{"id":1985,"date":"2026-07-30T14:00:00","date_gmt":"2026-07-30T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/24kv-gas-insulated-switchgear-spec-checklist\/"},"modified":"2026-07-30T14:00:00","modified_gmt":"2026-07-30T06:00:00","slug":"24kv-gas-insulated-switchgear-spec-checklist","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/vi\/blog\/24kv-gas-insulated-switchgear-spec-checklist\/","title":{"rendered":"T\u1ee7 \u0111i\u1ec7n c\u00e1ch \u0111i\u1ec7n kh\u00ed 24kV: Danh s\u00e1ch ki\u1ec3m tra th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt d\u00e0nh cho ng\u01b0\u1eddi mua"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Buyers writing a <strong>24kv switchgear<\/strong> package for industrial feeders, utility rings, or renewable collector nodes need a disciplined checklist before quotations diverge on incomplete ratings.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This article turns common tender gaps into a practical GIS specification sequence. Use it with your approved single-line diagram and fault study &#8212; not as a substitute for project engineering sign-off.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"24kv switchgear lineup overview for specification planning\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Why-a-24kV-checklist-matters-before-award\">Part 1. Why a 24kV checklist matters before award<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Core-electrical-and-environmental-inputs\">Part 2. Core electrical and environmental inputs<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Application-boundaries-for-24kV-GIS-boards\">Part 3. Application boundaries for 24kV GIS boards<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Documentation-and-RFQ-checklist\">Ph\u1ea7n 4. T\u00e0i li\u1ec7u v\u00e0 danh m\u1ee5c ki\u1ec3m tra RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Factory-tests-,-site-checks-,-and-gas-handling-notes\">Part 5. Factory tests, site checks, and gas handling notes<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Product-recommendation-and-Fit-Boundary\">Ph\u1ea7n 6. \u0110\u1ec1 xu\u1ea5t s\u1ea3n ph\u1ea9m v\u00e0 Ranh gi\u1edbi ph\u00f9 h\u1ee3p<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Common-buyer-mistakes\">Ph\u1ea7n 7. C\u00e1c sai l\u1ea7m ph\u1ed5 bi\u1ebfn c\u1ee7a ng\u01b0\u1eddi mua<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Why-a-24kV-checklist-matters-before-award\">Part 1. Why a 24kV checklist matters before award<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Late change orders often start with an RFQ that names &#8220;24kV GIS&#8221; without locking insulation level, busbar continuous current, or short-time withstand. Vendors then fill gaps differently, and technical clarification cycles consume the delivery window.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A written checklist forces the same rating language across every bidder. It also gives civil, protection, and commissioning teams a shared reference while outline drawings are still provisional.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Related reading on board architecture appears in the <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/kyn28-gas-insulated-switchgear-buyers-guide\/\">KYN28 gas insulated switchgear buyer guide<\/a> and the <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/medium-voltage-gas-insulated-switchgear-components\/\">medium voltage GIS components overview<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Core-electrical-and-environmental-inputs\">Part 2. Core electrical and environmental inputs<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Capture these fields before normalizing prices:<\/p>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Spec field<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Why it belongs on the RFQ<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ngu\u1ed3n \u0111i\u1ec3n h\u00ecnh<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated voltage \/ Um<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sets insulation class and cubicle design basis<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Approved single-line<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Power frequency and lightning impulse levels<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Defines dielectric margins<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Utility or consultant note<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Busbar continuous current<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Drives thermal design and feeder grouping<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nghi\u00ean c\u1ee9u t\u1ea3i tr\u1ecdng<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-time \/ peak withstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Locks bracing and breaker duty<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Internal arc classification request<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Clarifies operator exposure assumptions<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safety philosophy<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ambient, altitude, pollution degree<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Triggers derating and enclosure choices<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">B\u1ea3ng d\u1eef li\u1ec7u trang web<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and CT\/VT ratios<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aligns terminations and metering<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection scheme<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"24kv switchgear rating table review during RFQ normalization\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Also record service continuity needs, withdrawable versus fixed breaker preference, and whether remote racking or motorized disconnects are mandatory. Leaving those as &#8220;vendor standard&#8221; invites unequal offers.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Application-boundaries-for-24kV-GIS-boards\">Part 3. Application boundaries for 24kV GIS boards<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A 24kV class is often selected when feeder density, cable length, or utility interface points make a lower MV class impractical. Compact GIS footprints help indoor substations and containerized collector stations where aisle width is limited.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Outdoor ring schemes may still prefer sealed RMU architectures rather than a full indoor GIS lineup. Compare those boundaries against the <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/mv-vs-lv-switchgear-key-differences\/\">MV vs LV switchgear differences guide<\/a> when the project straddles distribution and plant LV boards.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Corrosive, dusty, or high-altitude sites need explicit derating notes. Harmonic-rich industrial loads may require additional CT accuracy or relay coordination inputs before the protection philosophy is frozen.