{"id":1984,"date":"2026-08-02T14:00:00","date_gmt":"2026-08-02T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/12kv-metal-clad-switchgear-layout-checklist\/"},"modified":"2026-08-02T14:00:00","modified_gmt":"2026-08-02T06:00:00","slug":"12kv-metal-clad-switchgear-layout-checklist","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/ja\/blog\/12kv-metal-clad-switchgear-layout-checklist\/","title":{"rendered":"12kV Metal Clad Switchgear: Layout Checklist for MV Rooms"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Project engineers laying out <strong>12kV metal clad switchgear<\/strong> need more than a catalog cubicle count \u2014 cable entry, busbar rating, arc boundaries, and relay interfaces must fit the approved single-line and room geometry.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This 12kv metal clad switchgear guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>12kv-metal-clad-switchgear-layout-checklist<\/code> \u2014\u305d\u308c\u306f\u3001\u96fb\u529b\u4f1a\u793e\u3084\u30b3\u30f3\u30b5\u30eb\u30bf\u30f3\u30c8\u306e\u627f\u8a8d\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"12kv metal clad switchgear planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/4.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u76ee\u6b21<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Why-layout-freezes-before-commercial-award\">Part 1. Why layout freezes before commercial award<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-12Kv-Metal-Clad-Switchgear-inputs-to-lock-early\">Part 2. 12Kv Metal Clad Switchgear inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Room-geometry-,-cable-routes-,-and-arc-boundaries\">Part 3. Room geometry, cable routes, and arc boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Drawings-and-data-to-require-with-each-panel-RFQ\">Part 4. Drawings and data to require with each panel RFQ<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Factory-acceptance-and-site-racking-checks\">Part 5. Factory acceptance and site racking checks<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-12Kv-Metal-Clad-Switchgear-catalog-starting-point\">Part 6. 12Kv Metal Clad Switchgear catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Layout-mistakes-that-force-rework\">Part 7. Layout mistakes that force rework<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Why-layout-freezes-before-commercial-award\">Part 1. Why layout freezes before commercial award<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Metal clad boards define aisle widths, pressure relief paths, and maintenance access for decades. Changing cable entry after manufacture often forces civil and protection rework.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Treat the layout checklist as a design control document: every revision must reconcile feeder names, CT ratios, and interlocking notes with the latest single-line revision.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u95a2\u9023\u8aad\u66f8\uff1a <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/metal-clad-switchgear-arc-mitigation-overview\/\">metal clad switchgear arc mitigation overview<\/a> \u305d\u3057\u3066 <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/kyn28-switchgear-interlock-verification\/\">KYN28 \u5236\u5fa1\u76e4\u30a4\u30f3\u30bf\u30fc\u30ed\u30c3\u30af\u691c\u8a3c<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-12Kv-Metal-Clad-Switchgear-inputs-to-lock-early\">Part 2. 12Kv Metal Clad Switchgear inputs to lock early<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Layout input<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Failure mode if omitted<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u6240\u6709\u8005<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rated voltage \/ insulation level<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong clearance class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u5358\u7dda\u7d50\u7dda\u56f3<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Main busbar continuous rating<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thermal overload on future feeders<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Load schedule<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Short-time withstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Busbar bracing inadequacy<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u6545\u969c\u89e3\u6790<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry (rear \/ bottom \/ side)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil trench mismatch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable design<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc classification \/ relief path<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe personnel aisle<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection \/ safety<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">CT\/VT and relay interface list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection settings delay<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u30ea\u30ec\u30fc\u30a8\u30f3\u30b8\u30cb\u30a2<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock and earthing switch notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Unsafe racking sequences<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ops \/ manufacturer<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"12kv metal clad switchgear specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/5.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u91cd\u8981\uff1a<\/strong> For 12kv metal clad switchgear, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC\u898f\u683c\u306e\u5b9f\u8df5<\/a> \u305d\u3057\u3066\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u6a29\u9650\u306e\u30bd\u30fc\u30b9\u30ce\u30fc\u30c8\u3002.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Room-geometry-,-cable-routes-,-and-arc-boundaries\">Part 3. Room geometry, cable routes, and arc boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Confirm front and rear aisle widths, door swing, and lifting height before ordering. Bottom-entry designs need trench depth and bending radius that match MV cable specs.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Arc-mitigation ducts or relief flaps must terminate outdoors or into approved zones \u2014 never into occupied corridors without a documented study.