{"id":1998,"date":"2026-08-03T14:00:00","date_gmt":"2026-08-03T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/load-break-switch-rmu-selection-guide\/"},"modified":"2026-08-03T14:00:00","modified_gmt":"2026-08-03T06:00:00","slug":"load-break-switch-rmu-selection-guide","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/ja\/blog\/load-break-switch-rmu-selection-guide\/","title":{"rendered":"Load Break Switch RMU: Selection Guide for Cable Rings"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Network planners selecting a <strong>load break switch<\/strong> inside an RMU must separate normal load switching duty from fault-making and fuse\/breaker protection roles before comparing outdoor cable-ring quotations.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This load break switch guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>load-break-switch-rmu-selection-guide<\/code> \u2014\u305d\u308c\u306f\u3001\u96fb\u529b\u4f1a\u793e\u3084\u30b3\u30f3\u30b5\u30eb\u30bf\u30f3\u30c8\u306e\u627f\u8a8d\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"load break switch planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u76ee\u6b21<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Part 1. Load break duty versus protection roles on cable rings<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Load-Break-Switch-inputs-to-lock-early\">Part 2. Load Break Switch inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Part 3. Outdoor cable entry, grounding, and gas handling<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-RMU-RFQ-pack-for-load-break-applications\">Part 4. RMU RFQ pack for load break applications<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Commissioning-checks-before-ring-energization\">Part 5. Commissioning checks before ring energization<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Load-Break-Switch-catalog-starting-point\">Part 6. Load Break Switch catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Part 7. Buyer mistakes on load break RMU orders<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Load-break-duty-versus-protection-roles-on-cable-rings\">Part 1. Load break duty versus protection roles on cable rings<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A load break switch is sized for switching load current under defined conditions \u2014 it is not automatically a short-circuit interrupter. Ring schemes often combine load break ways with fuse-switch or circuit-breaker functions on transformer feeders.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Write the functional role of each way on the single-line so vendors cannot substitute a look-alike cubicle with the wrong duty class.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u95a2\u9023\u8aad\u66f8\uff1a <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/ring-main-unit-rmu-selection-guide\/\">ring main unit RMU selection guide<\/a> \u305d\u3057\u3066 <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/outdoor-ring-main-unit-cable-entry-planning\/\">outdoor ring main unit cable entry planning<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Load-Break-Switch-inputs-to-lock-early\">Part 2. Load Break Switch inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Selection input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Network risk if vague<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u6240\u6709\u8005<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated voltage \/ insulation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong clearance class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Network SLD<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Load break current rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe switching duty<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Operating study<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-time \/ fault-making rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle damage on faults<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u6545\u969c\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Number of ring \/ tee ways<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong enclosure footprint<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Feeder plan<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable type and entry direction<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil trench rework<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable design<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SF6 \/ alternative gas notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Handling &amp; environmental compliance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">HSE \/ ops<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Motorization \/ remote control<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SCADA interface gap<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Automation team<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"load break switch specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u91cd\u8981\uff1a<\/strong> For load break switch, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC\u898f\u683c\u306e\u5b9f\u8df5<\/a> \u305d\u3057\u3066\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u6a29\u9650\u306e\u30bd\u30fc\u30b9\u30ce\u30fc\u30c8\u3002.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Outdoor-cable-entry-,-grounding-,-and-gas-handling\">Part 3. Outdoor cable entry, grounding, and gas handling<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Outdoor RMUs need gland plates and bending radii that match MV cable specs. Grounding continuity between tank, cable screens, and the earthing grid should be verified before backfill.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If SF6 is used, retain handling, leak-check, and end-of-life recovery notes in the O&amp;M pack \u2014 treat them as controlled environmental documents.