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Documentation-and-RFQ-checklist\">Ph\u1ea7n 4. T\u00e0i li\u1ec7u v\u00e0 danh m\u1ee5c ki\u1ec3m tra RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">T\u00e0i li\u1ec7u \/ v\u1eadt ph\u1ea9m<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">M\u1ee5c \u0111\u00edch<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Khi n\u00e0o n\u00ean y\u00eau c\u1ea7u<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Type \/ routine test summary<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Confirms dielectric and temperature-rise basis<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tr\u01b0\u1edbc \u0111\u01a1n \u0111\u1eb7t h\u00e0ng<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">GA drawing and shipping weights<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil pads, lifting, and aisle clearance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Design freeze<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Single-line and wiring diagrams<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Termination, interlocking, and relay mapping<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Before manufacturing release<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gas monitoring I\/O list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Density alarms, trending, and SCADA points<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Design review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and earthing sequence<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe isolation workflow<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">FAT planning<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">O&amp;M manual and spare parts list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Site training and holding stock<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0110\u00e0m ph\u00e1n h\u1ee3p \u0111\u1ed3ng<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Danh s\u00e1ch ki\u1ec3m tra b\u00e0n giao v\u1eadn h\u00e0nh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Insulation, timing, and functional tests<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tr\u01b0\u1edbc khi \u0111\u00f3ng \u0111i\u1ec7n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Attach the table to every RFQ revision so suppliers return comparable technical packages instead of marketing summaries.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Factory-tests-,-site-checks-,-and-gas-handling-notes\">Part 5. Factory tests, site checks, and gas handling notes<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Factory acceptance should prove dielectric integrity, functional interlocking, mechanism timing, and gas density alarm channels against the approved drawings. Witness points belong in the purchase order &#8212; not in a late email.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">On site, verify grounding continuity, cable bending radius, torque records, and nameplate data against the revision that was released for manufacture. Gas handling procedures, cylinder logistics, and leak-check tools should be planned before the board arrives.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Maintenance access for density gauges, cable compartments, and withdrawable breakers needs to be designed into the room layout. Crowded aisles turn routine checks into outage risks.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Product-recommendation-and-Fit-Boundary\">Ph\u1ea7n 6. \u0110\u1ec1 xu\u1ea5t s\u1ea3n ph\u1ea9m v\u00e0 Ranh gi\u1edbi ph\u00f9 h\u1ee3p<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many indoor 24kV distribution scopes, start engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/vi\/product\/customized-gas-insulated-switchgear-kyn28-12-12kv-24kv-switchgear-system\/\">12kV\/24kV medium voltage switchgear<\/a> catalog entry. The product page documents a 12kV\/24kV medium voltage switchgear scope that buyers can use as a structured RFQ baseline.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"12kV\/24kV medium voltage switchgear for 24kV GIS engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/4.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Kh\u1edbp ranh gi\u1edbi:<\/strong> This recommendation supports typical industrial and utility distribution boards described on the product page. It is <strong>kh\u00f4ng<\/strong> a substitute for project-specific studies when unusual fault levels, outdoor primary GIS yards, or national utility type-approval rules apply.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the study points to an outdoor RMU scheme or a different voltage class, browse the <a href=\"https:\/\/shenhengglobal.com\/vi\/medium-voltage-switchgear\/\">thi\u1ebft b\u1ecb \u0111\u00f3ng c\u1eaft trung th\u1ebf<\/a> v\u00e0 g\u1eedi c\u00e1c t\u00e0i li\u1ec7u h\u1ecdc t\u1eadp qua <a href=\"https:\/\/shenhengglobal.com\/vi\/contact-us\/\">Li\u00ean h\u1ec7 \u0110i\u1ec7n l\u1ef1c Th\u00e2m H\u1eb1ng<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Common-buyer-mistakes\">Ph\u1ea7n 7. C\u00e1c sai l\u1ea7m ph\u1ed5 bi\u1ebfn c\u1ee7a ng\u01b0\u1eddi mua<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Comparing prices without identical short-time duty, insulation level, and test-report temperature bases.<\/li>\n<li style=\"margin:0 0 8px\">Omitting gas density alarm points and SCADA I\/O from the RFQ.<\/li>\n<li style=\"margin:0 0 8px\">Accepting &#8220;standard interlocks&#8221; without a written isolation sequence.<\/li>\n<li style=\"margin:0 0 8px\">Freezing civil pads before shipping weights and cable entry heights are confirmed.<\/li>\n<li style=\"margin:0 0 8px\">Energizing after partial FAT when density alarm channels were never witnessed.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">C\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">What ratings belong on a 24kV switchgear RFQ first?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Start with rated voltage, insulation levels, busbar continuous current, short-time and peak withstand, and the environmental conditions that drive derating.<\/p>\n<h3 style=\"margin:28px 0 12px\">How do busbar and short-time withstand values interact?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Continuous current sizes thermal capacity under normal load, while short-time and peak values size mechanical bracing and device duty during faults. Both must appear on the same revision.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which gas monitoring fields should buyers request?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Ask for density or pressure alarm setpoints, contact outputs or communication points, and any trending or lockout logic required by the protection philosophy.<\/p>\n<h3 style=\"margin:28px 0 12px\">What interlock proofs belong in factory acceptance tests?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Witness earthing, racking, door, and breaker interlocking against the approved sequence, including any remote or motorized operations specified in the RFQ.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which drawings and test reports should ship with the board?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Request GA drawings, wiring diagrams, routine test reports, gas monitoring lists, O&amp;M manuals, and spare parts lists aligned to the purchase-order revision.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is a 24kV class preferred over a lower MV class?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Projects often move to 24kV when feeder reach, interface voltage, or load growth make lower classes inefficient &#8212; confirm the choice with the utility interconnection note and cable study.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/6670\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271-1 high-voltage switchgear &#8212; common specifications<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/6679\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271-200 AC metal-enclosed switchgear up to 52 kV<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Use this 24kV switchgear GIS checklist to lock ratings, busbars, short-time duty, gas alarms, interlocks, factory tests, and RFQ documents before award.<\/p>","protected":false},"author":1,"featured_media":1389,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1985","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/comments?post=1985"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1985\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media\/1389"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media?parent=1985"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/categories?post=1985"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/tags?post=1985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}