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Drawings-and-data-to-require-with-each-panel-RFQ\">Part 4. Drawings and data to require with each panel RFQ<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"\u30b9\u30af\u30ed\u30fc\u30eb\u53ef\u80fd\u306a\u30c7\u30fc\u30bf\u30c6\u30fc\u30d6\u30eb\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Drawing \/ data pack<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u76ee\u7684<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u5f15\u7528\u4ed8\u304d\u3067\u9001\u4fe1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cubicle arrangement GA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Room and aisle fit<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 with revision<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Single-line with CT\/VT ratios<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection coordination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked revision<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and gland plate detail<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Trench \/ tray interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u306f\u3044\u3001\u88fd\u9020\u306e\u524d\u306b<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Interlock logic description<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safe racking sequence<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 ops review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Arc relief path sketch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Safety acceptance<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 when IAC claimed<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">FAT \/ routine test plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Witness schedule<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 contract annex<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nameplate and relay setting sheet<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Commissioning dossier<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u30d9\u30f3\u30c0\u30fc\u304c\u30ab\u30bf\u30ed\u30b0\u306e\u629c\u7c8b\u3067\u306f\u306a\u304f\u6bd4\u8f03\u53ef\u80fd\u306a\u6280\u8853\u30d1\u30c3\u30b1\u30fc\u30b8\u3092\u63d0\u51fa\u3059\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30c6\u30fc\u30d6\u30eb\u3092\u3059\u3079\u3066\u306eRFQ\u6539\u8a02\u7248\u306b\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Factory-acceptance-and-site-racking-checks\">Part 5. Factory acceptance and site racking checks<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Witness mechanical racking, interlock defeat attempts, and primary injection where the contract requires it. On site, verify earthing switches, shutter operation, and CT polarity before first energization.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">File as-built GA revisions with the protection settings pack so future feeder additions start from evidence rather than memory.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-12Kv-Metal-Clad-Switchgear-catalog-starting-point\">Part 6. 12Kv Metal Clad Switchgear catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many 12kv metal clad switchgear scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/ja\/product\/customized-gas-insulated-switchgear-kyn28-12-12kv-24kv-switchgear-system\/\">KYN28-12\u9ad8\u5727\u53d7\u914d\u96fb\u76e4\u30b7\u30b9\u30c6\u30e0<\/a> \u88fd\u54c1\u30da\u30fc\u30b8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30ab\u30bf\u30ed\u30b0\u30a8\u30f3\u30c8\u30ea\u30fc\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"KYN28-12 medium voltage switchgear system for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.Gas-Insulated-Switchgear.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5236\u9650\uff1a<\/strong> \u306e\u305f\u3081\u306e <code>12kv metal clad switchgear<\/code> (<code>12kv-metal-clad-switchgear-layout-checklist<\/code>)\u3001\u30ea\u30f3\u30af\u3055\u308c\u305f\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u306f\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u306e\u51fa\u767a\u70b9\u3068\u3057\u3066\u306e\u307f\u6271\u3063\u3066\u304f\u3060\u3055\u3044\u3002 <strong>\u3067\u306f\u306a\u3044<\/strong> \u30d5\u30ea\u30fc\u30ba <code>12kv metal clad switchgear<\/code> \u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u6545\u969c\u30b9\u30bf\u30c7\u30a3\u3001\u9ad8\u5ea6\u30c7\u30a3\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u307e\u305f\u306f\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u306e\u578b\u5f0f\u627f\u8a8d\u306e\u5305\u7d61\u7dda\u304c\u3001\u8a72\u5f53\u3059\u308b\u88fd\u54c1\u30da\u30fc\u30b8\u306e\u516c\u958b\u5b9a\u683c\u3092\u8d85\u904e\u3059\u308b\u5834\u5408\u306e\u8abf\u9054\u3002.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the 12kv metal clad switchgear study points to a different scheme or rating for 12kv-metal-clad-switchgear-layout-checklist, browse the <a href=\"https:\/\/shenhengglobal.com\/ja\/medium-voltage-switchgear\/\">\u30ab\u30c6\u30b4\u30ea\u30da\u30fc\u30b8<\/a> \u5b66\u7fd2\u8cc7\u6599\u3082\u9001\u4fe1\u3057\u3066\u304f\u3060\u3055\u3044 <a href=\"https:\/\/shenhengglobal.com\/ja\/contact-us\/\">\u7533\u8861\u96fb\u529b\u3078\u9023\u7d61\u3059\u308b<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Layout-mistakes-that-force-rework\">Part 7. Layout mistakes that force rework<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Ordering cubicles before cable entry direction is frozen.<\/li>\n<li style=\"margin:0 0 8px\">Ignoring arc relief termination into occupied spaces.<\/li>\n<li style=\"margin:0 0 8px\">Omitting CT ratio and relay model from the RFQ package.<\/li>\n<li style=\"margin:0 0 8px\">Assuming aisle width from a previous project without measuring doors.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before interlock verification is documented.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3 style=\"margin:28px 0 12px\">What room clearances matter first for 12kV metal clad boards?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Front\/rear aisle, door swing, lifting height, and arc relief termination must fit the architectural layout before PO.<\/p>\n<h3 style=\"margin:28px 0 12px\">How should busbar rating map to the feeder schedule?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Size the main bus for continuous and future feeder growth documented on the load schedule, not only today&#8217;s connected load.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is rear cable entry preferred over bottom entry?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">When trench depth or bending radius cannot support bottom entry without violating cable manufacturer limits.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which arc-mitigation notes belong on the GA drawing?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Relief path, classification claim, and any duct termination outside occupied zones should appear on the controlled GA.<\/p>\n<h3 style=\"margin:28px 0 12px\">What relay and CT data must ship with the panel RFQ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">CT\/VT ratios, accuracy class, relay type, and wiring terminal maps so settings can be prepared in parallel with manufacture.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which factory tests should buyers witness before shipment?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Agree the FAT list early \u2014 typically mechanical interlocking, dielectric checks, and functional racking demonstrations.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC 62271 metal-enclosed switchgear family<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE switchgear standards portal<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Use this 12kV metal clad switchgear layout checklist for busbar rating, cable entry, arc mitigation, relay interfaces, and RFQ drawings before panel award.<\/p>","protected":false},"author":1,"featured_media":1391,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1984","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1984","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/comments?post=1984"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1984\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media\/1391"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media?parent=1984"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/categories?post=1984"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/tags?post=1984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}