_gmt":"2026-08-06T06:00:00","slug":"withdrawable-lv-switchgear-service-access","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/vi\/blog\/withdrawable-lv-switchgear-service-access\/","title":{"rendered":"T\u1ee7 \u0111i\u1ec7n h\u1ea1 th\u1ebf r\u00fat k\u00e9o \u0111\u01b0\u1ee3c: L\u1eadp k\u1ebf ho\u1ea1ch ti\u1ebfp c\u1eadn b\u1ea3o tr\u00ec cho nh\u00e0 m\u00e1y"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Plant teams specifying <strong>withdrawable switchgear<\/strong> for LV distribution must plan compartment access, interlocking, and spare-drawer logistics \u2014 not only busbar ratings \u2014 before locking GGD\/MNS-style board layouts.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This withdrawable switchgear guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>withdrawable-lv-switchgear-service-access<\/code> \u2014 n\u00f3 kh\u00f4ng thay th\u1ebf \u0111\u01b0\u1ee3c s\u1ef1 ch\u1ea5p thu\u1eadn c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c ho\u1eb7c chuy\u00ean gia t\u01b0 v\u1ea5n.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"withdrawable switchgear planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Service-access-as-a-design-requirement-,-not-an-afterthought\">Part 1. Service access as a design requirement, not an afterthought<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Withdrawable-Switchgear-inputs-to-lock-early\">Part 2. Withdrawable Switchgear inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Interlocks-,-shutters-,-and-segregation-boundaries\">Part 3. Interlocks, shutters, and segregation boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Service-access-items-to-embed-in-the-LV-board-RFQ\">Part 4. Service-access items to embed in the LV board RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-FAT-and-site-drills-before-live-racking\">Part 5. FAT and site drills before live racking<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Withdrawable-Switchgear-catalog-starting-point\">Part 6. Withdrawable Switchgear catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Access-planning-mistakes-on-LV-boards\">Part 7. Access planning mistakes on LV boards<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Service-access-as-a-design-requirement-,-not-an-afterthought\">Part 1. Service access as a design requirement, not an afterthought<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Withdrawable designs speed feeder maintenance when aisles, lifting, and interlocks are designed in. Crowded rooms that only fit the cabinet footprint often block safe racking later.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Capture maintenance philosophy in the RFQ: expected racking frequency, spare drawer storage, and whether live-compartment work rules apply on site.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u1ecdc th\u00eam: <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/mns-withdrawable-switchgear-maintenance-access\/\">MNS withdrawable switchgear maintenance access<\/a> v\u00e0 <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/ggd-vs-mns-lv-switchgear-comparison\/\">GGD vs MNS LV switchgear comparison<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Withdrawable-Switchgear-inputs-to-lock-early\">Part 2. Withdrawable Switchgear inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Access input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Plant impact if missed<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ch\u1ee7 s\u1edf h\u1eefu<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Form of separation \/ internal segregation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe maintenance zones<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spec \/ IEC form<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Withdrawable vs fixed feeders map<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong cubicle type ordered<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">M\u1ed9t d\u00f2ng<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aisle width and door swing<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Blocked racking<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Layout \/ civil<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and shutter requirements<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Racking incidents<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ops \/ manufacturer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc \/ short-circuit withstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Personnel risk<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spare drawer \/ module list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Long outage on failure<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Maintenance planner<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and gland plates<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rear access conflicts<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thi\u1ebft k\u1ebf c\u00e1p<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"withdrawable switchgear specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Quan tr\u1ecdng:<\/strong> For withdrawable switchgear, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">Th\u1ef1c ti\u1ec5n ti\u00eau chu\u1ea9n IEC<\/a> v\u00e0 c\u00e1c ghi ch\u00fa ngu\u1ed3n c\u1ee7a c\u01a1 quan ph\u1ee5 tr\u00e1ch d\u1ef1 \u00e1n.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Interlocks-,-shutters-,-and-segregation-boundaries\">Part 3. Interlocks, shutters, and segregation boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Document racking interlocks so drawers cannot be inserted or withdrawn under unsafe conditions. Shutters should cover live parts when a module is removed.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Internal segregation (form of separation) must match the maintenance rules used by the plant \u2014 higher forms reduce exposure but change cost and footprint.