{"id":3610,"date":"2026-11-09T08:50:41","date_gmt":"2026-11-09T00:50:41","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3610"},"modified":"2026-11-11T09:19:50","modified_gmt":"2026-11-11T01:19:50","slug":"s13-10kv-and-20kv-oil-immersed-power-distribution-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/pl\/product\/s13-10kv-and-20kv-oil-immersed-power-distribution-transformers\/","title":{"rendered":"Transformator\u00f3w rozdzielczych olejowych S13 10kV i 20kV"},"content":{"rendered":"<h2>Przegl\u0105d produktu i zastosowanie<\/h2>\n<p>Seria S13 to w pe\u0142ni szczelne transformator\u00f3w rozdzielczych olejowych przeznaczonych do system\u00f3w AC o cz\u0119stotliwo\u015bci znamionowej 50Hz i maksymalnym napi\u0119ciu roboczym 20kV. S\u0105 one g\u0142\u00f3wnie u\u017cywane jako transformator\u00f3w rozdzielczych w r\u00f3\u017cnych przedsi\u0119biorstwach przemys\u0142owych, w tym przemys\u0142 naftowy, metalurgiczny, chemiczny, tekstylny i lekki, a tak\u017ce w miejscach z wysokim poziomem py\u0142u. Transformator\u00f3w zaprojektowane s\u0105 dla wysokiej wydajno\u015bci, niskich strat i niezawodnej pracy, co czyni je odpowiednimi zar\u00f3wno do instalacji wewn\u0119trznych, jak i zewn\u0119trznych (instalacja na zewn\u0105trz wymaga unikania bezpo\u015bredniego nas\u0142onecznienia, gaz\u00f3w korozyjnych lub py\u0142u, natomiast instalacja wewn\u0119trzna wymaga odpowiedniej przestrzeni do odprowadzania ciep\u0142a i bezpiecznego dystansu).<\/p>\n<h2>Najwa\u017cniejsze cechy i konstrukcja<\/h2>\n<p>1. Rdze\u0144: Rdze\u0144 wykonany jest z wysokiej przepuszczalno\u015bci, ziarno-orientowanej, ch\u0142odzonej na zimno stali silikonowej. Przyjmuje now\u0105 struktur\u0119 z w pe\u0142ni miterowanym, z\u0142o\u017conym rdzeniem. Cz\u0119\u015b\u0107 rdzenia ma wieloetapowy, okr\u0105g\u0142y przekr\u00f3j, a jarzmo ma taki sam przekr\u00f3j jak cz\u0119\u015b\u0107 rdzenia, co zapewnia wysok\u0105 wydajno\u015b\u0107 magnetyczn\u0105 i niskie straty bez obci\u0105\u017cenia.<\/p>\n<p>2. Uzwojenie: Uzwojenia s\u0105 zaprojektowane z falistymi kana\u0142ami olejowymi, przyjmuj\u0105c proces impregnacji bez lakieru i mocowane ta\u015bmami wi\u0105\u017c\u0105cymi. Wszystkie uzwojenia to koncentryczne cewki. Uzwojenie wysokiego napi\u0119cia wyposa\u017cone jest w odczepy odpowiadaj\u0105ce wymaganym napi\u0119ciom odczepowym, kt\u00f3re s\u0105 pod\u0142\u0105czone do prze\u0142\u0105cznika odczepowego. Prze\u0142\u0105cznik odczepowy jest zamontowany na pokrywie zbiornika, a regulacja napi\u0119cia odczepowego mo\u017ce by\u0107 wykonywana tylko po wy\u0142\u0105czeniu zasilania.<\/p>\n<p>3. Urz\u0105dzenia ochrony bezpiecze\u0144stwa: Transformator\u00f3w o mocy od 30 do 2000 kVA wyposa\u017cone s\u0105 w zaw\u00f3r bezpiecze\u0144stwa. Mo\u017cna zainstalowa\u0107 przeka\u017anik gazowy z terminalami alarmowymi i wyzwalaj\u0105cymi zgodnie z wymaganiami u\u017cytkownika.<\/p>\n<p>4. Urz\u0105dzenie pomiaru temperatury oleju: Wszystkie transformator\u00f3w wyposa\u017cone s\u0105 w gniazdo na termometr szklany, zamontowane na g\u00f3rze zbiornika oleju i si\u0119gaj\u0105ce do oleju na g\u0142\u0119boko\u015bci 120\u00b110 mm. Transformator\u00f3w o mocy od 1000 do 2000 kVA wyposa\u017cone s\u0105 w zewn\u0119trzny termometr sygna\u0142owy.<\/p>\n<p>5. Zbiornik transformatora: Zbiornik transformatora wykonany jest z falistych \u015bcian, a jego powierzchnia jest pokryta pow\u0142ok\u0105 proszkow\u0105 dla trwa\u0142ego przylegania farby. Faliste \u015bciany pe\u0142ni\u0105 podw\u00f3jn\u0105 funkcj\u0119 odprowadzania ciep\u0142a i \u201coddychania\u201d waha\u0144 obj\u0119to\u015bci oleju transformatora spowodowanych zmianami temperatury. W rezultacie w pe\u0142ni szczelny transformator eliminuje potrzeb\u0119 stosowania konserwatora oleju, co zmniejsza ca\u0142kowit\u0105 wysoko\u015b\u0107 jednostki. Podczas enkapsulacji transformatora stosuje si\u0119 nape\u0142nianie pr\u00f3\u017cniowe olejem, aby ca\u0142kowicie usun\u0105\u0107 wilgo\u0107 wewn\u0105trz transformatora. Olej transformatorowy jest izolowany od kontaktu z powietrzem, co skutecznie zapobiega dostawaniu si\u0119 tlenu i wilgoci, kt\u00f3re pogarsza\u0142yby w\u0142a\u015bciwo\u015bci izolacji i przyspiesza\u0142y starzenie oleju. Dlatego nie jest konieczne regularne badanie pr\u00f3bki oleju.