{"id":1698,"date":"2026-07-24T14:00:00","date_gmt":"2026-07-24T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/?p=1698"},"modified":"2026-07-24T14:00:00","modified_gmt":"2026-07-24T06:00:00","slug":"padmount-transformer-vs-compact-substation","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/pl\/blog\/padmount-transformer-vs-compact-substation\/","title":{"rendered":"Kiedy wybra\u0107 transformator s\u0142upowy zamiast kompaktowej stacji rozdzielczej"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Buyers comparing a <strong>padmount transformer<\/strong> with a compact outdoor substation need a practical way to separate equipment scope, civil interface, and documentation before quotations look interchangeable.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This guide summarizes decision steps used by EPC teams and facility engineers when they decide whether a stand-alone padmount transformer is enough, or whether a factory-assembled compact substation better matches switching, LV distribution, and schedule constraints. Use it as a procurement checklist\u2014not as a substitute for project-specific engineering approval.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Project planning overview for padmount transformer selection\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/4.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">Spis tre\u015bci<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-why-this-topic-matters-in-mv-lv-projects\">Cz\u0119\u015b\u0107 1. Dlaczego ten temat jest wa\u017cny w projektach SN-nn<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-key-specification-inputs\">Cz\u0119\u015b\u0107 2. Kluczowe dane wej\u015bciowe specyfikacji<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-application-and-operating-boundaries\">Cz\u0119\u015b\u0107 3. Zastosowanie i granice eksploatacji<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-documentation-and-rfq-checklist\">Cz\u0119\u015b\u0107 4. Dokumentacja i lista kontrolna zapytania ofertowego<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-installation-testing-or-maintenance-notes\">Cz\u0119\u015b\u0107 5. Uwagi dotycz\u0105ce instalacji, testowania lub konserwacji<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-product-recommendation-and-fit-boundary\">Cz\u0119\u015b\u0107 6. Rekomendacja produktu i Granica dopasowania<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-common-buyer-mistakes\">Cz\u0119\u015b\u0107 7. Typowe b\u0142\u0119dy kupuj\u0105cych<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#faq\">Najcz\u0119\u015bciej zadawane pytania<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#references\">Bibliografia<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-why-this-topic-matters-in-mv-lv-projects\">Cz\u0119\u015b\u0107 1. Dlaczego ten temat jest wa\u017cny w projektach SN-nn<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Distribution upgrades fail quietly when procurement teams treat catalog labels as fully engineered designs. A padmount transformer and a compact substation can both serve outdoor MV-LV conversion, yet they rarely deliver the same switching scope, cable interface, or handover package.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For padmount transformer purchases, the order should reference measurable parameters\u2014voltage class, kVA, impedance, vector group, enclosure rating, and required tests\u2014rather than marketing adjectives alone. If the single-line diagram also needs MV switching and LV distribution in one outdoor bay, a compact package may reduce site assembly risk.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Sprawd\u017a publiczne informacje na temat <a href=\"https:\/\/shenhengglobal.com\/pl\/\">Shenheng Power<\/a> i potwierd\u017a ostateczne limity z in\u017cynierem ds. narz\u0119dzi lub konsultantem.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-key-specification-inputs\">Cz\u0119\u015b\u0107 2. Kluczowe dane wej\u015bciowe specyfikacji<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Zablokuj te dane wej\u015bciowe przed normalizacj\u0105 ofert:<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Wej\u015bcie<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Dlaczego to wa\u017cne<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Typowe \u017ar\u00f3d\u0142o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Napi\u0119cie znamionowe i poziom izolacji<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Klasa wyposa\u017cenia i prze\u015bwit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Schemat jednokreskowy<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pr\u0105d znamionowy \/ kVA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Podstawa projektowania cieplnego<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Badanie obci\u0105\u017ceniowe<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Switching and protection scope<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Padmount-only vs packaged MV\/LV bay<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection study<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grupa wektorowa i zaczepy<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Uziemienie i regulacja napi\u0119cia<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wymagania dotycz\u0105ce medi\u00f3w<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Otoczenie i wysoko\u015b\u0107 n.p.m.<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Zmniejszenie obci\u0105\u017cenia i ch\u0142odzenie<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Karta danych obiektu<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil pad \/ cable basement interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Foundation and duct bank design<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil drawings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Technical review of padmount transformer and compact substation parameters\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/5.