{"id":3610,"date":"2026-11-09T08:50:41","date_gmt":"2026-11-09T00:50:41","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3610"},"modified":"2026-11-11T09:19:50","modified_gmt":"2026-11-11T01:19:50","slug":"s13-10kv-and-20kv-oil-immersed-power-distribution-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/id\/product\/s13-10kv-and-20kv-oil-immersed-power-distribution-transformers\/","title":{"rendered":"Transformator Distribusi Daya Berendam Minyak S13 10kV dan 20kV"},"content":{"rendered":"<h2>Gambaran Umum Produk &amp; Aplikasi<\/h2>\n<p>Seri S13 adalah transformator distribusi daya berendam minyak yang sepenuhnya tertutup yang dirancang untuk sistem AC dengan frekuensi terukur 50Hz dan tegangan kerja maksimum 20kV. Mereka terutama digunakan sebagai transformator distribusi di berbagai perusahaan industri, termasuk sektor minyak bumi, metalurgi, teknik kimia, tekstil, dan industri ringan, serta di lokasi dengan tingkat debu yang tinggi. Transformator ini dirancang untuk efisiensi tinggi, kerugian rendah, dan operasi yang andal, membuatnya cocok untuk instalasi dalam ruangan maupun luar ruangan (instalasi luar ruangan harus menghindari paparan langsung sinar matahari, gas korosif, atau debu, sementara instalasi dalam ruangan memerlukan ruang disipasi panas yang cukup dan jarak aman).<\/p>\n<h2>Fitur Utama &amp; Desain Struktural<\/h2>\n<p>1. Inti: Inti terbuat dari lembaran baja silikon berpermeabilitas tinggi yang diorientasikan secara butir. Mengadopsi struktur tipe baru dengan inti tumpang susun penuh dengan sambungan sudut yang lengkap. Bagian inti memiliki penampang melingkar bertingkat multi-tahap, dan penyangga memiliki penampang yang sama dengan bagian inti, memastikan efisiensi magnetik tinggi dan kerugian tanpa beban yang rendah.<\/p>\n<p>2. Gulungan: Gulungan dirancang dengan saluran minyak bergelombang, menggunakan proses impregnasi tanpa lapisan varnish dan dikencangkan dengan pita pengikat. Semua gulungan adalah kumparan konsentris. Gulungan tegangan tinggi dilengkapi dengan sambungan yang sesuai dengan tegangan sambungan yang dibutuhkan, yang terhubung ke pengubah sambungan. Pengubah sambungan dipasang di tutup tangki, dan penyesuaian tegangan sambungan hanya dapat dilakukan setelah pemadaman daya.<\/p>\n<p>3. Perangkat Perlindungan Keamanan: Transformator dengan kapasitas 30-2000 kVA dilengkapi katup pelepas tekanan. Relay gas dengan terminal alarm dan trip dapat dipasang sesuai kebutuhan pengguna.<\/p>\n<p>4. Alat Pengukur Suhu Minyak: Semua transformator dilengkapi dengan soket untuk termometer kaca, yang dipasang di bagian atas tangki minyak dan menjulur ke dalam minyak sedalam 120\u00b110 mm. Transformator dengan kapasitas 1000-2000 kVA dilengkapi dengan termometer sinyal tipe luar ruangan.<\/p>\n<p>5. Tangki Transformator: Tangki transformator dibangun dengan dinding bergelombang, dan permukaannya dilapisi dengan cat bubuk untuk daya rekat cat yang kuat. Dinding bergelombang berfungsi ganda sebagai disipasi panas dan \u201cbernapas\u201d terhadap fluktuasi volume minyak transformator yang disebabkan oleh perubahan suhu. Akibatnya, transformator yang sepenuhnya tertutup menghilangkan kebutuhan akan konservator minyak, mengurangi tinggi keseluruhan unit. Pengisian minyak vakum diterapkan selama enkapsulasi transformator untuk menghilangkan kelembapan di dalam transformator secara lengkap. Minyak transformator diisolasi dari kontak udara, secara efektif mencegah masuknya oksigen dan kelembapan yang dapat merusak kinerja isolasi dan mempercepat penuaan minyak. Oleh karena itu, pengujian sampel minyak secara rutin tidak diperlukan.<\/p>\n<p>6. Kondisi Kerja: Cocok untuk area dengan ketinggian tidak melebihi 1.000 meter, suhu lingkungan maksimum +40\u00b0C, dan suhu lingkungan minimum -25\u00b0C atau -5\u00b0C. Frekuensi terukur dari jaringan listrik yang terhubung adalah 50Hz, dan rentang fluktuasi tegangan pasokan tidak boleh melebihi \u00b15% dari tegangan terukur. Tingkat distorsi gelombang harus memenuhi persyaratan manajemen harmonik dari sistem tenaga. Transformator dapat dipasang di luar ruangan maupun di dalam ruangan di tempat yang memiliki ventilasi baik. Untuk pemasangan luar ruangan, harus dihindari paparan langsung sinar matahari, gas korosif, atau penumpukan debu; untuk pemasangan dalam ruangan, harus dipastikan ruang disipasi panas yang cukup dan jarak aman. Transformator diizinkan beroperasi secara terus-menerus dalam kapasitas terukur dan memiliki kapasitas beban sementara tertentu. Jika digunakan di lingkungan khusus seperti daerah rawan petir, kelembapan tinggi, polusi berat, korosi kimia, atau zona seismik, pemberitahuan sebelumnya harus diberikan, dan skema perlindungan yang ditingkatkan harus disediakan.