{"id":3634,"date":"2026-11-09T08:58:11","date_gmt":"2026-11-09T00:58:11","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3634"},"modified":"2026-11-11T09:48:15","modified_gmt":"2026-11-11T01:48:15","slug":"sbh25-m-10kv-three-phase-oil-immersed-amorphous-alloy-three-dimensional-wound-core-distribution-transformer","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/nl\/product\/sbh25-m-10kv-three-phase-oil-immersed-amorphous-alloy-three-dimensional-wound-core-distribution-transformer\/","title":{"rendered":"SBH25-M 10kV Drie-fasige olie-gevulde amorfe legering driedimensionale gewikkelde kern verdeeltransformator"},"content":{"rendered":"<h2>Productoverzicht en toepassingen<\/h2>\n<p>De SBH25-M is een nieuwe generatie energiezuinige verdeeltransformatoren die meerdere voordelen combineert. De kern gebruikt hoogwaardig amorf legering materiaal en een unieke driedimensionale gewonden kernstructuur, wat resulteert in uitstekende magnetische prestaties en ultra-laag geen-belastingverlies. Dit vermindert aanzienlijk de operationele kosten over de volledige levenscyclus van de apparatuur, waardoor het een zeer kosteneffectieve keuze is voor langdurige werking. De transformator heeft een volledig afgesloten structuur met een beschermingsgraad van IP32 of hoger, geschikt voor pole-mount buiteninstallatie en distributietransformatorgebied. De hoogspanningszijde is uitgerust met een 10kV spanningsniveau en een \u201cDyn11 of Yyn0\u201d vectorgroep, die harmonischen effectief onderdrukt en de stabiliteit van de stroomkwaliteit verbetert. Het wordt veel toegepast in standaard distributiescenario\u2019s zoals stedelijke en landelijke netrenovatie, fotovolta\u00efsche netaansluiting en commerci\u00eble gebouwen.<\/p>\n<h2>Belangrijkste kenmerken en constructieontwerp<\/h2>\n<p>1. Amorfe Legering Kern: Het gebruik van amorfe legering als kernmateriaal vermindert het geen-belastingverlies drastisch (met 60%-80% vergeleken met traditionele siliciumstaal), wat leidt tot aanzienlijke energiebesparing en vermindering van koolstofuitstoot.<\/p>\n<p>2. Driedimensionale Gewonden Kernstructuur (RL): Het driedimensionale driehoekige gewonden kernontwerp zorgt voor een meer uniforme magnetische fluxverdeling, lagere geluidsniveaus en hogere weerstand tegen kortsluitkrachten in vergelijking met traditionele gestapelde kernen.<\/p>\n<p>3. Gesealde Constructie (M): De transformator heeft een gesealde constructie met een beschermingsgraad van IP32 of hoger, wat uitstekende bescherming biedt tegen ruwe omgevingsomstandigheden en veilige buitenwerking mogelijk maakt.<\/p>\n<p>4. Laag Verlies en Hoge Effici\u00ebntie: De transformator realiseert een significante vermindering van zowel geen-belasting- als belastingverliezen, en voldoet aan de energie-effici\u00ebntiestandaard GB 20052. Beschikbaar in energie-effici\u00ebntieklassen 1 en 2 (NX1 en NX2).<\/p>\n<p>5. Sterke Kortsluitbestendigheid: Het unieke structurele ontwerp en hoogwaardige materialen zorgen voor uitstekende kortsluitbestendigheid, hoge betrouwbaarheid en stabiele werking onder verschillende belastingomstandigheden.<\/p>\n<p>6. Breed Capaciteitbereik en Flexibele Configuratie: Beschikbaar in nominale capaciteiten van 30kVA tot 2500kVA. Hoogspanningsaftakkingsbereiken omvatten \u00b12\u00d72.5% en \u00b15%, met een vectorgroep van Dyn11 of Yyn0. De laagspanningszijde is 0,4kV, en de impedantie-spanning varieert van 4% tot 4.5% of 5% afhankelijk van capaciteit, wat flexibiliteit voor verschillende netvereisten garandeert.<\/p>\n<h2>Productparameters<\/h2>\n<table width=\"792\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"72\">Capacity<br \/>\n(kVar)<\/td>\n<td colspan=\"3\" width=\"216\">Spanningcombinatie en aftapping<br \/>\nbereik(kV)<\/td>\n<td rowspan=\"2\" width=\"72\">Vectorgroep<\/td>\n<td colspan=\"2\" width=\"144\">SBH25-M<\/td>\n<td colspan=\"2\" width=\"144\">SBH21-M<\/td>\n<td rowspan=\"2\" width=\"72\">Geen belasting<br \/>\nstroom<\/td>\n<td rowspan=\"2\" width=\"72\">Impedantie<\/td>\n<\/tr>\n<tr>\n<td>Invoer<br \/>\n(kV)<\/td>\n<td>HV-aansluiting<br \/>\nbereik%<\/td>\n<td>uitgang<br \/>\n(kV)<\/td>\n<td>Geen belastingverlies<\/td>\n<td>Vermogensverlies bij vol belasting<\/td>\n<td>Geen belasting<br \/>\nverlies<\/td>\n<td>Vermogensverlies bij vol belasting<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td