{"id":3610,"date":"2026-11-09T08:50:41","date_gmt":"2026-11-09T00:50:41","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3610"},"modified":"2026-11-11T09:19:50","modified_gmt":"2026-11-11T01:19:50","slug":"s13-10kv-and-20kv-oil-immersed-power-distribution-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/nl\/product\/s13-10kv-and-20kv-oil-immersed-power-distribution-transformers\/","title":{"rendered":"S13 10kV en 20kV Olie-gedrenkte Vermogensdistributietransformatoren"},"content":{"rendered":"<h2>Productoverzicht en toepassingen<\/h2>\n<p>De S13-serie zijn volledig afgesloten olie-gedrenkte vermogensdistributietransformatoren ontworpen voor AC-systemen met een nominale frequentie van 50Hz en een maximale bedrijfsspanning van 20kV. Ze worden voornamelijk gebruikt als distributietransformatoren in diverse industri\u00eble ondernemingen, waaronder olie, metallurgie, chemische engineering, textiel en lichte industrie, evenals op locaties met hoge stofniveaus. De transformatoren zijn ontworpen voor hoge effici\u00ebntie, laag verlies en betrouwbare werking, waardoor ze geschikt zijn voor zowel binnen- als buiteninstallaties (buiteninstallatie vereist dat direct zonlicht, corrosieve gassen of stof worden vermeden, terwijl binneninstallatie voldoende warmteafvoer en veiligheidsafstand vereist).<\/p>\n<h2>Belangrijkste kenmerken en constructieontwerp<\/h2>\n<p>1. Kern: De kern is gemaakt van hoogpermeabele korrelgeori\u00ebnteerde koudgewalste siliciumstaalplaat. Het gebruikt een nieuwe structuur met volledig verstek gestapelde kern. De kernarm heeft een meervoudige trede ronde doorsnede, en de yoke heeft een gelijke doorsnede als de kernarm, wat zorgt voor hoge magnetische effici\u00ebntie en lage geen-belasting verlies.<\/p>\n<p>2. Wikkeling: De wikkelingen zijn ontworpen met geprofileerde olieleidingen, gebruikmakend van een niet-verniste impregneringsproces en vastgezet met bindbanden. Alle wikkelingen zijn concentrische spoelen. De hoogspanningswikkeling is uitgerust met taps die overeenkomen met de vereiste tapspanningen, die verbonden zijn met de tapwisselaar. De tapwisselaar is gemonteerd op de tankdeksel, en de tapspanningsaanpassing kan alleen worden uitgevoerd na uitschakeling.<\/p>\n<p>3. Veiligheidsbeschermingsapparaten: Transformatoren met een capaciteit van 30-2000 kVA zijn voorzien van een drukontlastklep. Een gasrelais met alarm- en uitschakelterminals kan volgens gebruikersvereisten worden ge\u00efnstalleerd.<\/p>\n<p>4. Olietemperatuurmeetapparaat: Alle transformatoren zijn uitgerust met een socket voor een glazen thermometer, die op de bovenkant van de oliebak is ge\u00efnstalleerd en tot 120\u00b110 mm in de olie steekt. Transformatoren met een capaciteit van 1000-2000 kVA zijn voorzien van een buitenthermometer voor signaalgebruik.<\/p>\n<p>5. Transformatorvat: Het transformatorvat is opgebouwd met geprofileerde wanden, en het oppervlak is behandeld met poedercoating voor een stevige verfhechting. De geprofileerde wanden dienen voor warmteafvoer en het \u201cademen\u201d van volumeverschillen in de transformatorolie veroorzaakt door temperatuurschommelingen. Hierdoor elimineert de volledig afgesloten transformator de noodzaak voor een oliebuffer, waardoor de totale hoogte van de eenheid wordt verminderd. Tijdens de encapsulatie wordt vacu\u00fcmolie gevuld om vocht binnenin de transformator volledig te verwijderen. De transformatorolie wordt ge\u00efsoleerd van contact met lucht, waardoor zuurstof en vochtinbraak die de isolatiewaarde zouden verminderen en de olieversnelling zouden veroorzaken, effectief worden voorkomen. Daarom is regelmatige oliebemonstering niet vereist.<\/p>\n<p>6. Bedrijfsomstandigheden: Geschikt voor gebieden met een hoogte tot 1.000 meter, een maximale omgevingstemperatuur van +40\u00b0C en een minimale omgevingstemperatuur van -25\u00b0C of -5\u00b0C. De nominale frequentie van het aangesloten elektriciteitsnet is 50Hz, en de fluctuatie van de voedingsspanning mag niet meer dan \u00b15% van de nominale spanning bedragen. De vervormingsgraad van de golfvorm moet voldoen aan de harmonische beheersingsvereisten van het elektriciteitssysteem. De transformatoren kunnen buiten of binnen in goed geventileerde ruimtes worden ge\u00efnstalleerd. Voor buiteninstallatie moet direct zonlicht, corrosieve gassen of stofophoping worden vermeden; voor binneninstallatie moet voldoende warmteafvoer en veiligheidsafstand worden gegarandeerd. De transformator mag langdurig onder nominale capaciteit blijven werken en heeft een bepaalde kortdurende overbelastingscapaciteit. Bij gebruik in speciale omgevingen zoals onweersgevoelige gebieden, hoge luchtvochtigheid, zware vervuiling, chemische corrosie of seismische zones, dient vooraf te worden gewaarschuwd en moet een versterkt beschermingsschema worden toegepast.