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Service-access-items-to-embed-in-the-LV-board-RFQ\">Part 4. Service-access items to embed in the LV board RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">M\u1ee5c \u0111\u00edch<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">G\u1eedi k\u00e8m tr\u00edch d\u1eabn<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Feeder withdrawable\/fixed matrix<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle type clarity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Form of separation requirement<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Maintenance safety<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 specification<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aisle \/ access GA constraints<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room fit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 layout annex<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock description<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe racking<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spare module list + lead times<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Outage planning<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 commercial<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">FAT racking demonstration plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Witness checklist<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 contract<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nameplate + setting sheets<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning file<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u00ednh k\u00e8m b\u1ea3ng n\u00e0y v\u00e0o m\u1ecdi b\u1ea3n s\u1eeda \u0111\u1ed5i RFQ \u0111\u1ec3 nh\u00e0 cung c\u1ea5p tr\u1ea3 v\u1ec1 c\u00e1c g\u00f3i k\u1ef9 thu\u1eadt c\u00f3 th\u1ec3 so s\u00e1nh \u0111\u01b0\u1ee3c thay v\u00ec c\u00e1c \u0111o\u1ea1n tr\u00edch t\u1eeb catalogue.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-FAT-and-site-drills-before-live-racking\">Part 5. FAT and site drills before live racking<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Witness mechanical racking, shutter operation, and interlock defeat attempts during FAT when the contract requires it. On site, train operators on the approved sequence before the first live racking event.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Store spare drawers in labeled locations with matching ratings \u2014 mismatched spares create false confidence during emergencies.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Withdrawable-Switchgear-catalog-starting-point\">Part 6. Withdrawable Switchgear catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many withdrawable switchgear scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/vi\/product\/industrial-lv-power-switchgear-ggd-ggj-mns-low-voltage-metal-enclosed-switchgear\/\">GGD \/ GGJ \/ MNS low voltage metal-enclosed switchgear<\/a> m\u1ee5c danh m\u1ee5c \u0111\u01b0\u1ee3c ghi l\u1ea1i tr\u00ean trang s\u1ea3n ph\u1ea9m.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"GGD \/ GGJ \/ MNS low voltage metal-enclosed switchgear for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Gi\u1edbi h\u1ea1n \u1ee9ng d\u1ee5ng:<\/strong> Cho <code>withdrawable switchgear<\/code> (<code>withdrawable-lv-switchgear-service-access<\/code>), h\u00e3y xem trang danh m\u1ee5c \u0111\u01b0\u1ee3c li\u00ean k\u1ebft ch\u1ec9 l\u00e0 \u0111i\u1ec3m kh\u1edfi \u0111\u1ea7u k\u1ef9 thu\u1eadt. <strong>kh\u00f4ng<\/strong> \u0110\u00f3ng b\u0103ng <code>withdrawable switchgear<\/code> mua s\u1eafm khi nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1 d\u1ef1 \u00e1n, gi\u1ea3m c\u00f4ng su\u1ea5t do \u0111\u1ed9 cao, ho\u1eb7c gi\u1edbi h\u1ea1n ph\u00ea duy\u1ec7t lo\u1ea1i c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c v\u01b0\u1ee3t qu\u00e1 c\u00e1c \u0111\u1ecbnh m\u1ee9c \u0111\u00e3 c\u00f4ng b\u1ed1 tr\u00ean trang s\u1ea3n ph\u1ea9m \u0111\u00f3.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the withdrawable switchgear study points to a different scheme or rating for withdrawable-lv-switchgear-service-access, browse the <a href=\"https:\/\/shenhengglobal.com\/vi\/low-voltage-switchgear\/\">trang danh m\u1ee5c<\/a> v\u00e0 g\u1eedi c\u00e1c t\u00e0i li\u1ec7u h\u1ecdc t\u1eadp qua <a href=\"https:\/\/shenhengglobal.com\/vi\/contact-us\/\">Li\u00ean h\u1ec7 \u0110i\u1ec7n l\u1ef1c Th\u00e2m H\u1eb1ng<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Access-planning-mistakes-on-LV-boards\">Part 7. Access planning mistakes on LV boards<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Designing only for cabinet footprint without racking aisle clearance.<\/li>\n<li style=\"margin:0 0 8px\">Ordering all feeders withdrawable when many rarely need racking.<\/li>\n<li style=\"margin:0 0 8px\">Omitting spare module ratings from the RFQ.<\/li>\n<li style=\"margin:0 0 8px\">Skipping interlock demonstrations at FAT.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before operator racking drills are recorded.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">C\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">What aisle width do withdrawable LV boards need?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Enough clear space for safe racking and door swing per the manufacturer GA and plant HSE rules \u2014 measure the room, do not assume.<\/p>\n<h3 style=\"margin:28px 0 12px\">How do interlocks protect racking operations?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">They prevent insertion\/withdrawal under unsafe breaker or shutter states; verify the logic against the ops procedure.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is fixed versus withdrawable preferred?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fixed feeders suit rarely maintained circuits; withdrawable suits feeders that need fast module swap under a planned maintenance philosophy.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which arc and segregation notes belong on the GA?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Short-circuit withstand, form of separation, and any arc claims should appear on controlled drawings.<\/p>\n<h3 style=\"margin:28px 0 12px\">What spare drawer strategy should RFQs include?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">List critical feeder ratings, quantities, and lead times so outages are not limited by missing modules.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which FAT checks prove service access before shipment?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mechanical racking, shutter coverage, and interlock demonstrations agreed in the FAT plan.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439 low-voltage switchgear assemblies<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE LV distribution equipment references<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>L\u1eadp k\u1ebf ho\u1ea1ch b\u1ea3o d\u01b0\u1ee1ng t\u1ee7 \u0111\u00f3ng c\u1eaft h\u1ea1 th\u1ebf c\u00f3 th\u1ec3 r\u00fat k\u00e9o (v\u1edbi b\u1ed1 tr\u00ed ng\u0103n t\u1ee7, c\u01a1 c\u1ea5u li\u00ean \u0111\u1ed9ng, gi\u1edbi h\u1ea1n h\u1ed3 quang v\u00e0 t\u00e0i li\u1ec7u RFQ cho t\u1ee7 \u0111i\u1ec7n c\u00f4ng nghi\u1ec7p GGD\/MNS).<\/p>","protected":false},"author":1,"featured_media":1381,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/comments?post=2018"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/2018\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media\/1381"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media?parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/categories?post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/tags?post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}