{"id":3610,"date":"2026-11-09T08:50:41","date_gmt":"2026-11-09T00:50:41","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3610"},"modified":"2026-11-11T09:19:50","modified_gmt":"2026-11-11T01:19:50","slug":"s13-10kv-and-20kv-oil-immersed-power-distribution-transformers","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/fr\/product\/s13-10kv-and-20kv-oil-immersed-power-distribution-transformers\/","title":{"rendered":"Transformateurs de distribution d'\u00e9nergie immerg\u00e9s dans l'huile S13 10kV et 20kV"},"content":{"rendered":"<h2>Pr\u00e9sentation du produit et applications<\/h2>\n<p>La s\u00e9rie S13 est compos\u00e9e de transformateurs de distribution d'\u00e9nergie enti\u00e8rement scell\u00e9s, immerg\u00e9s dans l'huile, con\u00e7us pour des syst\u00e8mes AC avec une fr\u00e9quence nominale de 50Hz et une tension de service maximale de 20kV. Ils sont principalement utilis\u00e9s comme transformateurs de distribution dans diverses entreprises industrielles, notamment dans le p\u00e9trole, la m\u00e9tallurgie, la chimie, le textile et l'industrie l\u00e9g\u00e8re, ainsi que dans des endroits avec des niveaux \u00e9lev\u00e9s de poussi\u00e8re. Les transformateurs sont con\u00e7us pour une haute efficacit\u00e9, de faibles pertes et une op\u00e9ration fiable, ce qui les rend adapt\u00e9s \u00e0 une installation en int\u00e9rieur comme en ext\u00e9rieur (l'installation en ext\u00e9rieur n\u00e9cessite d'\u00e9viter la lumi\u00e8re directe du soleil, les gaz corrosifs ou la poussi\u00e8re, tandis que l'installation en int\u00e9rieur n\u00e9cessite un espace de dissipation thermique suffisant et une distance de s\u00e9curit\u00e9).<\/p>\n<h2>Caract\u00e9ristiques principales et conception structurelle<\/h2>\n<p>1. Noyau : Le noyau est fabriqu\u00e9 en acier au silicium \u00e0 grain orient\u00e9, \u00e0 haute perm\u00e9abilit\u00e9. Il adopte une nouvelle structure avec un noyau empil\u00e9 \u00e0 joints mitr\u00e9s complets. La branche du noyau pr\u00e9sente une section circulaire \u00e0 plusieurs \u00e9tapes, et la traverse a une section \u00e9gale \u00e0 celle de la branche du noyau, assurant une haute efficacit\u00e9 magn\u00e9tique et de faibles pertes \u00e0 vide.<\/p>\n<p>2. Enroulements : Les enroulements sont con\u00e7us avec des conduits d'huile ondul\u00e9s, utilisant un processus d'impr\u00e9gnation sans vernis et fix\u00e9s avec des bandes de liaison. Tous les enroulements sont des bobines concentriques. L'enroulement haute tension est \u00e9quip\u00e9 de prises correspondant aux tensions de prise requises, qui sont connect\u00e9es au commutateur de prise. Le commutateur de prise est mont\u00e9 sur le couvercle du r\u00e9servoir, et le r\u00e9glage de la tension de prise ne peut \u00eatre effectu\u00e9 qu'apr\u00e8s coupure de courant.<\/p>\n<p>3. Dispositifs de protection de s\u00e9curit\u00e9 : Les transformateurs d'une capacit\u00e9 de 30 \u00e0 2000 kVA sont \u00e9quip\u00e9s d'une soupape de d\u00e9charge de pression. Un relais de gaz avec bornes d'alarme et de coupure peut \u00eatre install\u00e9 selon les exigences de l'utilisateur.<\/p>\n<p>4. Dispositif de mesure de la temp\u00e9rature de l'huile : Tous les transformateurs sont \u00e9quip\u00e9s d'une prise pour un thermom\u00e8tre en verre, install\u00e9 sur le dessus du r\u00e9servoir d'huile et s'\u00e9tendant dans l'huile \u00e0 une profondeur de 120\u00b110 mm. Les transformateurs d'une capacit\u00e9 de 1000 \u00e0 2000 kVA sont \u00e9quip\u00e9s d'un thermom\u00e8tre \u00e0 signal ext\u00e9rieur.