{"id":3640,"date":"2026-11-09T09:00:32","date_gmt":"2026-11-09T01:00:32","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3640"},"modified":"2026-11-11T10:47:44","modified_gmt":"2026-11-11T02:47:44","slug":"svr-oil-immersed-line-voltage-regulator","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/fr\/product\/svr-oil-immersed-line-voltage-regulator\/","title":{"rendered":"R\u00e9gulateur de tension en ligne immerg\u00e9 \u00e0 huile SVR"},"content":{"rendered":"<h2>Pr\u00e9sentation du produit et applications<\/h2>\n<p>Le SVR est un dispositif de r\u00e9gulation de tension automatique en charge haute tension. Il est principalement install\u00e9 du c\u00f4t\u00e9 sortie d'un poste o\u00f9 le transformateur principal ne poss\u00e8de pas de capacit\u00e9 de r\u00e9gulation de tension, ainsi que dans les r\u00e9seaux de distribution avec de longues lignes de transmission. Le dispositif est particuli\u00e8rement efficace dans les r\u00e9seaux \u00e9lectriques ruraux et urbains pour stabiliser la tension et r\u00e9duire les pertes sur ligne, garantissant une tension conforme pour les utilisateurs finaux. De plus, le SVR supporte l'identification bidirectionnelle du courant, ce qui lui permet de g\u00e9rer le reflux de puissance caus\u00e9 par des sources d'\u00e9nergie distribu\u00e9e (telles que de petites centrales hydro\u00e9lectriques et stations photovolta\u00efques). Il assure des strat\u00e9gies de compensation correctes dans les r\u00e9seaux de distribution actifs modernes, en faisant un atout indispensable pour la gestion de la qualit\u00e9 de l'\u00e9lectricit\u00e9.<\/p>\n<h2>Caract\u00e9ristiques principales et conception structurelle<\/h2>\n<p>1. R\u00e9gulation automatique de la tension : Le dispositif pr\u00e9l\u00e8ve la tension de ligne en temps r\u00e9el via un contr\u00f4leur intelligent int\u00e9gr\u00e9 et commute automatiquement les positions de prise du r\u00e9gulateur de tap en charge. Il r\u00e9alise une r\u00e9gulation de tension sans intervention avec une pr\u00e9cision de r\u00e9glage de 1%, couvrant une plage de compensation allant jusqu'\u00e0 \u00b120%.<\/p>\n<p>2. Identification bidirectionnelle du courant : Il supporte le sc\u00e9nario de courant des sources d'\u00e9nergie distribu\u00e9e telles que la petite hydro\u00e9lectricit\u00e9 et l'acc\u00e8s photovolta\u00efque, et peut identifier les flux de puissance en avant et en arri\u00e8re pour assurer la mise en \u0153uvre correcte des strat\u00e9gies de r\u00e9gulation de tension.<\/p>\n<p>3. Surveillance \u00e0 distance et communication : \u00c9quip\u00e9 standard d'une interface protocole RS485\/Modbus et optionnellement d'un module GPRS\/4G, le SVR supporte la configuration \u00e0 distance des param\u00e8tres, la surveillance en temps r\u00e9el de l'\u00e9tat et le diagnostic des d\u00e9fauts. Il est enti\u00e8rement compatible avec l'acc\u00e8s \u00e0 une plateforme cloud pour la gestion des r\u00e9seaux intelligents.<\/p>\n<p>4. Protection compl\u00e8te : Le contr\u00f4leur intelligent int\u00e8gre plusieurs fonctions de protection, notamment la surtension, la sous-tension, la surintensit\u00e9 et la protection limite\/temps limite. Il verrouille automatiquement les conditions anormales pour assurer le fonctionnement s\u00e9curis\u00e9 de l'\u00e9quipement.<\/p>\n<p>5. Conception structurelle robuste : Compos\u00e9 d'un autotransformateur, d'un r\u00e9gulateur de tap triphas\u00e9 en charge et d'un contr\u00f4leur intelligent. L'autotransformateur ajuste la tension via le r\u00e9gulateur de tap, avec une plage de r\u00e9gulation de tension commune de \u00b120%. La conception immerg\u00e9e dans l'huile assure une excellente dissipation thermique et une isolation, adapt\u00e9e aux environnements ext\u00e9rieurs difficiles.