{"id":1998,"date":"2026-08-03T14:00:00","date_gmt":"2026-08-03T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/load-break-switch-rmu-selection-guide\/"},"modified":"2026-08-03T14:00:00","modified_gmt":"2026-08-03T06:00:00","slug":"load-break-switch-rmu-selection-guide","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/pt\/blog\/load-break-switch-rmu-selection-guide\/","title":{"rendered":"Interruptor de carga RMU: Guia de sele\u00e7\u00e3o para an\u00e9is de cabo"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Planejadores de redes selecionando uma <strong>interruptor de bloqueio de carga<\/strong> dentro de uma RMU, \u00e9 necess\u00e1rio separar a fun\u00e7\u00e3o normal de mudan\u00e7a de carga das fun\u00e7\u00f5es de prote\u00e7\u00e3o contra falhas e de prote\u00e7\u00e3o contra fus\u00edveis\/interruptores antes de comparar as cota\u00e7\u00f5es de cabos de rede externos.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Este guia sobre interruptores de corte de carga concentra-se nos controles pr\u00e1ticos de aquisi\u00e7\u00e3o e layout para o pacote abaixo. Use a lista de verifica\u00e7\u00e3o em conjunto com a linha \u00fanica aprovada para <code>guia-de-selecao-do-interruptor-de-parada-de-carga-rmu<\/code> \u2014 n\u00e3o substitui a aprova\u00e7\u00e3o da empresa de servi\u00e7os p\u00fablicos ou de um consultor.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Vis\u00e3o geral da planifica\u00e7\u00e3o do interruptor de bloqueio de carga\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Conte\u00fado<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Parte 1. Fun\u00e7\u00e3o de ruptura de carga versus fun\u00e7\u00f5es de prote\u00e7\u00e3o nos an\u00e9is de cabo<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Load-Break-Switch-inputs-to-lock-early\">Parte 2. Entrada do interruptor de bloqueio para bloquear a carga antecipadamente<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Parte 3. Entrada de cabos ao ar livre, aterramento e manuseio de g\u00e1s<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-RMU-RFQ-pack-for-load-break-applications\">Parte 4. Pacote de pedidos de proposta para aplica\u00e7\u00f5es de interrup\u00e7\u00e3o de carga<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Commissioning-checks-before-ring-energization\">Parte 5. Verifica\u00e7\u00f5es de comissionamento antes da energiza\u00e7\u00e3o do circuito<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Load-Break-Switch-catalog-starting-point\">Parte 6. Ponto de partida do cat\u00e1logo do interruptor de carga<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Parte 7. Erros do comprador nas encomendas de unidades de controle de carga (RMU)<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Parte 1. Fun\u00e7\u00e3o de ruptura de carga versus fun\u00e7\u00f5es de prote\u00e7\u00e3o nos an\u00e9is de cabo<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Um interruptor de carga \u00e9 dimensionado para alternar a corrente de carga sob condi\u00e7\u00f5es definidas \u2014 n\u00e3o \u00e9 automaticamente um interruptor de curto-circuito. Os sistemas de circuito el\u00e9trico frequentemente combinam as fun\u00e7\u00f5es de corte de carga com as fun\u00e7\u00f5es de fus\u00edvel-interruptor ou disjuntor nos cabe\u00e7otes dos transformadores.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Escreva a fun\u00e7\u00e3o funcional de cada fun\u00e7\u00e3o em uma \u00fanica linha, para que os fornecedores n\u00e3o possam substituir um gabinete semelhante por uma classe de fun\u00e7\u00e3o errada.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Leitura relacionada: <a href=\"https:\/\/shenhengglobal.com\/pt\/blog\/ring-main-unit-rmu-selection-guide\/\">Guia de sele\u00e7\u00e3o da unidade principal de alarme (RMU)<\/a> e <a href=\"https:\/\/shenhengglobal.com\/pt\/blog\/outdoor-ring-main-unit-cable-entry-planning\/\">Planejamento de entrada do cabo da central de ilumina\u00e7\u00e3o externa<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Load-Break-Switch-inputs-to-lock-early\">Parte 2. Entrada do interruptor de bloqueio para bloquear a carga antecipadamente<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"tabela de dados com deslocamento\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ingresso de sele\u00e7\u00e3o<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Risco da rede se for vago<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Propriet\u00e1rio<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tens\u00e3o nominal \/ isolamento<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Classifica\u00e7\u00e3o de clearance incorreta<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rede SLD<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Classifica\u00e7\u00e3o de corrente de ruptura de carga<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Fun\u00e7\u00e3o de mudan\u00e7a de canal insegura<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Estudo de opera\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Classifica\u00e7\u00e3o de curto tempo de funcionamento \/ falhas<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Danos nos compartimentos de fuga<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Estudo de faltas<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">N\u00famero de vias de anel\/taper<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ruim o espa\u00e7o ocupado pelo gabinete<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Plano de alimenta\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tipo de cabo e dire\u00e7\u00e3o