{"id":1998,"date":"2026-08-03T14:00:00","date_gmt":"2026-08-03T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/load-break-switch-rmu-selection-guide\/"},"modified":"2026-08-03T14:00:00","modified_gmt":"2026-08-03T06:00:00","slug":"load-break-switch-rmu-selection-guide","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/vi\/blog\/load-break-switch-rmu-selection-guide\/","title":{"rendered":"Dao c\u1eaft t\u1ea3i RMU: H\u01b0\u1edbng d\u1eabn l\u1ef1a ch\u1ecdn v\u00f2ng c\u00e1\u0628"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Network planners selecting a <strong>load break switch<\/strong> inside an RMU must separate normal load switching duty from fault-making and fuse\/breaker protection roles before comparing outdoor cable-ring quotations.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This load break switch guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>load-break-switch-rmu-selection-guide<\/code> \u2014 n\u00f3 kh\u00f4ng thay th\u1ebf \u0111\u01b0\u1ee3c s\u1ef1 ch\u1ea5p thu\u1eadn c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c ho\u1eb7c chuy\u00ean gia t\u01b0 v\u1ea5n.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"load break switch planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Part 1. Load break duty versus protection roles on cable rings<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Load-Break-Switch-inputs-to-lock-early\">Part 2. Load Break Switch inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Part 3. Outdoor cable entry, grounding, and gas handling<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-RMU-RFQ-pack-for-load-break-applications\">Part 4. RMU RFQ pack for load break applications<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Commissioning-checks-before-ring-energization\">Part 5. Commissioning checks before ring energization<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Load-Break-Switch-catalog-starting-point\">Part 6. Load Break Switch catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Part 7. Buyer mistakes on load break RMU orders<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Part 1. Load break duty versus protection roles on cable rings<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A load break switch is sized for switching load current under defined conditions \u2014 it is not automatically a short-circuit interrupter. Ring schemes often combine load break ways with fuse-switch or circuit-breaker functions on transformer feeders.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Write the functional role of each way on the single-line so vendors cannot substitute a look-alike cubicle with the wrong duty class.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u1ecdc th\u00eam: <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/ring-main-unit-rmu-selection-guide\/\">ring main unit RMU selection guide<\/a> v\u00e0 <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/outdoor-ring-main-unit-cable-entry-planning\/\">outdoor ring main unit cable entry planning<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Load-Break-Switch-inputs-to-lock-early\">Part 2. Load Break Switch inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Selection input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Network risk if vague<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ch\u1ee7 s\u1edf h\u1eefu<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated voltage \/ insulation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong clearance class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Network SLD<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Load break current rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe switching duty<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Operating study<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-time \/ fault-making rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle damage on faults<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Number of ring \/ tee ways<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong enclosure footprint<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Feeder plan<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable type and entry direction<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil trench rework<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thi\u1ebft k\u1ebf c\u00e1p<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SF6 \/ alternative gas notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Handling &amp; environmental compliance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">HSE \/ ops<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Motorization \/ remote control<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SCADA interface gap<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Automation team<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"load break switch specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Quan tr\u1ecdng:<\/strong> For load break switch, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">Th\u1ef1c ti\u1ec5n ti\u00eau chu\u1ea9n IEC<\/a> v\u00e0 c\u00e1c ghi ch\u00fa ngu\u1ed3n c\u1ee7a c\u01a1 quan ph\u1ee5 tr\u00e1ch d\u1ef1 \u00e1n.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Part 3. Outdoor cable entry, grounding, and gas handling<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Outdoor RMUs need gland plates and bending radii that match MV cable specs. Grounding continuity between tank, cable screens, and the earthing grid should be verified before backfill.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If SF6 is used, retain handling, leak-check, and end-of-life recovery notes in the O&amp;M pack \u2014 treat them as controlled environmental documents.