<\/p>\n<p>6. Warunki pracy: Odpowiednie dla obszar\u00f3w o wysoko\u015bci nie przekraczaj\u0105cej 1000 metr\u00f3w, maksymalnej temperaturze otoczenia +40\u00b0C i minimalnej temperaturze otoczenia -25\u00b0C lub -5\u00b0C. Znamionowa cz\u0119stotliwo\u015b\u0107 zasilania wynosi 50Hz, a zakres waha\u0144 napi\u0119cia zasilania nie przekracza \u00b15% warto\u015bci znamionowej. Wska\u017anik zniekszta\u0142cenia przebiegu musi spe\u0142nia\u0107 wymagania zarz\u0105dzania harmonicznymi systemu zasilania. Transformator\u00f3w mo\u017cna instalowa\u0107 na zewn\u0105trz lub wewn\u0105trz w dobrze wentylowanych miejscach. Przy instalacji na zewn\u0105trz nale\u017cy unika\u0107 bezpo\u015bredniego nas\u0142onecznienia, gaz\u00f3w korozyjnych lub nagromadzenia py\u0142u; przy instalacji wewn\u0119trznej zapewni\u0107 odpowiedni\u0105 przestrze\u0144 do odprowadzania ciep\u0142a i bezpieczny dystans. Transformator mo\u017ce pracowa\u0107 przez d\u0142ugi czas z moc\u0105 znamionow\u0105 i ma okre\u015blon\u0105 kr\u00f3tkotrwa\u0142\u0105 zdolno\u015b\u0107 przeci\u0105\u017ceniow\u0105. W przypadku u\u017cycia w specjalnych \u015brodowiskach, takich jak obszary nara\u017cone na burze, wysok\u0105 wilgotno\u015b\u0107, du\u017ce zanieczyszczenia, korozj\u0119 chemiczn\u0105 lub strefy sejsmiczne, nale\u017cy uprzednio powiadomi\u0107 i zapewni\u0107 zwi\u0119kszone zabezpieczenia.<\/p>\n<h2>Parametry produktu<\/h2>\n<table style=\"border-collapse: collapse; width: 50.2877%; height: 604px;\" border=\"0\" width=\"648\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 54.00pt; width: 54.00pt;\" rowspan=\"4\" width=\"72\" height=\"72\">Nominalny<br \/>\nPojemno\u015b\u0107<br \/>\n(kVA)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Wysoka<br \/>\nnapi\u0119cie<br \/>\n(kV)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Wysokie napi\u0119cie<br \/>\nzakres odczep\u00f3w<br \/>\n(%)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Niskie<br \/>\nnapi\u0119cie<br \/>\n(kV)<\/td>\n<td class=\"et2\" style=\"width: 162.00pt;\" colspan=\"3\" width=\"216\">S13-M<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Brak obci\u0105\u017cenia<br \/>\npr\u0105d<br \/>\n(%)<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">zwarcie<br \/>\nimpedancja%<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" colspan=\"3\">stal ta\u015bmowa elektryczna<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td rowspan=\"2\">Strata bez obci\u0105\u017cenia kW<\/td>\n<td colspan=\"2\">Strata przy pe\u0142nym obci\u0105\u017ceniu kW<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td>Dyn11\/Yzn11<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">30<\/td>\n<td rowspan=\"19\">63<br \/>\n10<br \/>\n10.5<\/td>\n<td rowspan=\"19\">\u00b12\u00d72,5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\" align=\"right\">0.4<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">630<\/td>\n<td align=\"right\">710<\/td>\n<td align=\"right\">1.2<\/td>\n<td rowspan=\"12\" align=\"right\">4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">50<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">910<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">1.04<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">63<\/td>\n<td align=\"right\">110<\/td>\n<td align=\"right\">1090<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">80<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">1310<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">100<\/td>\n<td align=\"right\">150<\/td>\n<td align=\"right\">1580<\/td>\n<td