{"id":2018,"date":"2026-08-06T14:00:00","date_gmt":"2026-08-06T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/withdrawable-lv-switchgear-service-access\/"},"modified":"2026-08-06T14:00:00","modified_gmt":"2026-08-06T06:00:00","slug":"withdrawable-lv-switchgear-service-access","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/ja\/blog\/withdrawable-lv-switchgear-service-access\/","title":{"rendered":"Withdrawable LV Switchgear: Service Access Planning for Plants"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Plant teams specifying <strong>withdrawable switchgear<\/strong> for LV distribution must plan compartment access, interlocking, and spare-drawer logistics \u2014 not only busbar ratings \u2014 before locking GGD\/MNS-style board layouts.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This withdrawable switchgear guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>withdrawable-lv-switchgear-service-access<\/code> \u2014\u305d\u308c\u306f\u3001\u96fb\u529b\u4f1a\u793e\u3084\u30b3\u30f3\u30b5\u30eb\u30bf\u30f3\u30c8\u306e\u627f\u8a8d\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"withdrawable switchgear planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u76ee\u6b21<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Service-access-as-a-design-requirement-,-not-an-afterthought\">Part 1. Service access as a design requirement, not an afterthought<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Withdrawable-Switchgear-inputs-to-lock-early\">Part 2. Withdrawable Switchgear inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Interlocks-,-shutters-,-and-segregation-boundaries\">Part 3. Interlocks, shutters, and segregation boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Service-access-items-to-embed-in-the-LV-board-RFQ\">Part 4. Service-access items to embed in the LV board RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-FAT-and-site-drills-before-live-racking\">Part 5. FAT and site drills before live racking<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Withdrawable-Switchgear-catalog-starting-point\">Part 6. Withdrawable Switchgear catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Access-planning-mistakes-on-LV-boards\">Part 7. Access planning mistakes on LV boards<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Service-access-as-a-design-requirement-,-not-an-afterthought\">Part 1. Service access as a design requirement, not an afterthought<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Withdrawable designs speed feeder maintenance when aisles, lifting, and interlocks are designed in. Crowded rooms that only fit the cabinet footprint often block safe racking later.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Capture maintenance philosophy in the RFQ: expected racking frequency, spare drawer storage, and whether live-compartment work rules apply on site.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u95a2\u9023\u8aad\u66f8\uff1a <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/mns-withdrawable-switchgear-maintenance-access\/\">MNS withdrawable switchgear maintenance access<\/a> \u305d\u3057\u3066 <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/ggd-vs-mns-lv-switchgear-comparison\/\">GGD vs MNS LV switchgear comparison<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Withdrawable-Switchgear-inputs-to-lock-early\">Part 2. Withdrawable Switchgear inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Access input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Plant impact if missed<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u6240\u6709\u8005<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Form of separation \/ internal segregation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe maintenance zones<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spec \/ IEC form<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Withdrawable vs fixed feeders map<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong cubicle type ordered<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u5358\u4e00\u7dda<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aisle width and door swing<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Blocked racking<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Layout \/ civil<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and shutter requirements<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Racking incidents<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ops \/ manufacturer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc \/ short-circuit withstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Personnel risk<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u6545\u969c\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spare drawer \/ module list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Long outage on failure<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Maintenance planner<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and gland plates<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rear access conflicts<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"withdrawable switchgear specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u91cd\u8981\uff1a<\/strong> For withdrawable switchgear, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC\u898f\u683c\u306e\u5b9f\u8df5<\/a> \u305d\u3057\u3066\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u6a29\u9650\u306e\u30bd\u30fc\u30b9\u30ce\u30fc\u30c8\u3002.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Interlocks-,-shutters-,-and-segregation-boundaries\">Part 3. Interlocks, shutters, and segregation boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Document racking interlocks so drawers cannot be inserted or withdrawn under unsafe conditions. Shutters should cover live parts when a module is removed.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Internal segregation (form of separation) must match the maintenance rules used by the plant \u2014 higher forms reduce exposure but change cost and footprint.