{"id":1737,"date":"2026-08-03T09:00:00","date_gmt":"2026-08-03T01:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/box-type-substation-rfq-checklist\/"},"modified":"2026-08-24T17:51:48","modified_gmt":"2026-08-24T09:51:48","slug":"box-type-substation-rfq-checklist","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/ja\/blog\/box-type-substation-rfq-checklist\/","title":{"rendered":"Box Type Substation: RFQ Checklist for Compact Outdoor Packages"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Utility and industrial buyers specifying a <strong>box type substation<\/strong> need a controlled RFQ that aligns transformer kVA, MV switching, LV distribution, and foundation interfaces before vendors quote &#8220;similar&#8221; outdoor packages.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This box type substation guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for <code>box-type-substation-rfq-checklist<\/code> \u2014\u305d\u308c\u306f\u3001\u96fb\u529b\u4f1a\u793e\u3084\u30b3\u30f3\u30b5\u30eb\u30bf\u30f3\u30c8\u306e\u627f\u8a8d\u306b\u4ee3\u308f\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"box type substation planning overview\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"Contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u76ee\u6b21<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-When-compact-outdoor-packages-beat-stick-built-yards\">Part 1. When compact outdoor packages beat stick-built yards<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Box-Type-Substation-inputs-to-lock-early\">Part 2. Box Type Substation inputs to lock early<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-MV-,-transformer-,-and-LV-compartment-boundaries\">Part 3. MV, transformer, and LV compartment boundaries<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Documents-every-box-type-substation-RFQ-should-demand\">Part 4. Documents every box type substation RFQ should demand<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Site-set-,-cable-pull-,-and-energization-sequence\">Part 5. Site set, cable pull, and energization sequence<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Box-Type-Substation-catalog-starting-point\">Part 6. Box Type Substation catalog starting point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-RFQ-mistakes-that-create-almost-fitting-packages\">Part 7. RFQ mistakes that create &quot;almost fitting&quot; packages<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-When-compact-outdoor-packages-beat-stick-built-yards\">Part 1. When compact outdoor packages beat stick-built yards<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Factory-assembled box type substations compress schedule when sites need repeatable MV-LV nodes \u2014 industrial parks, feeder extensions, and renewable collection points.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">They still require the same engineering rigor as stick-built yards: fault level, grounding, cable bending radius, and maintenance access must be frozen before enclosure manufacture.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u95a2\u9023\u8aad\u66f8\uff1a <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/compact-substation-foundation-requirements\/\">compact substation foundation requirements<\/a> \u305d\u3057\u3066 <a href=\"https:\/\/shenhengglobal.com\/ja\/blog\/padmount-transformer-vs-compact-substation\/\">padmount transformer vs compact substation<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Box-Type-Substation-inputs-to-lock-early\">Part 2. Box Type Substation inputs to lock early<\/h2>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ field<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Why compact packages fail without it<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u6240\u6709\u8005<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">MV voltage and switching scheme<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Wrong RMU \/ breaker combination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u5358\u4e00\u7dda<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Transformer kVA and vector group<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thermal and grounding mismatch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u8ca0\u8377\u8a66\u9a13<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">LV board rating and feeder count<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Insufficient outgoing ways<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">LV schedule<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Foundation load and pad size<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil redesign after GA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil engineer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry elevations<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Trench \/ tray clash<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable design<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">IP \/ corrosion \/ ambient class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Outdoor durability gap<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Site environment<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Noise and fire separation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Community \/ plant constraints<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u30aa\u30da\u30ec\u30fc\u30b7\u30e7\u30f3 \/ HSE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"box type substation specification review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/2.