{"id":1984,"date":"2026-08-02T14:00:00","date_gmt":"2026-08-02T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/12kv-metal-clad-switchgear-layout-checklist\/"},"modified":"2026-08-02T14:00:00","modified_gmt":"2026-08-02T06:00:00","slug":"12kv-metal-clad-switchgear-layout-checklist","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/vi\/blog\/12kv-metal-clad-switchgear-layout-checklist\/","title":{"rendered":"T\u1ee7 \u0111i\u1ec7n b\u1ecdc kim lo\u1ea1i 12kV: Danh m\u1ee5c ki\u1ec3m tra b\u1ed1 tr\u00ed cho ph\u00f2ng trung th\u1ebf"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Project engineers laying out <strong>12kV metal clad switchgear<\/strong> need more than a catalog cubicle count \u2014 cable entry, busbar rating, arc boundaries, and relay interfaces must fit the approved single-line and room geometry.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This 12kv metal clad switchgear guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>12kv-metal-clad-switchgear-layout-checklist<\/code> \u2014 n\u00f3 kh\u00f4ng thay th\u1ebf \u0111\u01b0\u1ee3c s\u1ef1 ch\u1ea5p thu\u1eadn c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c ho\u1eb7c chuy\u00ean gia t\u01b0 v\u1ea5n.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"12kv metal clad switchgear planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/4.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Why-layout-freezes-before-commercial-award\">Part 1. Why layout freezes before commercial award<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-12Kv-Metal-Clad-Switchgear-inputs-to-lock-early\">Part 2. 12Kv Metal Clad Switchgear inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Room-geometry-,-cable-routes-,-and-arc-boundaries\">Part 3. Room geometry, cable routes, and arc boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Drawings-and-data-to-require-with-each-panel-RFQ\">Part 4. Drawings and data to require with each panel RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Factory-acceptance-and-site-racking-checks\">Part 5. Factory acceptance and site racking checks<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-12Kv-Metal-Clad-Switchgear-catalog-starting-point\">Part 6. 12Kv Metal Clad Switchgear catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Layout-mistakes-that-force-rework\">Part 7. Layout mistakes that force rework<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Why-layout-freezes-before-commercial-award\">Part 1. Why layout freezes before commercial award<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Metal clad boards define aisle widths, pressure relief paths, and maintenance access for decades. Changing cable entry after manufacture often forces civil and protection rework.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Treat the layout checklist as a design control document: every revision must reconcile feeder names, CT ratios, and interlocking notes with the latest single-line revision.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u1ecdc th\u00eam: <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/metal-clad-switchgear-arc-mitigation-overview\/\">metal clad switchgear arc mitigation overview<\/a> v\u00e0 <a href=\"https:\/\/shenhengglobal.com\/vi\/blog\/kyn28-switchgear-interlock-verification\/\">Ki\u1ec3m tra li\u00ean kh\u00f3a t\u1ee7 \u0111i\u1ec7n KYN28<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-12Kv-Metal-Clad-Switchgear-inputs-to-lock-early\">Part 2. 12Kv Metal Clad Switchgear inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Layout input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Failure mode if omitted<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ch\u1ee7 s\u1edf h\u1eefu<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated voltage \/ insulation level<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong clearance class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">S\u01a1 \u0111\u1ed3 \u0111\u01a1n tuy\u1ebfn<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Main busbar continuous rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thermal overload on future feeders<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Load schedule<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-time withstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Busbar bracing inadequacy<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry (rear \/ bottom \/ side)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil trench mismatch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thi\u1ebft k\u1ebf c\u00e1p<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc classification \/ relief path<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe personnel aisle<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection \/ safety<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">CT\/VT and relay interface list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection settings delay<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">K\u1ef9 s\u01b0 r\u01a1-le<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and earthing switch notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe racking sequences<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ops \/ manufacturer<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"12kv metal clad switchgear specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/5.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Quan tr\u1ecdng:<\/strong> For 12kv metal clad switchgear, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">Th\u1ef1c ti\u1ec5n ti\u00eau chu\u1ea9n IEC<\/a> v\u00e0 c\u00e1c ghi ch\u00fa ngu\u1ed3n c\u1ee7a c\u01a1 quan ph\u1ee5 tr\u00e1ch d\u1ef1 \u00e1n.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Room-geometry-,-cable-routes-,-and-arc-boundaries\">Part 3. Room geometry, cable routes, and arc boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Confirm front and rear aisle widths, door swing, and lifting height before ordering. Bottom-entry designs need trench depth and bending radius that match MV cable specs.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Arc-mitigation ducts or relief flaps must terminate outdoors or into approved zones \u2014 never into occupied corridors without a documented study.