{"id":3574,"date":"2026-11-07T17:13:40","date_gmt":"2026-11-07T09:13:40","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3574"},"modified":"2026-11-11T10:06:29","modified_gmt":"2026-11-11T02:06:29","slug":"sbh15-10kv-oil-immersed-amorphous-alloy-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/id\/product\/sbh15-10kv-oil-immersed-amorphous-alloy-transformers\/","title":{"rendered":"Transformator Amorf Alloy Oli-Immersed S(B)H15 10kV"},"content":{"rendered":"<h2>Gambaran Umum Produk &amp; Aplikasi<\/h2>\n<p>Seri S(B)H15 adalah transformator paduan amorf 10kV berefisiensi tinggi yang dilapisi minyak. Fungsi utamanya adalah mengubah tegangan jaringan ke tingkat yang dibutuhkan oleh sistem atau beban, memungkinkan transmisi dan distribusi energi listrik. Menggantikan transformator inti baja silikon tradisional, produk ini banyak digunakan dalam sistem distribusi daya luar ruangan. Penggunaan inti paduan amorf mencapai efek penghematan energi yang luar biasa dan mengurangi pencemaran atmosfer, menjadikannya sangat cocok untuk daerah dengan pasokan listrik yang tidak mencukupi, fluktuasi beban yang besar, dan pemeliharaan rutin yang sulit. Struktur yang sepenuhnya tertutup memastikan bahwa minyak isolasi dan bahan dielektrik terlindungi dari kontaminasi atmosfer, memungkinkan operasi yang andal di lingkungan lembab. Mereka adalah peralatan distribusi daya yang ideal untuk jaringan distribusi perkotaan dan pedesaan.<\/p>\n<h2>Fitur Utama &amp; Desain Struktural<\/h2>\n<p>1. Efisiensi Energi Ultra-Tinggi: Menggunakan inti paduan amorf, kerugian tanpa beban sekitar 60%\u201380% lebih rendah dibandingkan transformator lembar baja silikon konvensional. Hal ini membuatnya sangat cocok untuk skenario dengan fluktuasi tingkat beban yang besar, operasi beban ringan jangka panjang, atau tanpa beban, memberikan manfaat ekonomi yang luar biasa sepanjang masa layanan.<\/p>\n<p>2. Keandalan Tinggi: Mengadopsi struktur tangki minyak tertutup penuh (biasanya tangki bergelombang), menghilangkan kontak antara minyak isolasi dan udara. Ini mencegah degradasi minyak, memperpanjang interval pemeliharaan, dan memastikan umur layanan yang panjang.<\/p>\n<p>3. Aman Lingkungan: Paduan amorf adalah bahan ramah lingkungan dengan konsumsi energi rendah dalam produksinya. Minyak transformator biasanya minyak mineral berkinerja tinggi atau minyak ester alami yang dapat terurai, memenuhi persyaratan perlindungan lingkungan.<\/p>\n<p>4. Kokoh dan Tahan Lama: Desain struktural kompak dengan kekuatan mekanik tinggi. Kelas perlindungan umumnya mencapai IP54 atau lebih tinggi, secara efektif melawan debu, kelembapan, dan lingkungan luar yang keras.<\/p>\n<p>5. Operasi Berisik Rendah: Efek magnetostriksi dari inti paduan amorf jauh lebih rendah dibandingkan lembar baja silikon, menghasilkan kebisingan yang lebih rendah selama operasi transformator. Hal ini membuatnya lebih cocok untuk area yang sensitif terhadap kebisingan seperti kawasan pemukiman, rumah sakit, dan sekolah.<\/p>\n<p>6. Adaptasi Cerdas: Pemantauan suhu minyak terintegrasi, katup pelepas tekanan, pemantauan daring, dan perangkat perlindungan, seperti relay gas untuk pemantauan kondisi cerdas dan peringatan dini kerusakan jaringan distribusi, untuk memberikan dukungan.<\/p>\n<p>7. Kondisi Lingkungan: Rentang suhu lingkungan untuk operasi normal adalah -25\u00b0C hingga +40\u00b0C, dengan suhu rata-rata harian maksimum tidak melebihi +30\u00b0C. Ketinggian \u2264 1000 m. Tangki minyak tertutup penuh dan lapisan anti karat memastikan operasi stabil jangka panjang di bawah kondisi luar ruangan umum seperti kelembapan, semprotan garam, polusi, dan beban angin. Namun, pemasangan di lokasi khusus yang mudah terbakar, meledak, mengalami korosi kimia parah, atau getaran intens harus dihindari.