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u91cd\u8981\uff1a<\/strong> For box type substation, freeze these inputs on a controlled revision before normalizing commercial bids; late changes cascade into civil, protection, and factory drawings \u2014 align with <a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC\u898f\u683c\u306e\u5b9f\u8df5<\/a> \u305d\u3057\u3066\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u6a29\u9650\u306e\u30bd\u30fc\u30b9\u30ce\u30fc\u30c8\u3002.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-MV-,-transformer-,-and-LV-compartment-boundaries\">Part 3. MV, transformer, and LV compartment boundaries<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Keep MV switching, transformer, and LV distribution compartments clearly partitioned on the GA. Maintenance doors, oil containment (if liquid-filled), and HV cable boxes must not share conflicting access paths.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">State whether the transformer is dry type or oil immersed inside the package \u2014 ventilation and bunding rules change the civil interface.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Documents-every-box-type-substation-RFQ-should-demand\">Part 4. Documents every box type substation RFQ should demand<\/h2>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Package item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u76ee\u7684<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u5f15\u7528\u4ed8\u304d\u3067\u9001\u4fe1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Overall GA with weights<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pad and crane plan<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 revision controlled<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">MV\/LV single-line inside package<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection coordination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 locked SLD<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Foundation reaction loads<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil design<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before PO<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable entry and gland schedule<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Trench interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 manufacture hold<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Transformer datasheet + losses<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Utility \/ ops review<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 bid stage<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u5de5\u5834\u30eb\u30fc\u30c1\u30f3\u8a66\u9a13\u8a08\u753b<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Witness list<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 contract annex<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Transport \/ lifting drawing<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Logistics planning<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yes \u2014 before shipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u30d9\u30f3\u30c0\u30fc\u304c\u30ab\u30bf\u30ed\u30b0\u306e\u629c\u7c8b\u3067\u306f\u306a\u304f\u6bd4\u8f03\u53ef\u80fd\u306a\u6280\u8853\u30d1\u30c3\u30b1\u30fc\u30b8\u3092\u63d0\u51fa\u3059\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30c6\u30fc\u30d6\u30eb\u3092\u3059\u3079\u3066\u306eRFQ\u6539\u8a02\u7248\u306b\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Site-set-,-cable-pull-,-and-energization-sequence\">Part 5. Site set, cable pull, and energization sequence<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Verify pad flatness, earthing grid connections, and crane radii before delivery. Pull MV and LV cables only after gland plates match the as-built elevations.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Energize after ratio\/insulation checks on the transformer and functional tests on MV switching and LV feeders per the approved sequence.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Box-Type-Substation-catalog-starting-point\">Part 6. Box Type Substation catalog starting point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">For many box type substation scopes, begin engineering review with Shenheng Power&#8217;s <a href=\"https:\/\/shenhengglobal.com\/ja\/product\/11kv-33kv-yb-series-compact-outdoor-electrical-substation\/\">YB series compact outdoor electrical substation<\/a> \u88fd\u54c1\u30da\u30fc\u30b8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30ab\u30bf\u30ed\u30b0\u30a8\u30f3\u30c8\u30ea\u30fc\u3002.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"YB series compact outdoor electrical substation for engineering review\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/3.