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Prosimy o wczesne przekazanie raport\u00f3w z test\u00f3w fabrycznych i rysunk\u00f3w pogl\u0105dowych, aby zespo\u0142y budowlane, ochrony i uruchomieniowe mog\u0142y pracowa\u0107 r\u00f3wnolegle.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-application-and-operating-boundaries\">Cz\u0119\u015b\u0107 3. Zastosowanie i granice eksploatacji<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A padmount transformer is commonly specified when the primary need is outdoor conversion on a concrete pad, with MV switching and LV boards supplied separately. It often fits residential feeders, light commercial sites, and utility laterals where the switching scheme is already defined elsewhere on the network.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A compact outdoor substation is typically preferred when the project needs a factory-integrated combination of MV switchgear, transformer, and LV distribution with a defined enclosure interface. That package can help industrial parks, renewable collection points, and schedule-driven EPC jobs that want fewer field interfaces.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Compare operating boundaries on at least four axes: switching scope, civil footprint, maintenance access, and cable entry direction. Harmonic-rich loads, corrosive atmospheres, or high altitude still require derating studies for either option.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For broader package-versus-built-on-site context, see <a href=\"https:\/\/shenhengglobal.com\/pl\/blog\/power-substation-vs-prefabricated-substation-key-differences-benefits-and-applications\/\">Power Substation vs Prefabricated Substation<\/a>. For transformer-only oil-immersed selection notes, review <a href=\"https:\/\/shenhengglobal.com\/pl\/blog\/how-to-choose-the-right-oil-immersed-transformer-a-buyers-guide\/\">How to Choose the Right Oil-Immersed Transformer<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-documentation-and-rfq-checklist\">Cz\u0119\u015b\u0107 4. Dokumentacja i lista kontrolna zapytania ofertowego<\/h2>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Dokument \/ przedmiot<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Cel<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Kiedy z\u0142o\u017cy\u0107 wniosek<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protok\u00f3\u0142 testu typu lub rutynowego<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sprawd\u017a oceny i straty<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Przed zam\u00f3wieniem<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rysunek GA i obci\u0105\u017cenie fundament\u00f3w<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Projektowanie budowlane i d\u017awigowe<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Faza projektowa<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Schemat po\u0142\u0105cze\u0144 \/ schemat jednokreskowy<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rozwi\u0105zanie i ochrona<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Przed wysy\u0142k\u0105<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Instrukcja obs\u0142ugi i konserwacji<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Szkolenie na miejscu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Przekazanie<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Lista cz\u0119\u015bci zamiennych<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tuleje, uszczelki, czujniki<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Negocjacje kontraktowe<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Lista kontrolna uruchomienia<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Stosunek, polaryzacja, testy izolacji<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Przed za\u0142\u0105czeniem<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Attach this table to RFQs so vendors return comparable technical packages for both padmount transformer and compact substation options.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-installation-testing-or-maintenance-notes\">Cz\u0119\u015b\u0107 5. Uwagi dotycz\u0105ce instalacji, testowania lub konserwacji<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Installation quality often determines long-term reliability more than small differences in quoted first cost. Confirm grounding, cable bending radius, torque values, and nameplate data against the approved design for whichever package you select.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Before energization, plan ratio tests, insulation resistance checks, functional protection tests, and\u2014where applicable\u2014oil sampling or thermal monitoring baselines. Compact packages also need enclosure door interlocks and LV feeder labeling checked against the approved drawing revision.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Maintenance access should be designed into the layout: oil sampling ports for liquid-filled padmount units, and clearances for MV and LV compartments inside compact outdoor enclosures.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-product-recommendation-and-fit-boundary\">Cz\u0119\u015b\u0107 6. Rekomendacja produktu i Granica dopasowania<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">When the comparison points to a factory-assembled outdoor bay rather than a stand-alone padmount transformer, Shenheng Power publishes a relevant catalog starting point at <a href=\"https:\/\/shenhengglobal.com\/pl\/product\/11kv-33kv-yb-series-compact-outdoor-electrical-substation\/\">Kompaktowa podstacja elektroenergetyczna napowietrzna 11kV\/33kV<\/a>.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Kompaktowa zewn\u0119trzna stacja transformatorowa 11kV\/33kV do przegl\u0105du in\u017cynierskiego\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/6.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Dopasuj obramowanie.