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Service-access-items-to-embed-in-the-LV-board-RFQ\">Part 4. Service-access items to embed in the LV board RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u76ee\u7684<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u5f15\u7528\u4ed8\u304d\u3067\u9001\u4fe1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Feeder withdrawable\/fixed matrix<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle type clarity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Form of separation requirement<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Maintenance safety<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 specification<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aisle \/ access GA constraints<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room fit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 layout annex<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock description<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe racking<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spare module list + lead times<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Outage planning<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 commercial<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">FAT racking demonstration plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Witness checklist<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 contract<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nameplate + setting sheets<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning file<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u30d9\u30f3\u30c0\u30fc\u304c\u30ab\u30bf\u30ed\u30b0\u306e\u629c\u7c8b\u3067\u306f\u306a\u304f\u6bd4\u8f03\u53ef\u80fd\u306a\u6280\u8853\u30d1\u30c3\u30b1\u30fc\u30b8\u3092\u63d0\u51fa\u3059\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30c6\u30fc\u30d6\u30eb\u3092\u3059\u3079\u3066\u306eRFQ\u6539\u8a02\u7248\u306b\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-FAT-and-site-drills-before-live-racking\">Part 5. FAT and site drills before live racking<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Witness mechanical racking, shutter operation, and interlock defeat attempts during FAT when the contract requires it. On site, train operators on the approved sequence before the first live racking event.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Store spare drawers in labeled locations with matching ratings \u2014 mismatched spares create false confidence during emergencies.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Withdrawable-Switchgear-catalog-starting-point\">Part 6. Withdrawable Switchgear catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many withdrawable switchgear scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/ja\/product\/industrial-lv-power-switchgear-ggd-ggj-mns-low-voltage-metal-enclosed-switchgear\/\">GGD \/ GGJ \/ MNS low voltage metal-enclosed switchgear<\/a> \u88fd\u54c1\u30da\u30fc\u30b8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30ab\u30bf\u30ed\u30b0\u30a8\u30f3\u30c8\u30ea\u30fc\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"GGD \/ GGJ \/ MNS low voltage metal-enclosed switchgear for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Industrial-LV-Power-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5236\u9650\uff1a<\/strong> \u306e\u305f\u3081\u306e <code>withdrawable switchgear<\/code> (<code>withdrawable-lv-switchgear-service-access<\/code>)\u3001\u30ea\u30f3\u30af\u3055\u308c\u305f\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u306f\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u306e\u51fa\u767a\u70b9\u3068\u3057\u3066\u306e\u307f\u6271\u3063\u3066\u304f\u3060\u3055\u3044\u3002 <strong>\u3067\u306f\u306a\u3044<\/strong> \u30d5\u30ea\u30fc\u30ba <code>withdrawable switchgear<\/code> \u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u6545\u969c\u30b9\u30bf\u30c7\u30a3\u3001\u9ad8\u5ea6\u30c7\u30a3\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u307e\u305f\u306f\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u306e\u578b\u5f0f\u627f\u8a8d\u306e\u5305\u7d61\u7dda\u304c\u3001\u8a72\u5f53\u3059\u308b\u88fd\u54c1\u30da\u30fc\u30b8\u306e\u516c\u958b\u5b9a\u683c\u3092\u8d85\u904e\u3059\u308b\u5834\u5408\u306e\u8abf\u9054\u3002.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the withdrawable switchgear study points to a different scheme or rating for withdrawable-lv-switchgear-service-access, browse the <a href=\"https:\/\/shenhengglobal.com\/ja\/low-voltage-switchgear\/\">\u30ab\u30c6\u30b4\u30ea\u30da\u30fc\u30b8<\/a> \u5b66\u7fd2\u8cc7\u6599\u3082\u9001\u4fe1\u3057\u3066\u304f\u3060\u3055\u3044 <a href=\"https:\/\/shenhengglobal.com\/ja\/contact-us\/\">\u7533\u8861\u96fb\u529b\u3078\u9023\u7d61\u3059\u308b<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Access-planning-mistakes-on-LV-boards\">Part 7. Access planning mistakes on LV boards<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Designing only for cabinet footprint without racking aisle clearance.<\/li>\n<li style=\"margin:0 0 8px\">Ordering all feeders withdrawable when many rarely need racking.<\/li>\n<li style=\"margin:0 0 8px\">Omitting spare module ratings from the RFQ.<\/li>\n<li style=\"margin:0 0 8px\">Skipping interlock demonstrations at FAT.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before operator racking drills are recorded.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3 style=\"margin:28px 0 12px\">What aisle width do withdrawable LV boards need?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Enough clear space for safe racking and door swing per the manufacturer GA and plant HSE rules \u2014 measure the room, do not assume.<\/p>\n<h3 style=\"margin:28px 0 12px\">How do interlocks protect racking operations?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">They prevent insertion\/withdrawal under unsafe breaker or shutter states; verify the logic against the ops procedure.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is fixed versus withdrawable preferred?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fixed feeders suit rarely maintained circuits; withdrawable suits feeders that need fast module swap under a planned maintenance philosophy.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which arc and segregation notes belong on the GA?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Short-circuit withstand, form of separation, and any arc claims should appear on controlled drawings.<\/p>\n<h3 style=\"margin:28px 0 12px\">What spare drawer strategy should RFQs include?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">List critical feeder ratings, quantities, and lead times so outages are not limited by missing modules.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which FAT checks prove service access before shipment?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mechanical racking, shutter coverage, and interlock demonstrations agreed in the FAT plan.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439 low-voltage switchgear assemblies<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE LV distribution equipment references<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Plan withdrawable LV Switchgear service access with compartment layout, interlocking, arc boundaries, and RFQ documents for industrial GGD\/MNS boards.<\/p>","protected":false},"author":1,"featured_media":1381,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/comments?post=2018"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/2018\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media\/1381"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media?parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/categories?post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/tags?post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}