<\/p>\n<p>5. R\u00e9servoir du transformateur : Le r\u00e9servoir du transformateur est construit avec des parois ondul\u00e9es, et sa surface est trait\u00e9e par une peinture en poudre pour une bonne adh\u00e9rence de la peinture. Les parois ondul\u00e9es servent \u00e0 la fois \u00e0 la dissipation de la chaleur et \u00e0 la \u201c respiration \u201d des fluctuations de volume de l'huile du transformateur caus\u00e9es par les variations de temp\u00e9rature. En cons\u00e9quence, le transformateur enti\u00e8rement scell\u00e9 \u00e9limine le besoin d'un conservateur d'huile, r\u00e9duisant la hauteur totale de l'unit\u00e9. La remplissage \u00e0 l'huile sous vide est appliqu\u00e9 lors de l'encapsulation du transformateur pour \u00e9liminer compl\u00e8tement l'humidit\u00e9 \u00e0 l'int\u00e9rieur du transformateur. L'huile du transformateur est isol\u00e9e du contact avec l'air, emp\u00eachant efficacement l'entr\u00e9e d'oxyg\u00e8ne et d'humidit\u00e9 qui d\u00e9graderait la performance de l'isolation et acc\u00e9l\u00e9rerait le vieillissement de l'huile. Par cons\u00e9quent, il n'est pas n\u00e9cessaire de r\u00e9aliser des tests r\u00e9guliers d'\u00e9chantillons d'huile.<\/p>\n<p>6. Conditions de fonctionnement : Adapt\u00e9 aux zones situ\u00e9es \u00e0 une altitude ne d\u00e9passant pas 1 000 m\u00e8tres, avec une temp\u00e9rature ambiante maximale de +40\u00b0C et une temp\u00e9rature ambiante minimale de -25\u00b0C ou -5\u00b0C. La fr\u00e9quence nominale du r\u00e9seau \u00e9lectrique connect\u00e9 est de 50Hz, et la plage de fluctuation de la tension d'alimentation ne doit pas d\u00e9passer \u00b15% de la tension nominale. Le taux de distorsion de la forme d'onde doit respecter les exigences de gestion harmonique du syst\u00e8me d'alimentation. Les transformateurs peuvent \u00eatre install\u00e9s en int\u00e9rieur ou en ext\u00e9rieur dans des endroits bien ventil\u00e9s. Pour l'installation en ext\u00e9rieur, il faut \u00e9viter la lumi\u00e8re directe du soleil, les gaz corrosifs ou l'accumulation de poussi\u00e8re ; pour l'installation en int\u00e9rieur, il faut assurer un espace de dissipation thermique suffisant et une distance de s\u00e9curit\u00e9. Le transformateur peut fonctionner en continu \u00e0 sa capacit\u00e9 nominale et poss\u00e8de une certaine capacit\u00e9 de surcharge \u00e0 court terme. En cas d'utilisation dans des environnements sp\u00e9ciaux tels que zones sujettes aux orages, humidit\u00e9 \u00e9lev\u00e9e, pollution importante, corrosion chimique ou zones sismiques, une notification pr\u00e9alable doit \u00eatre faite, et un sch\u00e9ma de protection renforc\u00e9e doit \u00eatre pr\u00e9vu.<\/p>\n<h2>Param\u00e8tres du produit<\/h2>\n<table style=\"border-collapse: collapse; width: 50.2877%; height: 604px;\" border=\"0\" width=\"648\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 54.00pt; width: 54.00pt;\" rowspan=\"4\" width=\"72\" height=\"72\">Not\u00e9<br \/>\nCapacit\u00e9<br \/>\n(kVA)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Haut<br \/>\ntension<br \/>\n(KV)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Haute tension<br \/>\nplage de prise<br \/>\n(%)<\/td>\n<td style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Basse<br \/>\ntension<br \/>\n(kV)<\/td>\n<td class=\"et2\" style=\"width: 162.00pt;\" colspan=\"3\" width=\"216\">S13-M<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">sans charge<br \/>\ncourant<br \/>\n(%)<\/td>\n<td class=\"et2\" style=\"width: 54.00pt;\" rowspan=\"4\" width=\"72\">Court-circuit<br \/>\nimp\u00e9dance%<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td class=\"et2\" colspan=\"3\">acier lamin\u00e9 \u00e9lectrique<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td rowspan=\"2\">perte \u00e0 vide kW<\/td>\n<td colspan=\"2\">perte en charge compl\u00e8te kW<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td>Dyn11\/Yzn11<\/td>\n<td>Yyno<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">30<\/td>\n<td rowspan=\"19\">63<br \/>\n10<br \/>\n10.5<\/td>\n<td rowspan=\"19\">\u00b12\u00d72,5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\" align=\"right\">0.4<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">630<\/td>\n<td align=\"right\">710<\/td>\n<td align=\"right\">1.2<\/td>\n<td rowspan=\"12\" align=\"right\">4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">50<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">910<\/td>\n<td align=\"right\">100<\/td>\n<td align=\"right\">1.04<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">63<\/td>\n<td align=\"right\">110<\/td>\n<td align=\"right\">1090<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">80<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">1310<\/td>\n<td