<\/p>\n<h2>Parameter Produk<\/h2>\n<table style=\"border-collapse: collapse; width: 50.2877%; height: 604px;\" border=\"0\" width=\"648\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 54.00pt; width: 54.00pt;\" rowspan=\"4\" width=\"72\" height=\"72\">Nominal<br \/>\nKapasitas<br \/>\n(kVA)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Tinggi<br \/>\nTegangan<br \/>\n(KV)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Tegangan tinggi<br \/>\nRentang tapping<br \/>\n(%)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Rendah<br \/>\nTegangan<br \/>\n(kV)<\/td>\n<td class=\"et2\" style=\"width: 162.00pt;\" colspan=\"3\" width=\"216\">S13-M<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Tanpa beban<br \/>\narus<br \/>\n(%)<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Hubung singkat<br \/>\nimpedansi%<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" colspan=\"3\">Baja strip listrik<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td rowspan=\"2\">Kerugian tanpa beban kW<\/td>\n<td colspan=\"2\">Kerugian beban penuh kW<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td>Dyn11\/Yzn11<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">30<\/td>\n<td rowspan=\"19\">63<br \/>\n10<br \/>\n10.5<\/td>\n<td rowspan=\"19\">\u00b12\u00d72.5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\" align=\"right\">0.4<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">630<\/td>\n<td align=\"right\">710<\/td>\n<td align=\"right\">1.2<\/td>\n<td rowspan=\"12\" align=\"right\">4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">50<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">910<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">1.04<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">63<\/td>\n<td align=\"right\">110<\/td>\n<td align=\"right\">1090<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">80<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">1310<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">100<\/td>\n<td align=\"right\">150<\/td>\n<td align=\"right\">1580<\/td>\n<td align=\"right\">1570<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">125<\/td>\n<td align=\"right\">170<\/td>\n<td align=\"right\">1890<\/td>\n<td align=\"right\">1850<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">160<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2310<\/td>\n<td align=\"right\">2130<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">200<\/td>\n<td align=\"right\">240<\/td>\n<td align=\"right\">2730<\/td>\n<td align=\"right\">2530<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">250<\/td>\n<td align=\"right\">290<\/td>\n<td align=\"right\">3200<\/td>\n<td align=\"right\">2760<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">315<\/td>\n<td align=\"right\">340<\/td>\n<td align=\"right\">3830<\/td>\n<td align=\"right\">3470<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">400<\/td>\n<td align=\"right\">410<\/td>\n<td align=\"right\">4520<\/td>\n<td align=\"right\">3990<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">500<\/td>\n<td align=\"right\">480<\/td>\n<td align=\"right\">5410<\/td>\n<td align=\"right\">4880<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">630<\/td>\n<td align=\"right\">570<\/td>\n<td colspan=\"2\" align=\"right\">6200<\/td>\n<td align=\"right\">0.48<\/td>\n<td rowspan=\"5\" align=\"right\">4.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">800<\/td>\n<td align=\"right\">700<\/td>\n<td colspan=\"2\" align=\"right\">7500<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1000<\/td>\n<td align=\"right\">830<\/td>\n<td colspan=\"2\" align=\"right\">10300<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1250<\/td>\n<td align=\"right\">970<\/td>\n<td colspan=\"2\" align=\"right\">12000<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1600<\/td>\n<td align=\"right\">1170<\/td>\n<td colspan=\"2\" align=\"right\">14500<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2000<\/td>\n<td align=\"right\">1360<\/td>\n<td colspan=\"2\" align=\"right\">18300<\/td>\n<td align=\"right\">0.32<\/td>\n<td rowspan=\"2\" align=\"right\">5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2500<\/td>\n<td align=\"right\">1600<\/td>\n<td colspan=\"2\" align=\"right\">21200<\/td>\n<td align=\"right\">0.32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Rincian Aplikasi<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3861\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3862\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3863\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3864\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Seri S13 adalah transformator berendam minyak yang sepenuhnya tertutup dan cocok untuk sistem tenaga dengan frekuensi AC 50Hz dan tegangan kerja terukur 20kV atau kurang. Mereka digunakan sebagai transformator distribusi di perusahaan seperti minyak bumi, metalurgi, teknik kimia, tekstil, dan industri ringan, serta di tempat dengan jumlah debu yang besar. Transformator ini dilengkapi inti yang sangat andal terbuat dari lembaran baja silikon berpermeabilitas tinggi yang diorientasikan secara butir, sistem isolasi canggih, dan desain tangki minyak yang sepenuhnya tertutup, memastikan operasi bebas perawatan dan umur layanan yang panjang.<\/p>","protected":false},"featured_media":3611,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3610","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/comments?post=3610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/media\/3611"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_brand?post=3610"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_cat?post=3610"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_tag?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}