{"id":1986,"date":"2026-08-02T09:00:00","date_gmt":"2026-08-02T01:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/500-kva-transformer-selection-guide\/"},"modified":"2026-08-02T09:00:00","modified_gmt":"2026-08-02T01:00:00","slug":"500-kva-transformer-selection-guide","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/ja\/blog\/500-kva-transformer-selection-guide\/","title":{"rendered":"500 kVA Transformer: Selection Inputs for EPC Feeders"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">EPC teams sizing a <strong>500 kVA transformer<\/strong> for industrial feeders, commercial campuses, or renewable collection points often see quotes that match on kVA but diverge on impedance, loss temperature basis, and enclosure class.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This 500 kva transformer guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>500-kva-transformer-selection-guide<\/code> \u2014\u305d\u308c\u306f\u3001\u96fb\u529b\u4f1a\u793e\u3084\u30b3\u30f3\u30b5\u30eb\u30bf\u30f3\u30c8\u306e\u627f\u8a8d\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"500 kva transformer planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.-3-Phase-Cast-Resin-Dry-Type-Transformer.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u76ee\u6b21<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Where-500-kVA-sits-between-small-and-mid-size-feeders\">Part 1. Where 500 kVA sits between small and mid-size feeders<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-500-Kva-Transformer-inputs-to-lock-early\">Part 2. 500 Kva Transformer inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Cast-resin-indoor-versus-oil-immersed-outdoor-boundaries\">Part 3. Cast resin indoor versus oil immersed outdoor boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Factory-documents-to-attach-to-every-500-kVA-RFQ\">Part 4. Factory documents to attach to every 500 kVA RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Installation-and-energization-checks-at-500-kVA\">Part 5. Installation and energization checks at 500 kVA<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-500-Kva-Transformer-catalog-starting-point\">Part 6. 500 Kva Transformer catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Mistakes-that-delay-500-kVA-awards\">Part 7. Mistakes that delay 500 kVA awards<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Where-500-kVA-sits-between-small-and-mid-size-feeders\">Part 1. Where 500 kVA sits between small and mid-size feeders<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A 500 kVA rating commonly bridges light commercial pads and heavier industrial incomers. Fault contribution at the LV board rises with the unit size, so cable and breaker ratings must be rechecked even when the legacy nameplate also read &#8220;about half a megawatt.&#8221;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Buyers should map diversity assumptions from the load study to the chosen kVA step before freezing the purchase order. Stepping from 400 to 500 kVA without updating loss targets or tap range can trigger utility rework later.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u95a2\u9023\u8aad\u66f8\uff1a <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/distribution-transformer-rfq-checklist\/\">\u914d\u96fb\u7528\u5909\u5727\u5668\u898b\u7a4d\u4f9d\u983c\u4ed5\u69d8\u66f8\u30c1\u30a7\u30c3\u30af\u30ea\u30b9\u30c8<\/a> \u305d\u3057\u3066 <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/100-kva-transformer-selection-guide\/\">100 kVA transformer selection guide<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-500-Kva-Transformer-inputs-to-lock-early\">Part 2. 500 Kva Transformer inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Input at 500 kVA<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Why bids stall without it<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u6240\u6709\u8005<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Primary \/ secondary voltage<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sets winding and BIL class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u5358\u7dda\u7d50\u7dda\u56f3<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u7d50\u7dda\u56f3\u8a18\u53f7<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grounding and relay polarity<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Utility \/ protection note<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Impedance (%Z) at reference temp<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">LV fault contribution<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u6545\u969c\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">No-load and load loss targets<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Operating cost and utility forms<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Consultant loss sheet<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cooling class (AN\/AF or ONAN)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room ventilation or oil containment<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Mechanical engineer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Enclosure \/ IP and noise limit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Indoor occupied-space fit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil \/ ops<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Altitude and ambient<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Derating and cooling margin<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u30b5\u30a4\u30c8\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"500 kva transformer specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.-3-Phase-Cast-Resin-Dry-Type-Transformer.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u91cd\u8981\uff1a<\/strong> For 500 kva transformer, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC\u898f\u683c\u306e\u5b9f\u8df5<\/a> \u305d\u3057\u3066\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u6a29\u9650\u306e\u30bd\u30fc\u30b9\u30ce\u30fc\u30c8\u3002.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Cast-resin-indoor-versus-oil-immersed-outdoor-boundaries\">Part 3. Cast resin indoor versus oil immersed outdoor boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">At 500 kVA, indoor <strong>cast resin dry type<\/strong> units reduce oil handling inside occupied buildings, while outdoor <strong>oil immersed<\/strong> packages remain common on utility pads with bunding and standard ONAN practice.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Record filter clearance, room heat rejection, and classified-area limits for dry type rooms. For oil immersed pads, confirm lifting paths, sampling ports, and fire separation before GA release.