<\/p>\n<h2>Param\u00e8tres du produit<\/h2>\n<table style=\"width: 60.4363%; height: 716px;\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"72\">No-load(w)<\/td>\n<td rowspan=\"2\" width=\"72\">Full load loss(W)<\/td>\n<td rowspan=\"2\" width=\"190\">No load current%<\/td>\n<td rowspan=\"2\" width=\"72\">Impendance(%)<\/td>\n<td colspan=\"3\" width=\"216\">Weight (kg)<\/td>\n<td rowspan=\"2\" width=\"72\">Size(mm) (L\u00d7W\u00d7H)<\/td>\n<td rowspan=\"2\" width=\"72\">Installation size (D\/D1)<\/td>\n<\/tr>\n<tr>\n<td>Active parts<\/td>\n<td>huile<\/td>\n<td>total<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>2500<\/td>\n<td>1<\/td>\n<td rowspan=\"11\">2<\/td>\n<td>600<\/td>\n<td>280<\/td>\n<td>1100<\/td>\n<td>1200\u00d71000\u00d71210<\/td>\n<td>550\/550<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>2800<\/td>\n<td>0.9<\/td>\n<td>670<\/td>\n<td>310<\/td>\n<td>1210<\/td>\n<td>1250\u00d71000\u00d71250<\/td>\n<td>550\/550<\/td>\n<\/tr>\n<tr>\n<td>600<\/td>\n<td>3500<\/td>\n<td>0.9<\/td>\n<td>770<\/td>\n<td>330<\/td>\n<td>1320<\/td>\n<td>1280\u00d71050\u00d71290<\/td>\n<td>550\/550<\/td>\n<\/tr>\n<tr>\n<td>700<\/td>\n<td>4000<\/td>\n<td>0.8<\/td>\n<td>880<\/td>\n<td>350<\/td>\n<td>1500<\/td>\n<td>1320\u00d71070\u00d71320<\/td>\n<td>660\/660<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>5000<\/td>\n<td>0.8<\/td>\n<td>1000<\/td>\n<td>400<\/td>\n<td>1650<\/td>\n<td>1400\u00d71100\u00d71380<\/td>\n<td>660\/660<\/td>\n<\/tr>\n<tr>\n<td>960<\/td>\n<td>6000<\/td>\n<td>0.6<\/td>\n<td>1150<\/td>\n<td>450<\/td>\n<td>1950<\/td>\n<td>1460\u00d71160\u00d71410<\/td>\n<td>660\/660<\/td>\n<\/tr>\n<tr>\n<td>1200<\/td>\n<td>7000<\/td>\n<td>0.6<\/td>\n<td>1380<\/td>\n<td>550<\/td>\n<td>2320<\/td>\n<td>1520\u00d71250\u00d71470<\/td>\n<td>660\/660<\/td>\n<\/tr>\n<tr>\n<td>1400<\/td>\n<td>10000<\/td>\n<td>0.6<\/td>\n<td>1650<\/td>\n<td>610<\/td>\n<td>2640<\/td>\n<td>1630\u00d71250\u00d71500<\/td>\n<td>820\/820<\/td>\n<\/tr>\n<tr>\n<td>1700<\/td>\n<td>12000<\/td>\n<td>0.5<\/td>\n<td>1840<\/td>\n<td>940<\/td>\n<td>3300<\/td>\n<td>1870\u00d71350\u00d71530<\/td>\n<td>820\/820<\/td>\n<\/tr>\n<tr>\n<td>1950<\/td>\n<td>4500<\/td>\n<td>0.5<\/td>\n<td>2160<\/td>\n<td>1100<\/td>\n<td>4180<\/td>\n<td>1900\u00d71450\u00d71620<\/td>\n<td>820\/820<\/td>\n<\/tr>\n<tr>\n<td>2500<\/td>\n<td>16000<\/td>\n<td>0.4<\/td>\n<td>2600<\/td>\n<td>1550<\/td>\n<td>5300<\/td>\n<td>1980\u00d71450\u00d71950<\/td>\n<td>820\/820<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>D\u00e9tails des applications<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3876\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-1-1-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3875\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-4-1-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3874\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-3-1-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3873\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-2-1-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3648\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7.webp\" alt=\"\" width=\"1200\" height=\"600\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7.webp 1200w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7-300x150.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7-1024x512.webp 1024w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7-768x384.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7-18x9.webp 18w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SVR-Oil-immersed-Line-Voltage-Regulator-7-1000x500.webp 1000w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Le SVR est un r\u00e9gulateur de tension automatique en charge, immerg\u00e9 dans l'huile, con\u00e7u sp\u00e9cifiquement pour les lignes de distribution de 6 kV, 10 kV et 35 kV. Sa fonction principale est de surveiller en temps r\u00e9el les variations de tension de ligne et d'ajuster automatiquement le rapport du transformateur pour stabiliser la tension de sortie dans une large plage de -20% \u00e0 +20%. Cela r\u00e9sout efficacement les probl\u00e8mes d'instabilit\u00e9 de tension caus\u00e9s par de longues lignes de transmission, de grandes fluctuations de charge ou l'int\u00e9gration d'\u00e9nergie distribu\u00e9e. Il est largement applicable du c\u00f4t\u00e9 sortie des postes et des r\u00e9seaux \u00e9lectriques ruraux, servant de solution technique cl\u00e9 pour am\u00e9liorer la qualit\u00e9 de l'alimentation \u00e9lectrique et r\u00e9duire les pertes sur ligne.<\/p>","protected":false},"featured_media":3641,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3640","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product\/3640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/comments?post=3640"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media\/3641"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media?parent=3640"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3640"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3640"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}