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-RMU-RFQ-pack-for-load-break-applications\">Part 4. RMU RFQ pack for load break applications<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">M\u1ee5c<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">M\u1ee5c \u0111\u00edch<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">G\u1eedi k\u00e8m tr\u00edch d\u1eabn<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Way function matrix (LBS \/ fuse \/ CB)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Duty clarity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated currents and fault duties<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Network match<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 study refs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry GA and gland schedule<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">C\u00f3 \u2014 tr\u01b0\u1edbc PO<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gas type and handling procedure<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">HSE compliance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 with O&amp;M<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and earthing notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe operation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops sign-off<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Routine test certificates<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Factory evidence<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 FAT list<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Remote \/ motor option datasheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SCADA integration<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">If specified<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u00ednh k\u00e8m b\u1ea3ng n\u00e0y v\u00e0o m\u1ecdi b\u1ea3n s\u1eeda \u0111\u1ed5i RFQ \u0111\u1ec3 nh\u00e0 cung c\u1ea5p tr\u1ea3 v\u1ec1 c\u00e1c g\u00f3i k\u1ef9 thu\u1eadt c\u00f3 th\u1ec3 so s\u00e1nh \u0111\u01b0\u1ee3c thay v\u00ec c\u00e1c \u0111o\u1ea1n tr\u00edch t\u1eeb catalogue.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Commissioning-checks-before-ring-energization\">Part 5. Commissioning checks before ring energization<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Verify mechanical operation of each load break way, earthing switch position indications, and cable sheath bonds. Record gas pressure (where applicable) against the nameplate band.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Do not close onto a live ring until protection on tee-offs is proven and the operating sequence is filed with the control room.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Load-Break-Switch-catalog-starting-point\">Part 6. Load Break Switch catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many load break switch scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/vi\/product\/ring-main-unit-rmu-sf6-gas-insulated-mv-switchgear\/\">SF6 gas insulated ring main unit (RMU)<\/a> m\u1ee5c danh m\u1ee5c \u0111\u01b0\u1ee3c ghi l\u1ea1i tr\u00ean trang s\u1ea3n ph\u1ea9m.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"SF6 gas insulated ring main unit (RMU) for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Gi\u1edbi h\u1ea1n \u1ee9ng d\u1ee5ng:<\/strong> Cho <code>load break switch<\/code> (<code>load-break-switch-rmu-selection-guide<\/code>), h\u00e3y xem trang danh m\u1ee5c \u0111\u01b0\u1ee3c li\u00ean k\u1ebft ch\u1ec9 l\u00e0 \u0111i\u1ec3m kh\u1edfi \u0111\u1ea7u k\u1ef9 thu\u1eadt. <strong>kh\u00f4ng<\/strong> \u0110\u00f3ng b\u0103ng <code>load break switch<\/code> mua s\u1eafm khi nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1 d\u1ef1 \u00e1n, gi\u1ea3m c\u00f4ng su\u1ea5t do \u0111\u1ed9 cao, ho\u1eb7c gi\u1edbi h\u1ea1n ph\u00ea duy\u1ec7t lo\u1ea1i c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c v\u01b0\u1ee3t qu\u00e1 c\u00e1c \u0111\u1ecbnh m\u1ee9c \u0111\u00e3 c\u00f4ng b\u1ed1 tr\u00ean trang s\u1ea3n ph\u1ea9m \u0111\u00f3.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the load break switch study points to a different scheme or rating for load-break-switch-rmu-selection-guide, browse the <a href=\"https:\/\/shenhengglobal.com\/vi\/medium-voltage-switchgear\/\">trang danh m\u1ee5c<\/a> v\u00e0 g\u1eedi c\u00e1c t\u00e0i li\u1ec7u h\u1ecdc t\u1eadp qua <a href=\"https:\/\/shenhengglobal.com\/vi\/contact-us\/\">Li\u00ean h\u1ec7 \u0110i\u1ec7n l\u1ef1c Th\u00e2m H\u1eb1ng<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Part 7. Buyer mistakes on load break RMU orders<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Treating every RMU way as a fault interrupter.<\/li>\n<li style=\"margin:0 0 8px\">Leaving feeder count as &#8220;typical three-way&#8221; without a locked matrix.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring cable entry direction until the pad is poured.<\/li>\n<li style=\"margin:0 0 8px\">Omitting SF6 handling documents from the contract annex.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before earthing indications are verified.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">C\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">How does a load break switch differ from a fault-making switch?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Load break covers defined load-current switching; fault-making and interrupting duties require ratings proven for short-circuit conditions.<\/p>\n<h3 style=\"margin:28px 0 12px\">What feeder count should buyers freeze on an RMU RFQ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Freeze ring and tee ways on a function matrix tied to the network plan before requesting enclosure GA drawings.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is SF6 RMU preferred for outdoor cable rings?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">When compact outdoor footprints and proven gas-insulated modules fit the site \u2014 still subject to local environmental handling rules.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which fault ratings must match the network study?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Short-time withstand and any fault-making claims must match prospective fault levels at the installation point.<\/p>\n<h3 style=\"margin:28px 0 12px\">What cable entry details stall outdoor RMU installs?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Gland plate size, entry direction, and bending radius mismatches with trenches or ducts.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which documents should accompany SF6 handling notes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Leak-check procedures, recovery requirements, and O&amp;M references should travel with the equipment dossier.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271 switchgear publications<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE distribution switchgear references<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Select a load break switch RMU with feeder count, fault duty, cable entry design, SF6 handling notes, and RFQ documents for MV cable ring networks.<\/p>","protected":false},"author":1,"featured_media":1394,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1998","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/comments?post=1998"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1998\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media\/1394"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media?parent=1998"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/categories?post=1998"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/tags?post=1998"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}