<\/p>\n<h2>Parameter Produk<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"72\">Nominal<\/td>\n<td colspan=\"3\" width=\"216\">Lilin baja listrik S13<\/td>\n<td colspan=\"3\" width=\"216\">Paduan amorf SH15<\/td>\n<td rowspan=\"3\" width=\"190\">Impedansi hubung singkat%<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas<\/td>\n<td>Kerugian tanpa beban<\/td>\n<td colspan=\"2\">Kerugian beban penuh W<\/td>\n<td>Kerugian tanpa beban<\/td>\n<td colspan=\"2\">Kerugian beban penuh W<\/td>\n<\/tr>\n<tr>\n<td>(kVA)<\/td>\n<td>w<\/td>\n<td>DynllYznl<\/td>\n<td>Yyno<\/td>\n<td>w<\/td>\n<td>Dynll\/Yznl<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td>80<\/td>\n<td>630<\/td>\n<td>600<\/td>\n<td>33<\/td>\n<td>630<\/td>\n<td>600<\/td>\n<td rowspan=\"12\">4<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>100<\/td>\n<td>910<\/td>\n<td>870<\/td>\n<td>43<\/td>\n<td>910<\/td>\n<td>870<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>110<\/td>\n<td>1090<\/td>\n<td>1040<\/td>\n<td>50<\/td>\n<td>1090<\/td>\n<td>1040<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>130<\/td>\n<td>1310<\/td>\n<td>1250<\/td>\n<td>60<\/td>\n<td>1310<\/td>\n<td>1250<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>150<\/td>\n<td>1580<\/td>\n<td>1500<\/td>\n<td>75<\/td>\n<td>1580<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>170<\/td>\n<td>1890<\/td>\n<td>1800<\/td>\n<td>85<\/td>\n<td>1890<\/td>\n<td>1800<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>200<\/td>\n<td>2.31<\/td>\n<td>2200<\/td>\n<td>100<\/td>\n<td>2310<\/td>\n<td>2200<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>240<\/td>\n<td>2730<\/td>\n<td>2600<\/td>\n<td>120<\/td>\n<td>2730<\/td>\n<td>2600<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>290<\/td>\n<td>3200<\/td>\n<td>3050<\/td>\n<td>140<\/td>\n<td>3200<\/td>\n<td>3050<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>340<\/td>\n<td>3830<\/td>\n<td>3650<\/td>\n<td>170<\/td>\n<td>3830<\/td>\n<td>3650<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>410<\/td>\n<td>4520<\/td>\n<td>4300<\/td>\n<td>200<\/td>\n<td>4520<\/td>\n<td>4300<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>480<\/td>\n<td>5410<\/td>\n<td>5150<\/td>\n<td>240<\/td>\n<td>5410<\/td>\n<td>5150<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>570<\/td>\n<td colspan=\"2\">6200<\/td>\n<td>320<\/td>\n<td colspan=\"2\">6200<\/td>\n<td rowspan=\"5\">4.5<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>700<\/td>\n<td colspan=\"2\">7500<\/td>\n<td>380<\/td>\n<td colspan=\"2\">7500<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>830<\/td>\n<td colspan=\"2\">10300<\/td>\n<td>450<\/td>\n<td colspan=\"2\">10300<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>970<\/td>\n<td colspan=\"2\">12000<\/td>\n<td>530<\/td>\n<td colspan=\"2\">12000<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>1170<\/td>\n<td colspan=\"2\">14500<\/td>\n<td>630<\/td>\n<td colspan=\"2\">14500<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>1360<\/td>\n<td colspan=\"2\">18300<\/td>\n<td>720<\/td>\n<td colspan=\"2\">18300<\/td>\n<td rowspan=\"2\">5<\/td>\n<\/tr>\n<tr>\n<td>2500<\/td>\n<td>1600<\/td>\n<td colspan=\"2\">21200<\/td>\n<td>865<\/td>\n<td colspan=\"2\">21200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Rincian Aplikasi<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3857\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3858\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3859\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3860\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH15-10kV-Oil-Immersed-Amorphous-Alloy-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Seri S(B)H15 adalah transformator minyak 10kV yang dilengkapi inti paduan amorf berkinerja tinggi. Dirancang untuk menggantikan transformator inti baja silikon tradisional, mereka memberikan penghematan energi yang luar biasa dan secara signifikan mengurangi pencemaran lingkungan, dengan kerugian tanpa beban sekitar 60%\u201380% lebih rendah dari model konvensional. Dengan struktur yang sepenuhnya tertutup, transformator ini sangat tahan terhadap kontaminasi atmosfer dan ideal untuk distribusi daya di jaringan perkotaan dan pedesaan, terutama di daerah dengan pasokan listrik yang tidak mencukupi, fluktuasi beban yang besar, atau kondisi pemeliharaan yang sulit.<\/p>","protected":false},"featured_media":3575,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3574","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product\/3574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/comments?post=3574"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/media\/3575"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/media?parent=3574"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_brand?post=3574"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_cat?post=3574"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/id\/wp-json\/wp\/v2\/product_tag?post=3574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}