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-RMU-RFQ-pack-for-load-break-applications\">Part 4. RMU RFQ pack for load break applications<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u76ee\u7684<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u5f15\u7528\u4ed8\u304d\u3067\u9001\u4fe1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Way function matrix (LBS \/ fuse \/ CB)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Duty clarity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated currents and fault duties<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Network match<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 study refs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry GA and gland schedule<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before PO<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gas type and handling procedure<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">HSE compliance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 with O&amp;M<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and earthing notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe operation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops sign-off<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Routine test certificates<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Factory evidence<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 FAT list<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Remote \/ motor option datasheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SCADA integration<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">If specified<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u30d9\u30f3\u30c0\u30fc\u304c\u30ab\u30bf\u30ed\u30b0\u306e\u629c\u7c8b\u3067\u306f\u306a\u304f\u6bd4\u8f03\u53ef\u80fd\u306a\u6280\u8853\u30d1\u30c3\u30b1\u30fc\u30b8\u3092\u63d0\u51fa\u3059\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30c6\u30fc\u30d6\u30eb\u3092\u3059\u3079\u3066\u306eRFQ\u6539\u8a02\u7248\u306b\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Commissioning-checks-before-ring-energization\">Part 5. Commissioning checks before ring energization<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Verify mechanical operation of each load break way, earthing switch position indications, and cable sheath bonds. Record gas pressure (where applicable) against the nameplate band.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Do not close onto a live ring until protection on tee-offs is proven and the operating sequence is filed with the control room.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Load-Break-Switch-catalog-starting-point\">Part 6. Load Break Switch catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many load break switch scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/ja\/product\/ring-main-unit-rmu-sf6-gas-insulated-mv-switchgear\/\">SF6 gas insulated ring main unit (RMU)<\/a> \u88fd\u54c1\u30da\u30fc\u30b8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30ab\u30bf\u30ed\u30b0\u30a8\u30f3\u30c8\u30ea\u30fc\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"SF6 gas insulated ring main unit (RMU) for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.Ring-Main-Unit-RMU-MV-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5236\u9650\uff1a<\/strong> \u306e\u305f\u3081\u306e <code>load break switch<\/code> (<code>load-break-switch-rmu-selection-guide<\/code>)\u3001\u30ea\u30f3\u30af\u3055\u308c\u305f\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u306f\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u306e\u51fa\u767a\u70b9\u3068\u3057\u3066\u306e\u307f\u6271\u3063\u3066\u304f\u3060\u3055\u3044\u3002 <strong>\u3067\u306f\u306a\u3044<\/strong> \u30d5\u30ea\u30fc\u30ba <code>load break switch<\/code> \u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u6545\u969c\u30b9\u30bf\u30c7\u30a3\u3001\u9ad8\u5ea6\u30c7\u30a3\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u307e\u305f\u306f\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u306e\u578b\u5f0f\u627f\u8a8d\u306e\u5305\u7d61\u7dda\u304c\u3001\u8a72\u5f53\u3059\u308b\u88fd\u54c1\u30da\u30fc\u30b8\u306e\u516c\u958b\u5b9a\u683c\u3092\u8d85\u904e\u3059\u308b\u5834\u5408\u306e\u8abf\u9054\u3002.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the load break switch study points to a different scheme or rating for load-break-switch-rmu-selection-guide, browse the <a href=\"https:\/\/shenhengglobal.com\/ja\/medium-voltage-switchgear\/\">\u30ab\u30c6\u30b4\u30ea\u30da\u30fc\u30b8<\/a> \u5b66\u7fd2\u8cc7\u6599\u3082\u9001\u4fe1\u3057\u3066\u304f\u3060\u3055\u3044 <a href=\"https:\/\/shenhengglobal.com\/ja\/contact-us\/\">\u7533\u8861\u96fb\u529b\u3078\u9023\u7d61\u3059\u308b<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Buyer-mistakes-on-load-break-RMU-orders\">Part 7. Buyer mistakes on load break RMU orders<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Treating every RMU way as a fault interrupter.<\/li>\n<li style=\"margin:0 0 8px\">Leaving feeder count as &#8220;typical three-way&#8221; without a locked matrix.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring cable entry direction until the pad is poured.<\/li>\n<li style=\"margin:0 0 8px\">Omitting SF6 handling documents from the contract annex.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before earthing indications are verified.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3 style=\"margin:28px 0 12px\">How does a load break switch differ from a fault-making switch?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Load break covers defined load-current switching; fault-making and interrupting duties require ratings proven for short-circuit conditions.<\/p>\n<h3 style=\"margin:28px 0 12px\">What feeder count should buyers freeze on an RMU RFQ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Freeze ring and tee ways on a function matrix tied to the network plan before requesting enclosure GA drawings.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is SF6 RMU preferred for outdoor cable rings?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">When compact outdoor footprints and proven gas-insulated modules fit the site \u2014 still subject to local environmental handling rules.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which fault ratings must match the network study?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Short-time withstand and any fault-making claims must match prospective fault levels at the installation point.<\/p>\n<h3 style=\"margin:28px 0 12px\">What cable entry details stall outdoor RMU installs?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Gland plate size, entry direction, and bending radius mismatches with trenches or ducts.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which documents should accompany SF6 handling notes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Leak-check procedures, recovery requirements, and O&amp;M references should travel with the equipment dossier.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271 switchgear publications<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE distribution switchgear references<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Select a load break switch RMU with feeder count, fault duty, cable entry design, SF6 handling notes, and RFQ documents for MV cable ring networks.<\/p>","protected":false},"author":1,"featured_media":1394,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1998","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/comments?post=1998"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1998\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media\/1394"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media?parent=1998"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/categories?post=1998"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/tags?post=1998"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}