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5236\u9650\uff1a<\/strong> \u306e\u305f\u3081\u306e <code>box type substation<\/code> (<code>box-type-substation-rfq-checklist<\/code>)\u3001\u30ea\u30f3\u30af\u3055\u308c\u305f\u30ab\u30bf\u30ed\u30b0\u30da\u30fc\u30b8\u306f\u30a8\u30f3\u30b8\u30cb\u30a2\u30ea\u30f3\u30b0\u306e\u51fa\u767a\u70b9\u3068\u3057\u3066\u306e\u307f\u6271\u3063\u3066\u304f\u3060\u3055\u3044\u3002 <strong>\u3067\u306f\u306a\u3044<\/strong> \u30d5\u30ea\u30fc\u30ba <code>box type substation<\/code> \u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306e\u6545\u969c\u30b9\u30bf\u30c7\u30a3\u3001\u9ad8\u5ea6\u30c7\u30a3\u30ec\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u307e\u305f\u306f\u30e6\u30fc\u30c6\u30a3\u30ea\u30c6\u30a3\u306e\u578b\u5f0f\u627f\u8a8d\u306e\u5305\u7d61\u7dda\u304c\u3001\u8a72\u5f53\u3059\u308b\u88fd\u54c1\u30da\u30fc\u30b8\u306e\u516c\u958b\u5b9a\u683c\u3092\u8d85\u904e\u3059\u308b\u5834\u5408\u306e\u8abf\u9054\u3002.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">If the box type substation study points to a different scheme or rating for box-type-substation-rfq-checklist, browse the <a href=\"https:\/\/shenhengglobal.com\/ja\/compact-substation\/\">\u30ab\u30c6\u30b4\u30ea\u30da\u30fc\u30b8<\/a> \u5b66\u7fd2\u8cc7\u6599\u3082\u9001\u4fe1\u3057\u3066\u304f\u3060\u3055\u3044 <a href=\"https:\/\/shenhengglobal.com\/ja\/contact-us\/\">\u7533\u8861\u96fb\u529b\u3078\u9023\u7d61\u3059\u308b<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-RFQ-mistakes-that-create-almost-fitting-packages\">Part 7. RFQ mistakes that create &#8220;almost fitting&#8221; packages<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Quoting enclosure size without foundation reaction loads.<\/li>\n<li style=\"margin:0 0 8px\">Leaving cable entry elevations as &#8220;vendor standard&#8221;.<\/li>\n<li style=\"margin:0 0 8px\">Mixing oil and dry type rules without updating civil notes.<\/li>\n<li style=\"margin:0 0 8px\">Skipping transport envelope checks for site access roads.<\/li>\n<li style=\"margin:0 0 8px\">Energizing before earthing and interlock proofs are filed.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3 style=\"margin:28px 0 12px\">What belongs in a box type substation RFQ first?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">MV\/LV scheme, transformer kVA\/vector group, foundation loads, cable interfaces, and environment class should lead the RFQ.<\/p>\n<h3 style=\"margin:28px 0 12px\">How do foundation loads affect enclosure design?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Weights and dynamic lifting cases drive pad thickness and anchor layout \u2014 late changes force civil redesign.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which MV\/LV schemes fit YB-style packages?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Typical packages combine MV RMU or breaker cubicles, a distribution transformer, and an LV board \u2014 confirm the exact scheme on the SLD.<\/p>\n<h3 style=\"margin:28px 0 12px\">What cable interfaces stall civil works most often?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Entry elevation, bending radius, and gland plate size mismatches with trenches or trays.<\/p>\n<h3 style=\"margin:28px 0 12px\">Which factory tests matter for outdoor compact units?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Routine dielectric\/mechanical checks plus transformer ratio and LV functional tests agreed in the FAT plan.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is a conventional built substation still preferred?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">When future expansion, unusual fault levels, or national type-approval rules exceed compact package envelopes.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">\u53c2\u8003\u6587\u732e<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">IEC power transformer and MV switchgear families<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE distribution equipment standards<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Utility and industrial buyers specifying a box type substation need a controlled RFQ that aligns transformer kVA, MV switching, LV distribution, and foundation interfaces before vendors quote &#8220;similar&#8221; outdoor packages. This box type substation guide focuses on practical procurement and layout controls for the package below. Pair the checklist with the approved single-line for box-type-substation-rfq-checklist \u2014 it does not replace utility or consultant sign-off. Contents Part 1. When compact outdoor packages beat stick-built yards Part 2. Box Type Substation inputs to lock early Part 3. MV, transformer, and LV compartment boundaries Part 4. Documents every box type substation RFQ should demand Part 5. Site set, cable pull, and energization sequence [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1418,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1737","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/comments?post=1737"}],"version-history":[{"count":1,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1737\/revisions"}],"predecessor-version":[{"id":1972,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/posts\/1737\/revisions\/1972"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media\/1418"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/media?parent=1737"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/categories?post=1737"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/ja\/wp-json\/wp\/v2\/tags?post=1737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}