align=\"right\">1570<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">125<\/td>\n<td align=\"right\">170<\/td>\n<td align=\"right\">1890<\/td>\n<td align=\"right\">1850<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">160<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2310<\/td>\n<td align=\"right\">2130<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">200<\/td>\n<td align=\"right\">240<\/td>\n<td align=\"right\">2730<\/td>\n<td align=\"right\">2530<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">250<\/td>\n<td align=\"right\">290<\/td>\n<td align=\"right\">3200<\/td>\n<td align=\"right\">2760<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">315<\/td>\n<td align=\"right\">340<\/td>\n<td align=\"right\">3830<\/td>\n<td align=\"right\">3470<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">400<\/td>\n<td align=\"right\">410<\/td>\n<td align=\"right\">4520<\/td>\n<td align=\"right\">3990<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">500<\/td>\n<td align=\"right\">480<\/td>\n<td align=\"right\">5410<\/td>\n<td align=\"right\">4880<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">630<\/td>\n<td align=\"right\">570<\/td>\n<td colspan=\"2\" align=\"right\">6200<\/td>\n<td align=\"right\">0.48<\/td>\n<td rowspan=\"5\" align=\"right\">4.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">800<\/td>\n<td align=\"right\">700<\/td>\n<td colspan=\"2\" align=\"right\">7500<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1000<\/td>\n<td align=\"right\">830<\/td>\n<td colspan=\"2\" align=\"right\">10300<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1250<\/td>\n<td align=\"right\">970<\/td>\n<td colspan=\"2\" align=\"right\">12000<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1600<\/td>\n<td align=\"right\">1170<\/td>\n<td colspan=\"2\" align=\"right\">14500<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2000<\/td>\n<td align=\"right\">1360<\/td>\n<td colspan=\"2\" align=\"right\">18300<\/td>\n<td align=\"right\">0.32<\/td>\n<td rowspan=\"2\" align=\"right\">5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2500<\/td>\n<td align=\"right\">1600<\/td>\n<td colspan=\"2\" align=\"right\">21200<\/td>\n<td align=\"right\">0.32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Szczeg\u00f3\u0142y zastosowania<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3861\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3862\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3863\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3864\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Seria S13 to w pe\u0142ni szczelne transformator\u00f3w olejowych przeznaczonych do system\u00f3w energetycznych o cz\u0119stotliwo\u015bci AC 50Hz i znamionowym napi\u0119ciu roboczym 20kV lub mniej. S\u0105 one u\u017cywane jako transformator\u00f3w rozdzielczych w przedsi\u0119biorstwach takich jak przemys\u0142 naftowy, metalurgiczny, chemiczny, tekstylny i lekkiego przemys\u0142u, a tak\u017ce w miejscach z du\u017c\u0105 ilo\u015bci\u0105 py\u0142u. Transformator\u00f3w wyposa\u017cone s\u0105 w wysokodost\u0119pn\u0105 rdze\u0144 z wysokiej przepuszczalno\u015bci, ziarno-orientowanej, ch\u0142odzonej na zimno stali silikonowej, zaawansowany system izolacji oraz w pe\u0142ni szczeln\u0105 konstrukcj\u0119 zbiornika oleju, zapewniaj\u0105c\u0105 bezobs\u0142ugow\u0105 prac\u0119 i d\u0142ug\u0105 \u017cywotno\u015b\u0107.<\/p>","protected":false},"featured_media":3611,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3610","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/product\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/comments?post=3610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/media\/3611"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/product_brand?post=3610"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/product_cat?post=3610"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/product_tag?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}