<\/p>\n<h2>Productparameters<\/h2>\n<table style=\"border-collapse: collapse; width: 50.2877%; height: 604px;\" border=\"0\" width=\"648\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 54.00pt; width: 54.00pt;\" rowspan=\"4\" width=\"72\" height=\"72\">cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<br \/>\nCapacity<br \/>\n(kVA)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Hoog<br \/>\nspanning<br \/>\n(KV)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Hoge spanning<br \/>\naftapbereik<br \/>\n(%)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Low<br \/>\nspanning<br \/>\n(kV)<\/td>\n<td class=\"et2\" style=\"width: 162.00pt;\" colspan=\"3\" width=\"216\">S13-M<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Geen belasting<br \/>\nstroom<br \/>\n(%)<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Short-circuit<br \/>\nimpedantie%<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" colspan=\"3\">elektrisch strookstaal<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td rowspan=\"2\">Geen belastingverlies kW<\/td>\n<td colspan=\"2\">Volbelastingverlies kW<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td>Dyn11\/Yzn11<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">30<\/td>\n<td rowspan=\"19\">63<br \/>\n10<br \/>\n10.5<\/td>\n<td rowspan=\"19\">\u00b12\u00d72.5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\" align=\"right\">0.4<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">630<\/td>\n<td align=\"right\">710<\/td>\n<td align=\"right\">1.2<\/td>\n<td rowspan=\"12\" align=\"right\">4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">50<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">910<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">1.04<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">63<\/td>\n<td align=\"right\">110<\/td>\n<td align=\"right\">1090<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">80<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">1310<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">100<\/td>\n<td align=\"right\">150<\/td>\n<td align=\"right\">1580<\/td>\n<td align=\"right\">1570<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">125<\/td>\n<td align=\"right\">170<\/td>\n<td align=\"right\">1890<\/td>\n<td align=\"right\">1850<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">160<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2310<\/td>\n<td align=\"right\">2130<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">200<\/td>\n<td align=\"right\">240<\/td>\n<td align=\"right\">2730<\/td>\n<td align=\"right\">2530<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">250<\/td>\n<td align=\"right\">290<\/td>\n<td align=\"right\">3200<\/td>\n<td align=\"right\">2760<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">315<\/td>\n<td align=\"right\">340<\/td>\n<td align=\"right\">3830<\/td>\n<td align=\"right\">3470<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">400<\/td>\n<td align=\"right\">410<\/td>\n<td align=\"right\">4520<\/td>\n<td align=\"right\">3990<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">500<\/td>\n<td align=\"right\">480<\/td>\n<td align=\"right\">5410<\/td>\n<td align=\"right\">4880<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">630<\/td>\n<td align=\"right\">570<\/td>\n<td colspan=\"2\" align=\"right\">6200<\/td>\n<td align=\"right\">0.48<\/td>\n<td rowspan=\"5\" align=\"right\">4.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">800<\/td>\n<td align=\"right\">700<\/td>\n<td colspan=\"2\" align=\"right\">7500<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1000<\/td>\n<td align=\"right\">830<\/td>\n<td colspan=\"2\" align=\"right\">10300<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1250<\/td>\n<td align=\"right\">970<\/td>\n<td colspan=\"2\" align=\"right\">12000<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1600<\/td>\n<td align=\"right\">1170<\/td>\n<td colspan=\"2\" align=\"right\">14500<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2000<\/td>\n<td align=\"right\">1360<\/td>\n<td colspan=\"2\" align=\"right\">18300<\/td>\n<td align=\"right\">0.32<\/td>\n<td rowspan=\"2\" align=\"right\">5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2500<\/td>\n<td align=\"right\">1600<\/td>\n<td colspan=\"2\" align=\"right\">21200<\/td>\n<td align=\"right\">0.32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Toepassingsdetails<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3861\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3862\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3863\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3864\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>De S13-serie zijn volledig afgesloten olie-gedrenkte transformatoren geschikt voor elektriciteitssystemen met een wisselstroomfrequentie van 50Hz en een nominaal bedrijfsspanning van 20kV of minder. Ze worden gebruikt als distributietransformatoren in ondernemingen zoals olie, metallurgie, chemische engineering, textiel en lichte industrie, evenals op plaatsen met grote hoeveelheden stof. De transformatoren beschikken over een hoogbetrouwbare kern gemaakt van hoogpermeabele korrelgeori\u00ebnteerde koudgewalste siliciumstaalplaat, een geavanceerd isolatiesysteem en een volledig afgesloten oliebakontwerp, wat onderhoudsvrij gebruik en een lange levensduur garandeert.<\/p>","protected":false},"featured_media":3611,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3610","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/comments?post=3610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/media\/3611"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_brand?post=3610"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_cat?post=3610"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/nl\/wp-json\/wp\/v2\/product_tag?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}