rowspan=\"19\">\u00a06<br \/>\n6.3<br \/>\n6.6<br \/>\n10<br \/>\n10.5<br \/>\n11<\/td>\n<td rowspan=\"19\">\u00b12\u00d72.5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\">0.4<\/td>\n<td rowspan=\"10\">Dyn11<br \/>\nYyn0<br \/>\nYzn11<\/td>\n<td>25<\/td>\n<td>510\/480<\/td>\n<td>33<\/td>\n<td>535\/510<\/td>\n<td>1.5<\/td>\n<td rowspan=\"12\">4<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>35<\/td>\n<td>735\/700<\/td>\n<td>43<\/td>\n<td>780\/745<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>40<\/td>\n<td>880\/840<\/td>\n<td>50<\/td>\n<td>930\/890<\/td>\n<td>1.1<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>50<\/td>\n<td>1060\/1010<\/td>\n<td>60<\/td>\n<td>1120\/1070<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>60<\/td>\n<td>1270\/1215<\/td>\n<td>75<\/td>\n<td>1350\/1285<\/td>\n<td>0.9<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>70<\/td>\n<td>1530\/1450<\/td>\n<td>85<\/td>\n<td>1615\/1540<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>80<\/td>\n<td>1870\/1780<\/td>\n<td>100<\/td>\n<td>1975\/1880<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>95<\/td>\n<td>2210\/2100<\/td>\n<td>120<\/td>\n<td>2330\/2225<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>110<\/td>\n<td>2590\/2470<\/td>\n<td>140<\/td>\n<td>2735\/2610<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>135<\/td>\n<td>3100\/2950<\/td>\n<td>170<\/td>\n<td>3275\/3120<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td rowspan=\"9\">Dyn11<br \/>\nYyn\u2070<\/td>\n<td>160<\/td>\n<td>3660\/3480<\/td>\n<td>200<\/td>\n<td>3865\/3675<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>190<\/td>\n<td>4380\/4170<\/td>\n<td>240<\/td>\n<td>4625\/4400<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>250<\/td>\n<td>5020<\/td>\n<td>320<\/td>\n<td>5300<\/td>\n<td>0.3<\/td>\n<td rowspan=\"5\">4.5<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>300<\/td>\n<td>6075<\/td>\n<td>380<\/td>\n<td>6415<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>360<\/td>\n<td>8340<\/td>\n<td>450<\/td>\n<td>8800<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>425<\/td>\n<td>9720<\/td>\n<td>530<\/td>\n<td>10260<\/td>\n<td>0.2<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>500<\/td>\n<td>11745<\/td>\n<td>630<\/td>\n<td>12400<\/td>\n<td>0.2<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>550<\/td>\n<td>14000<\/td>\n<td>710<\/td>\n<td>14800<\/td>\n<td>0.2<\/td>\n<td rowspan=\"2\">5<\/td>\n<\/tr>\n<tr>\n<td>2500<\/td>\n<td>670<\/td>\n<td>15450<\/td>\n<td>860<\/td>\n<td>16300<\/td>\n<td>0.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Toepassingsdetails<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3850\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3851\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3852\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3853\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>De SBH25-M serie is een lijn van 10kV driefasige olie-ondergedompelde amorf legering kern verdeeltransformatoren. Met een driedimensionale gewonden kernstructuur (RL) en gebruikmakend van amorf legering als magnetisch materiaal, bereiken deze transformatoren geen-belastingverliezen die ongeveer 60% tot 80% lager zijn dan die van traditionele siliciumstaaltransformatoren. Ze zijn essenti\u00eble apparatuur voor energiebesparende renovatie van het elektriciteitsnet. De serie voldoet aan GB\/T 25446 en GB 20052 normen en is ontworpen voor pole-mount buiteninstallatie of distributietransformatorgebied. Beschikbaar in 21kVA en 25kVA nominale capaciteiten, geschikt voor een breed scala aan toepassingen zoals stedelijke en landelijke netrenovatie, fotovolta\u00efsche netaansluiting en commerci\u00eble gebouwen.<\/p>","protected":false},"featured_media":3635,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3634","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product\/3634","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/comments?post=3634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/media\/3635"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/media?parent=3634"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_brand?post=3634"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_cat?post=3634"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_tag?post=3634"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}