de entrada<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Reabilita\u00e7\u00e3o da trincheira civil<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Design do cabo<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Observa\u00e7\u00f5es sobre SF6 \/ g\u00e1s alternativo<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Manuseio e conformidade ambiental<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">HSE \/ opera\u00e7\u00f5es<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Motoriza\u00e7\u00e3o \/ controle remoto<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Falta de compatibilidade na interface SCADA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Equipe de automa\u00e7\u00e3o<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Revis\u00e3o das especifica\u00e7\u00f5es do interruptor de bloqueio de carga\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Importante:<\/strong> Para o interruptor de corte de carga, congelar essas entradas em uma revis\u00e3o controlada antes de normalizar as propostas comerciais; altera\u00e7\u00f5es tardias se refletem nos desenhos civis, de prote\u00e7\u00e3o e de f\u00e1brica \u2014 alinhe-se com elas. <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">pr\u00e1tica das normas IEC<\/a> e as notas da fonte da autoridade do projeto.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Parte 3. Entrada de cabos ao ar livre, aterramento e manuseio de g\u00e1s<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os RMUs externos necessitam de placas de gl\u00e2ndula e raios de flex\u00e3o que correspondam \u00e0s especifica\u00e7\u00f5es do cabo MV. A continuidade de aterramento entre o tanque, as telas do cabo e a grade de aterramento deve ser verificada antes do aterramento.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Se o SF6 for utilizado, mantenha as notas de manuseio, verifica\u00e7\u00e3o de vazamentos e recupera\u00e7\u00e3o ap\u00f3s o fim da vida \u00fatil no pacote de Manuten\u00e7\u00e3o e Opera\u00e7\u00e3o \u2014 trate-as como documentos ambientais controlados.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-RMU-RFQ-pack-for-load-break-applications\">Parte 4. Pacote de pedidos de proposta para aplica\u00e7\u00f5es de interrup\u00e7\u00e3o de carga<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"tabela de dados com deslocamento\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Prop\u00f3sito<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Enviar com cita\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Matriz de fun\u00e7\u00e3o de caminho (LBS \/ fus\u00edvel \/ CB)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Clareza da obriga\u00e7\u00e3o<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 bloqueado<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Correntes nominales e fun\u00e7\u00f5es de falha<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Jogo em rede<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 \u00e1rbitros de estudo<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Plano de inser\u00e7\u00e3o do cabo GA e da gl\u00e2ndula<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interfase civil<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 antes de PO<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tipo de g\u00e1s e procedimento de manuseio<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Compliance com a HSE<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 com O&amp;M<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Notas de interliga\u00e7\u00e3o e aterramento<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Opera\u00e7\u00e3o segura<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 encerramento da opera\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Certificados de testes de rotina<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Prova da f\u00e1brica<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sim \u2014 Lista FAT<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Datasheet da op\u00e7\u00e3o de controle remoto\/motor<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Integra\u00e7\u00e3o SCADA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Se especificado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Anexe esta tabela a cada revis\u00e3o do pedido de cota\u00e7\u00e3o (RFQ) para que os fornecedores devolvam propostas t\u00e9cnicas compar\u00e1veis em vez de extractos de cat\u00e1logo.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Commissioning-checks-before-ring-energization\">Parte 5. Verifica\u00e7\u00f5es de comissionamento antes da energiza\u00e7\u00e3o do circuito<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Verifique o funcionamento mec\u00e2nico de cada dispositivo de bloqueio de carga, as indica\u00e7\u00f5es da posi\u00e7\u00e3o do interruptor de aterramento e as liga\u00e7\u00f5es da bainha do cabo. Registre a press\u00e3o do g\u00e1s (quando aplic\u00e1vel) conforme indicado na placa de identifica\u00e7\u00e3o.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">N\u00e3o se aproximem de um anel vivo at\u00e9 que a prote\u00e7\u00e3o durante os tee-offs seja comprovada e a sequ\u00eancia de opera\u00e7\u00e3o seja registrada na sala de controle.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Load-Break-Switch-catalog-starting-point\">Parte 6. Ponto de partida do cat\u00e1logo do interruptor de carga<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Para muitos casos de uso de interruptores de corte de carga, comece a an\u00e1lise de engenharia com a Shenheng Power. <a href=\"https:\/\/shenhengglobal.com\/pt\/product\/ring-main-unit-rmu-sf6-gas-insulated-mv-switchgear\/\">Unidade de distribui\u00e7\u00e3o de g\u00e1s SF6 (RMU)<\/a> entrada de cat\u00e1logo documentada na p\u00e1gina do produto.