<\/strong> This recommendation supports typical distribution and industrial scopes documented on the product page when MV switchgear, transformer, and LV distribution belong in one outdoor package. It is <strong>nie<\/strong> a substitute for a stand-alone padmount transformer when the approved single-line diagram only requires conversion hardware, and it is <strong>nie<\/strong> zamiennik dla studi\u00f3w specyficznych dla projektu, gdy maj\u0105 zastosowanie nietypowe poziomy przerw, skrajne wysoko\u015bci lub krajowe przepisy dotycz\u0105ce sieci energetycznych.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Je\u015bli Twoje badanie wskazuje na inn\u0105 kombinacj\u0119 kVA, napi\u0119cia lub schemat rozdzielnic, przejrzyj szerszy <a href=\"https:\/\/shenhengglobal.com\/pl\/prefabricated-substation\/\">kategoria stacji transformatorowych prefabrykowanych<\/a> i przes\u0142a\u0107 materia\u0142y do bada\u0144 przez <a href=\"https:\/\/shenhengglobal.com\/pl\/contact-us\/\">Skontaktuj si\u0119 z Shenheng Power<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-7-common-buyer-mistakes\">Cz\u0119\u015b\u0107 7. Typowe b\u0142\u0119dy kupuj\u0105cych<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Comparing a padmount transformer quotation with a compact substation quotation without aligning switching and LV scope.<\/li>\n<li style=\"margin:0 0 8px\">Pomini\u0119cie wymog\u00f3w dotycz\u0105cych wysoko\u015bci, otoczenia lub obudowy z zapytania ofertowego.<\/li>\n<li style=\"margin:0 0 8px\">Selecting equipment solely on first cost while ignoring civil pad, cable basement, and spare lead times.<\/li>\n<li style=\"margin:0 0 8px\">Uruchomienie przed uzgodnieniem ustawie\u0144 zabezpiecze\u0144 i danych znamionowych z zatwierdzonym projektem.<\/li>\n<li style=\"margin:0 0 8px\">Kopiowanie og\u00f3lnych deklaracji marketingowych do wniosk\u00f3w o pozwolenie bez dokumentacji rysunkowej.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faq\">Najcz\u0119\u015bciej zadawane pytania<\/h2>\n<h3 style=\"margin:28px 0 12px\">What is the difference between a padmount transformer and a compact substation?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A padmount transformer is typically a sealed outdoor distribution unit on a concrete pad. A compact substation usually packages MV switchgear, transformer, and LV distribution in one outdoor enclosure.<\/p>\n<h3 style=\"margin:28px 0 12px\">When should buyers choose a padmount transformer alone?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Choose a stand-alone padmount transformer when the site mainly needs MV-LV conversion and switching or LV boards are already specified as separate equipment.<\/p>\n<h3 style=\"margin:28px 0 12px\">What switching and LV functions does a compact substation typically include?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Many compact outdoor packages integrate incoming\/feeder MV switching with LV distribution around the transformer. Confirm the exact single-line diagram before comparing bids.<\/p>\n<h3 style=\"margin:28px 0 12px\">What civil and cable interfaces differ between the two packages?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Padmount units emphasize pad size, clearances, and primary\/secondary cable loops. Compact substations add enclosure footprint, basement or trench interfaces, and multi-compartment cable entry planning.<\/p>\n<h3 style=\"margin:28px 0 12px\">What documents should accompany factory shipment for either option?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Poprosz\u0119 o raporty z test\u00f3w, rysunki GA, schematy elektryczne, instrukcje obs\u0142ugi i listy cz\u0119\u015bci zamiennych zgodne z rewizj\u0105 zam\u00f3wienia.<\/p>\n<h3 style=\"margin:28px 0 12px\">Kiedy in\u017cynierowie powinni skonsultowa\u0107 si\u0119 z zespo\u0142em ds. przy\u0142\u0105czenia medi\u00f3w?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Przed zablokowaniem, nale\u017cy zapozna\u0107 si\u0119 z zakresem regulacji, filozofi\u0105 ochrony oraz wymogami dotycz\u0105cymi pomiar\u00f3w, kt\u00f3re pojawiaj\u0105 si\u0119 w umowie przy\u0142\u0105czeniowej lub na li\u015bcie kontrolnej sieci elektroenergetycznej.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">Bibliografia<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/5998\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1 transformatory mocy \u2014 wymagania og\u00f3lne<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/6143\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439-1 niskonapi\u0119ciowe zespo\u0142y rozdzielcze<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE standards portal for distribution transformer requirements<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Buyers comparing a padmount transformer with a compact outdoor substation need a practical way to separate equipment scope, civil interface, and documentation before quotations look interchangeable. This guide summarizes decision steps used by EPC teams and facility engineers when they decide whether a stand-alone padmount transformer is enough, or whether a factory-assembled compact substation better [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1421,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1698","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/posts\/1698","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/comments?post=1698"}],"version-history":[{"count":1,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/posts\/1698\/revisions"}],"predecessor-version":[{"id":1715,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/posts\/1698\/revisions\/1715"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/media\/1421"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/media?parent=1698"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/categories?post=1698"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/pl\/wp-json\/wp\/v2\/tags?post=1698"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}