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Factory-documents-to-attach-to-every-500-kVA-RFQ\">Part 4. Factory documents to attach to every 500 kVA RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u66f8\u985e \/ \u9805\u76ee<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u76ee\u7684<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u5f15\u7528\u4ed8\u304d\u3067\u9001\u4fe1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Routine \/ type test summary<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Loss and impedance basis<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before award<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">GA drawing with weights<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pad and lifting plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 design freeze<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Terminal \/ cable entry drawing<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">LV gland and CT placement<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u306f\u3044\u3001\u88fd\u9020\u306e\u524d\u306b<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tap chart and vector confirmation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning reference<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 with FAT plan<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Noise \/ cooling data sheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room HVAC sizing<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 when indoor<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">O&amp;M manual + spare list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Handover and stocking<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 contract schedule<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ratio \/ polarity test sheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Energization dossier<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u30d9\u30f3\u30c0\u30fc\u304c\u30ab\u30bf\u30ed\u30b0\u306e\u629c\u7c8b\u3067\u306f\u306a\u304f\u6bd4\u8f03\u53ef\u80fd\u306a\u6280\u8853\u30d1\u30c3\u30b1\u30fc\u30b8\u3092\u63d0\u51fa\u3059\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30c6\u30fc\u30d6\u30eb\u3092\u3059\u3079\u3066\u306eRFQ\u6539\u8a02\u7248\u306b\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Installation-and-energization-checks-at-500-kVA\">Part 5. Installation and energization checks at 500 kVA<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Confirm grounding, cable torque, and surge protection against the released drawing. Dry type rooms need clear filter access; oil units need silica gel and pressure-relief checks before first energization.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Commissioning should include ratio, polarity, insulation resistance, and protection functional tests tied to the approved settings sheet.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-500-Kva-Transformer-catalog-starting-point\">Part 6. 500 Kva Transformer catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many 500 kva transformer scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/ja\/product\/11kv-500kva-1500kva-3-phase-cast-resin-dry-type-transformer\/\">11kV cast resin dry type transformer (500\u20131500 kVA)<\/a> \u88fd\u54c1\u30da\u30fc\u30b8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30ab\u30bf\u30ed\u30b0\u30a8\u30f3\u30c8\u30ea\u30fc\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"11kV cast resin dry type transformer (500\u20131500 kVA) for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.-3-Phase-Cast-Resin-Dry-Type-Transformer.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5236\u9650\uff1a<\/strong> \u306e\u305f\u3081\u306e <code>500 kva transformer<\/code> (<code>500-kva-transformer-selection-guide<\/code>)\u3001\u30ea\u30f3\u30af\u3055\u308c\u305f\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u306f\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u306e\u51fa\u767a\u70b9\u3068\u3057\u3066\u306e\u307f\u6271\u3063\u3066\u304f\u3060\u3055\u3044\u3002 <strong>\u3067\u306f\u306a\u3044<\/strong> \u30d5\u30ea\u30fc\u30ba <code>500 kva transformer<\/code> \u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u6545\u969c\u30b9\u30bf\u30c7\u30a3\u3001\u9ad8\u5ea6\u30c7\u30a3\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u307e\u305f\u306f\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u306e\u578b\u5f0f\u627f\u8a8d\u306e\u5305\u7d61\u7dda\u304c\u3001\u8a72\u5f53\u3059\u308b\u88fd\u54c1\u30da\u30fc\u30b8\u306e\u516c\u958b\u5b9a\u683c\u3092\u8d85\u904e\u3059\u308b\u5834\u5408\u306e\u8abf\u9054\u3002.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the 500 kva transformer study points to a different scheme or rating for 500-kva-transformer-selection-guide, browse the <a href=\"https:\/\/shenhengglobal.com\/ja\/dry-type-transformer\/\">\u30ab\u30c6\u30b4\u30ea\u30da\u30fc\u30b8<\/a> \u5b66\u7fd2\u8cc7\u6599\u3082\u9001\u4fe1\u3057\u3066\u304f\u3060\u3055\u3044 <a href=\"https:\/\/shenhengglobal.com\/ja\/contact-us\/\">\u7533\u8861\u96fb\u529b\u3078\u9023\u7d61\u3059\u308b<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Mistakes-that-delay-500-kVA-awards\">Part 7. Mistakes that delay 500 kVA awards<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Comparing quotes without the same loss temperature and impedance base.<\/li>\n<li style=\"margin:0 0 8px\">Omitting vector group and tap range when the utility note already defines them.<\/li>\n<li style=\"margin:0 0 8px\">Selecting indoor dry type without verifying ventilation in the room layout.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before ratio\/polarity results are filed with protection settings.<\/li>\n<li style=\"margin:0 0 8px\">Copying a smaller-unit RFQ template without updating fault-level inputs.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3 style=\"margin:28px 0 12px\">When is 500 kVA the right step versus 400 or 630 kVA?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Choose the step that matches the diversity-adjusted load study and leaves acceptable fault levels on the LV board \u2014 not a round marketing number.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which loss basis should bidders use at 500 kVA?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Require the same reference temperature and guaranteed no-load\/load loss format across all bidders before commercial comparison.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does indoor cast resin fit most 500 kVA plant rooms?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Only when heat rejection, filter clearance, and fire rules fit the room layout; otherwise evaluate outdoor oil immersed pads.<\/p>\n<h3 style=\"margin:28px 0 12px\">What impedance range matters for LV board bracing?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use the study %Z to recalculate prospective fault current; do not assume the previous unit&#8217;s impedance still applies.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which factory documents belong in the RFQ pack?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Attach test summaries, GA weights, terminal drawings, tap charts, and commissioning sheets so vendors return comparable binders.<\/p>\n<h3 style=\"margin:28px 0 12px\">When should utility tap settings be locked before manufacture?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Before winding release whenever seasonal voltage or new upstream generation can shift the operating band.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/5998\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1 \u96fb\u529b\u7528\u5909\u5727\u5668 \u2014 \u4e00\u822c<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE distribution transformer practice portal<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Specify a 500 kVA transformer with voltage class, vector group, losses, cooling, enclosure IP, and RFQ documents EPC teams need before bid comparison.<\/p>","protected":false},"author":1,"featured_media":1409,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/comments?post=1986"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1986\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media\/1409"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media?parent=1986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/categories?post=1986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/tags?post=1986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}