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Drawings-and-data-to-require-with-each-panel-RFQ\">Part 4. Drawings and data to require with each panel RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"B\u1ea3ng d\u1eef li\u1ec7u c\u00f3 th\u1ec3 cu\u1ed9n\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Drawing \/ data pack<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">M\u1ee5c \u0111\u00edch<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">G\u1eedi k\u00e8m tr\u00edch d\u1eabn<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle arrangement GA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room and aisle fit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 with revision<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Single-line with CT\/VT ratios<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ph\u1ed1i h\u1ee3p b\u1ea3o v\u1ec7<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked revision<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and gland plate detail<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Trench \/ tray interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">C\u00f3 \u2014 tr\u01b0\u1edbc khi s\u1ea3n xu\u1ea5t<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock logic description<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe racking sequence<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc relief path sketch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safety acceptance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 when IAC claimed<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">FAT \/ routine test plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Witness schedule<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">C\u00f3 \u2014 ph\u1ee5 l\u1ee5c h\u1ee3p \u0111\u1ed3ng<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nameplate and relay setting sheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning dossier<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">C\u00f3 \u2014 tr\u01b0\u1edbc khi giao h\u00e0ng<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0110\u00ednh k\u00e8m b\u1ea3ng n\u00e0y v\u00e0o m\u1ecdi b\u1ea3n s\u1eeda \u0111\u1ed5i RFQ \u0111\u1ec3 nh\u00e0 cung c\u1ea5p tr\u1ea3 v\u1ec1 c\u00e1c g\u00f3i k\u1ef9 thu\u1eadt c\u00f3 th\u1ec3 so s\u00e1nh \u0111\u01b0\u1ee3c thay v\u00ec c\u00e1c \u0111o\u1ea1n tr\u00edch t\u1eeb catalogue.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Factory-acceptance-and-site-racking-checks\">Part 5. Factory acceptance and site racking checks<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Witness mechanical racking, interlock defeat attempts, and primary injection where the contract requires it. On site, verify earthing switches, shutter operation, and CT polarity before first energization.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">File as-built GA revisions with the protection settings pack so future feeder additions start from evidence rather than memory.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-12Kv-Metal-Clad-Switchgear-catalog-starting-point\">Part 6. 12Kv Metal Clad Switchgear catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many 12kv metal clad switchgear scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/vi\/product\/customized-gas-insulated-switchgear-kyn28-12-12kv-24kv-switchgear-system\/\">H\u1ec7 th\u1ed1ng t\u1ee7 \u0111i\u1ec7n trung th\u1ebf KYN28-12<\/a> m\u1ee5c danh m\u1ee5c \u0111\u01b0\u1ee3c ghi l\u1ea1i tr\u00ean trang s\u1ea3n ph\u1ea9m.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"KYN28-12 medium voltage switchgear system for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Gi\u1edbi h\u1ea1n \u1ee9ng d\u1ee5ng:<\/strong> Cho <code>12kv metal clad switchgear<\/code> (<code>12kv-metal-clad-switchgear-layout-checklist<\/code>), h\u00e3y xem trang danh m\u1ee5c \u0111\u01b0\u1ee3c li\u00ean k\u1ebft ch\u1ec9 l\u00e0 \u0111i\u1ec3m kh\u1edfi \u0111\u1ea7u k\u1ef9 thu\u1eadt. <strong>kh\u00f4ng<\/strong> \u0110\u00f3ng b\u0103ng <code>12kv metal clad switchgear<\/code> mua s\u1eafm khi nghi\u00ean c\u1ee9u s\u1ef1 c\u1ed1 d\u1ef1 \u00e1n, gi\u1ea3m c\u00f4ng su\u1ea5t do \u0111\u1ed9 cao, ho\u1eb7c gi\u1edbi h\u1ea1n ph\u00ea duy\u1ec7t lo\u1ea1i c\u1ee7a c\u00f4ng ty \u0111i\u1ec7n l\u1ef1c v\u01b0\u1ee3t qu\u00e1 c\u00e1c \u0111\u1ecbnh m\u1ee9c \u0111\u00e3 c\u00f4ng b\u1ed1 tr\u00ean trang s\u1ea3n ph\u1ea9m \u0111\u00f3.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the 12kv metal clad switchgear study points to a different scheme or rating for 12kv-metal-clad-switchgear-layout-checklist, browse the <a href=\"https:\/\/shenhengglobal.com\/vi\/medium-voltage-switchgear\/\">trang danh m\u1ee5c<\/a> v\u00e0 g\u1eedi c\u00e1c t\u00e0i li\u1ec7u h\u1ecdc t\u1eadp qua <a href=\"https:\/\/shenhengglobal.com\/vi\/contact-us\/\">Li\u00ean h\u1ec7 \u0110i\u1ec7n l\u1ef1c Th\u00e2m H\u1eb1ng<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Layout-mistakes-that-force-rework\">Part 7. Layout mistakes that force rework<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Ordering cubicles before cable entry direction is frozen.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring arc relief termination into occupied spaces.<\/li>\n<li style=\"margin:0 0 8px\">Omitting CT ratio and relay model from the RFQ package.<\/li>\n<li style=\"margin:0 0 8px\">Assuming aisle width from a previous project without measuring doors.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before interlock verification is documented.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">C\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">What room clearances matter first for 12kV metal clad boards?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Front\/rear aisle, door swing, lifting height, and arc relief termination must fit the architectural layout before PO.<\/p>\n<h3 style=\"margin:28px 0 12px\">How should busbar rating map to the feeder schedule?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Size the main bus for continuous and future feeder growth documented on the load schedule, not only today&#8217;s connected load.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is rear cable entry preferred over bottom entry?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">When trench depth or bending radius cannot support bottom entry without violating cable manufacturer limits.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which arc-mitigation notes belong on the GA drawing?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Relief path, classification claim, and any duct termination outside occupied zones should appear on the controlled GA.<\/p>\n<h3 style=\"margin:28px 0 12px\">What relay and CT data must ship with the panel RFQ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">CT\/VT ratios, accuracy class, relay type, and wiring terminal maps so settings can be prepared in parallel with manufacture.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which factory tests should buyers witness before shipment?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Agree the FAT list early \u2014 typically mechanical interlocking, dielectric checks, and functional racking demonstrations.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271 metal-enclosed switchgear family<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE switchgear standards portal<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Use this 12kV metal clad switchgear layout checklist for busbar rating, cable entry, arc mitigation, relay interfaces, and RFQ drawings before panel award.<\/p>","protected":false},"author":1,"featured_media":1391,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1984","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1984","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/comments?post=1984"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/posts\/1984\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media\/1391"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/media?parent=1984"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/categories?post=1984"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/vi\/wp-json\/wp\/v2\/tags?post=1984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}