{"id":3610,"date":"2026-11-09T08:50:41","date_gmt":"2026-11-09T00:50:41","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3610"},"modified":"2026-11-11T09:19:50","modified_gmt":"2026-11-11T01:19:50","slug":"s13-10kv-and-20kv-oil-immersed-power-distribution-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/ms\/product\/s13-10kv-and-20kv-oil-immersed-power-distribution-transformers\/","title":{"rendered":"Transformator Pengagihan Kuasa Berendam Minyak S13 10kV dan 20kV"},"content":{"rendered":"<h2>Gambaran Keseluruhan Produk &amp; Aplikasi<\/h2>\n<p>Siri S13 adalah transformator pengagihan kuasa berendam minyak yang sepenuhnya tertutup yang direka untuk sistem AC dengan frekuensi ber rated 50Hz dan voltan kerja maksimum 20kV. Ia digunakan terutamanya sebagai transformator pengagihan dalam pelbagai perusahaan industri, termasuk petroleum, metalurgi, kejuruteraan kimia, tekstil, dan industri ringan, serta di lokasi dengan tahap debu yang tinggi. Transformator ini direka untuk kecekapan tinggi, kerugian rendah, dan operasi yang boleh dipercayai, menjadikannya sesuai untuk pemasangan dalam dan luar bangunan (pemasangan luar bangunan memerlukan perlindungan dari cahaya matahari langsung, gas korosif, atau debu, manakala pemasangan dalam bangunan memerlukan ruang penyejukan haba yang mencukupi dan jarak keselamatan).<\/p>\n<h2>Ciri-ciri Utama &amp; Reka Bentuk Struktur<\/h2>\n<p>1. Teras: Teras diperbuat daripada lembaran keluli silikon berorientasi bijirin yang di-rolled sejuk dengan daya tahan tinggi. Ia mengguna struktur jenis baru dengan teras berlapis miter sepenuhnya. Bahagian lengan teras mempunyai bahagian melintang bulat berperingkat berbilang langkah, dan yoke mempunyai bahagian melintang yang sama dengan lengan teras, memastikan kecekapan magnetik tinggi dan kerugian tanpa beban yang rendah.<\/p>\n<p>2. Lilitan: Lilitan direka dengan saluran minyak beralun, menggunakan proses impregnasi tanpa varnis dan dipasang dengan pita pengikat. Semua lilitan adalah gegelung koncentri. Lilitan voltan tinggi dilengkapi dengan tap yang bersesuaian dengan voltan tap yang diperlukan, yang disambungkan ke penukar tap. Penukar tap dipasang pada penutup tangki, dan pelarasan voltan tap hanya boleh dilakukan selepas kuasa dimatikan.<\/p>\n<p>3. Peranti Perlindungan Keselamatan: Transformator dengan kapasiti 30-2000 kVA dilengkapi injap pelepasan tekanan. Relay gas dengan terminal amaran dan trip boleh dipasang mengikut keperluan pengguna.<\/p>\n<p>4. Peranti Pengukur Suhu Minyak: Semua transformator dilengkapi dengan soket untuk termometer kaca, yang dipasang di bahagian atas tangki minyak dan melanjut ke dalam minyak pada kedalaman 120\u00b110 mm. Transformator dengan kapasiti 1000-2000 kVA dilengkapi dengan termometer isyarat luar.<\/p>\n<p>5. Tangki Transformator: Tangki transformator dibina dengan dinding beralun, dan permukaannya dirawat dengan lapisan serbuk untuk lekatan cat yang kukuh. Dinding beralun berfungsi sebagai penyejukan haba dan untuk mengimbangi perubahan volume minyak transformator yang disebabkan oleh fluktuasi suhu. Oleh itu, transformator yang sepenuhnya tertutup menghapuskan keperluan untuk konservator minyak, mengurangkan ketinggian keseluruhan unit. Pengisian minyak vakum digunakan semasa penutupan transformator untuk menghilangkan kelembapan di dalamnya sepenuhnya. Minyak transformator diasingkan dari sentuhan udara, secara efektif menghalang masuk oksigen dan kelembapan yang akan merosakkan prestasi penebat dan mempercepat penuaan minyak. Oleh itu, ujian sampel minyak secara berkala tidak diperlukan.<\/p>\n<p>6. Keadaan Kerja: Sesuai untuk kawasan dengan ketinggian tidak melebihi 1,000 meter, suhu ambien maksimum +40\u00b0C, dan suhu ambien minimum -25\u00b0C atau -5\u00b0C. Frekuensi ber rated rangkaian kuasa yang disambungkan ialah 50Hz, dan julat fluktuasi voltan bekalan kuasa tidak melebihi \u00b15% daripada voltan ber rated. Kadar distorsi gelombang hendaklah memenuhi keperluan pengurusan harmonik sistem kuasa. Transformator boleh dipasang di luar atau dalam bangunan di tempat yang berpengudaraan baik. Untuk pemasangan luar, cahaya matahari langsung, gas korosif, atau pengumpulan debu harus dielakkan; untuk pemasangan dalam bangunan, ruang penyejukan haba yang mencukupi dan jarak keselamatan harus dipastikan. Transformator dibenarkan beroperasi secara berterusan dalam jangka masa panjang pada kapasiti ber rated dan mempunyai kapasiti beban lebih masa yang tertentu. Jika digunakan di persekitaran khas seperti kawasan berpetir, kelembapan tinggi, pencemaran berat, korosi kimia, atau zon seismik, notifikasi awal harus diberikan, dan skim perlindungan yang dipertingkatkan harus disediakan.