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Unidade de distribui\u00e7\u00e3o de g\u00e1s SF6 (RMU) para revis\u00e3o t\u00e9cnica\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Limites de aplica\u00e7\u00e3o:<\/strong> Para <code>interruptor de bloqueio de carga<\/code> (<code>guia-de-selecao-do-interruptor-de-parada-de-carga-rmu<\/code>), trate a p\u00e1gina de cat\u00e1logo ligada apenas como um ponto de partida de engenharia. <strong>n\u00e3o<\/strong> congelar <code>interruptor de bloqueio de carga<\/code> aquisi\u00e7\u00e3o quando o estudo de defeitos do projeto, a desclassifica\u00e7\u00e3o por altitude ou o tipo de aprova\u00e7\u00e3o da concession\u00e1ria excedem as classifica\u00e7\u00f5es publicadas nessa p\u00e1gina do produto.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Se o estudo do interruptor de corte de carga apontar para um esquema ou classifica\u00e7\u00e3o diferente para o guia de sele\u00e7\u00e3o do interruptor de corte de carga, consulte o seguinte artigo: <a href=\"https:\/\/shenhengglobal.com\/pt\/medium-voltage-switchgear\/\">p\u00e1gina de categoria<\/a> e enviar os contributos para o estudo <a href=\"https:\/\/shenhengglobal.com\/pt\/contact-us\/\">Contactar a Shenheng Power<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Parte 7. Erros do comprador nas encomendas de unidades de controle de carga (RMU)<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Considerar cada RMU como um interruptor de falha.<\/li>\n<li style=\"margin:0 0 8px\">O c\u00e1lculo do n\u00famero de alimentadores \u00e9 considerado como \u201ctipicamente um tri\u00e2ngulo\u201d sem uma matriz fechada.<\/li>\n<li style=\"margin:0 0 8px\">Ignorando a dire\u00e7\u00e3o da entrada do cabo at\u00e9 que o tamp\u00e3o seja despejado.<\/li>\n<li style=\"margin:0 0 8px\">Omiss\u00e3o dos documentos de gest\u00e3o do SF6 no anexo do contrato.<\/li>\n<li style=\"margin:0 0 8px\">A energiza\u00e7\u00e3o ocorre antes de verificar as indica\u00e7\u00f5es de aterramento.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">FAQ<\/h2>\n<h3 style=\"margin:28px 0 12px\">Como um interruptor de ruptura de carga difere de um interruptor de falha?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os disjuntores de carga possuem fun\u00e7\u00f5es de comuta\u00e7\u00e3o de carga e corrente; as fun\u00e7\u00f5es de falha e interrup\u00e7\u00e3o exigem especifica\u00e7\u00f5es comprovadas para condi\u00e7\u00f5es de curto-circuito.<\/p>\n<h3 style=\"margin:28px 0 12px\">Qual o n\u00famero de alimentadores que os compradores devem incluir em uma RFQ para RMU?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Freeze os an\u00e9is e as vias de tee numa matriz de fun\u00e7\u00f5es ligada ao plano de rede antes de solicitar os desenhos do GA do recinto.<\/p>\n<h3 style=\"margin:28px 0 12px\">Quando a SF6 RMU \u00e9 preferida para an\u00e9is de cabo externos?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Quando as dimens\u00f5es compactas e os m\u00f3dulos comprovados com isolamento por g\u00e1s se encaixam no local \u2014 ainda sujeitos \u00e0s regras locais de gest\u00e3o ambiental.<\/p>\n<h3 style=\"margin:28px 0 12px\">Que classifica\u00e7\u00f5es de falha devem corresponder ao estudo da rede?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">As resist\u00eancias de curto prazo e quaisquer reivindica\u00e7\u00f5es de falha devem corresponder aos n\u00edveis de falha previstos no local de instala\u00e7\u00e3o.<\/p>\n<h3 style=\"margin:28px 0 12px\">Quais detalhes de entrada de cabo impedem a instala\u00e7\u00e3o de RMUs ao ar livre?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">O tamanho da placa da gl\u00e2ndula, a dire\u00e7\u00e3o de entrada e o raio de curvatura n\u00e3o correspondem \u00e0s frestas ou dutos.<\/p>\n<h3 style=\"margin:28px 0 12px\">Quais documentos devem acompanhar as notas de manuseio de SF6?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os procedimentos de verifica\u00e7\u00e3o de vazamentos, os requisitos de recupera\u00e7\u00e3o e as refer\u00eancias de O&amp;M devem estar inclu\u00eddos no dossier do equipamento.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">Refer\u00eancias<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">Publica\u00e7\u00f5es IEC 62271 sobre equipamentos de comando e controle<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">Refer\u00eancias de disjuntores de distribui\u00e7\u00e3o da IEEE<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Escolha um interruptor de corte de carga RMU com n\u00famero de cabeamento, fun\u00e7\u00e3o de falha, projeto de entrada do cabo, notas sobre manuseio de SF6 e documentos de RFP para redes de cabos de anel MV.<\/p>","protected":false},"author":1,"featured_media":1394,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1998","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/posts\/1998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/comments?post=1998"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/posts\/1998\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/media\/1394"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/media?parent=1998"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/categories?post=1998"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pt\/wp-json\/wp\/v2\/tags?post=1998"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}