<\/p>\n<h2>Parameter Produk<\/h2>\n<table style=\"border-collapse: collapse; width: 50.2877%; height: 604px;\" border=\"0\" width=\"648\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 54.00pt; width: 54.00pt;\" rowspan=\"4\" width=\"72\" height=\"72\">cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<br \/>\nCapacity<br \/>\n(kVA)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Tinggi<br \/>\nvoltan<br \/>\n(KV)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Tegangan tinggi<br \/>\nkawalan tapping<br \/>\n(%)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Low<br \/>\nvoltan<br \/>\n(kV)<\/td>\n<td class=\"et2\" style=\"width: 162.00pt;\" colspan=\"3\" width=\"216\">S13-M<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Beban kosong<br \/>\narus<br \/>\n(%)<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Short-circuit<br \/>\nimpedans%<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" colspan=\"3\">keluli jalur elektrik<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td rowspan=\"2\">Kerosakan beban kosong kW<\/td>\n<td colspan=\"2\">Kerosakan beban penuh kW<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td>Dyn11\/Yzn11<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">30<\/td>\n<td rowspan=\"19\">63<br \/>\n10<br \/>\n10.5<\/td>\n<td rowspan=\"19\">\u00b12\u00d72.5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\" align=\"right\">0.4<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">630<\/td>\n<td align=\"right\">710<\/td>\n<td align=\"right\">1.2<\/td>\n<td rowspan=\"12\" align=\"right\">4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">50<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">910<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">1.04<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">63<\/td>\n<td align=\"right\">110<\/td>\n<td align=\"right\">1090<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">80<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">1310<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">100<\/td>\n<td align=\"right\">150<\/td>\n<td align=\"right\">1580<\/td>\n<td align=\"right\">1570<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">125<\/td>\n<td align=\"right\">170<\/td>\n<td align=\"right\">1890<\/td>\n<td align=\"right\">1850<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">160<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2310<\/td>\n<td align=\"right\">2130<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">200<\/td>\n<td align=\"right\">240<\/td>\n<td align=\"right\">2730<\/td>\n<td align=\"right\">2530<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">250<\/td>\n<td align=\"right\">290<\/td>\n<td align=\"right\">3200<\/td>\n<td align=\"right\">2760<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">315<\/td>\n<td align=\"right\">340<\/td>\n<td align=\"right\">3830<\/td>\n<td align=\"right\">3470<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">400<\/td>\n<td align=\"right\">410<\/td>\n<td align=\"right\">4520<\/td>\n<td align=\"right\">3990<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">500<\/td>\n<td align=\"right\">480<\/td>\n<td align=\"right\">5410<\/td>\n<td align=\"right\">4880<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">630<\/td>\n<td align=\"right\">570<\/td>\n<td colspan=\"2\" align=\"right\">6200<\/td>\n<td align=\"right\">0.48<\/td>\n<td rowspan=\"5\" align=\"right\">4.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">800<\/td>\n<td align=\"right\">700<\/td>\n<td colspan=\"2\" align=\"right\">7500<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1000<\/td>\n<td align=\"right\">830<\/td>\n<td colspan=\"2\" align=\"right\">10300<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1250<\/td>\n<td align=\"right\">970<\/td>\n<td colspan=\"2\" align=\"right\">12000<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1600<\/td>\n<td align=\"right\">1170<\/td>\n<td colspan=\"2\" align=\"right\">14500<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2000<\/td>\n<td align=\"right\">1360<\/td>\n<td colspan=\"2\" align=\"right\">18300<\/td>\n<td align=\"right\">0.32<\/td>\n<td rowspan=\"2\" align=\"right\">5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2500<\/td>\n<td align=\"right\">1600<\/td>\n<td colspan=\"2\" align=\"right\">21200<\/td>\n<td align=\"right\">0.32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Butiran Permohonan<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3861\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3862\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3863\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3864\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Siri S13 adalah transformator berendam minyak yang sepenuhnya tertutup sesuai untuk sistem kuasa dengan frekuensi AC 50Hz dan voltan kerja ber rated 20kV atau kurang. Ia digunakan sebagai transformator pengagihan dalam perusahaan seperti petroleum, metalurgi, kejuruteraan kimia, tekstil, dan industri ringan, serta di tempat yang mempunyai banyak debu. Transformator ini menampilkan teras yang sangat boleh dipercayai yang diperbuat daripada lembaran keluli silikon berorientasi bijirin yang di-rolled sejuk, sistem penebat yang canggih, dan reka bentuk tangki minyak yang sepenuhnya tertutup, memastikan operasi tanpa penyelenggaraan dan jangka hayat yang panjang.<\/p>","protected":false},"featured_media":3611,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3610","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/product\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/comments?post=3610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/media\/3611"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/product_brand?post=3610"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/product_cat?post=3610"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ms\/wp-json\/wp\/v2\/product_tag?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}