align=\"right\">1380<\/td>\n<td align=\"right\">0.96<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">100<\/td>\n<td align=\"right\">150<\/td>\n<td align=\"right\">1580<\/td>\n<td align=\"right\">1570<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">125<\/td>\n<td align=\"right\">170<\/td>\n<td align=\"right\">1890<\/td>\n<td align=\"right\">1850<\/td>\n<td align=\"right\">0.88<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">160<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2310<\/td>\n<td align=\"right\">2130<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">200<\/td>\n<td align=\"right\">240<\/td>\n<td align=\"right\">2730<\/td>\n<td align=\"right\">2530<\/td>\n<td align=\"right\">0.8<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">250<\/td>\n<td align=\"right\">290<\/td>\n<td align=\"right\">3200<\/td>\n<td align=\"right\">2760<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">315<\/td>\n<td align=\"right\">340<\/td>\n<td align=\"right\">3830<\/td>\n<td align=\"right\">3470<\/td>\n<td align=\"right\">0.72<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">400<\/td>\n<td align=\"right\">410<\/td>\n<td align=\"right\">4520<\/td>\n<td align=\"right\">3990<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">500<\/td>\n<td align=\"right\">480<\/td>\n<td align=\"right\">5410<\/td>\n<td align=\"right\">4880<\/td>\n<td align=\"right\">0.64<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">630<\/td>\n<td align=\"right\">570<\/td>\n<td colspan=\"2\" align=\"right\">6200<\/td>\n<td align=\"right\">0.48<\/td>\n<td rowspan=\"5\" align=\"right\">4.5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">800<\/td>\n<td align=\"right\">700<\/td>\n<td colspan=\"2\" align=\"right\">7500<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1000<\/td>\n<td align=\"right\">830<\/td>\n<td colspan=\"2\" align=\"right\">10300<\/td>\n<td align=\"right\">0.48<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1250<\/td>\n<td align=\"right\">970<\/td>\n<td colspan=\"2\" align=\"right\">12000<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">1600<\/td>\n<td align=\"right\">1170<\/td>\n<td colspan=\"2\" align=\"right\">14500<\/td>\n<td align=\"right\">0.4<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2000<\/td>\n<td align=\"right\">1360<\/td>\n<td colspan=\"2\" align=\"right\">18300<\/td>\n<td align=\"right\">0.32<\/td>\n<td rowspan=\"2\" align=\"right\">5<\/td>\n<\/tr>\n<tr style=\"height: 13.50pt;\">\n<td style=\"height: 13.50pt;\" align=\"right\" height=\"18\">2500<\/td>\n<td align=\"right\">1600<\/td>\n<td colspan=\"2\" align=\"right\">21200<\/td>\n<td align=\"right\">0.32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>D\u00e9tails des applications<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3861\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-1-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3862\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-2-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3863\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-3-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3864\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/S13-10kV-and-20kV-Oil-Immersed-Power-Distribution-Transformers-4-3-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>La s\u00e9rie S13 est compos\u00e9e de transformateurs enti\u00e8rement scell\u00e9s, immerg\u00e9s dans l'huile, adapt\u00e9s aux syst\u00e8mes d'alimentation avec une fr\u00e9quence AC de 50Hz et une tension de service nominale de 20kV ou moins. Ils sont utilis\u00e9s comme transformateurs de distribution dans des entreprises telles que le p\u00e9trole, la m\u00e9tallurgie, la chimie, le textile et l'industrie l\u00e9g\u00e8re, ainsi que dans des endroits avec de grandes quantit\u00e9s de poussi\u00e8re. Les transformateurs disposent d'un noyau de haute fiabilit\u00e9 en acier au silicium \u00e0 grain orient\u00e9, d'un syst\u00e8me d'isolation avanc\u00e9 et d'un design de r\u00e9servoir d'huile enti\u00e8rement scell\u00e9, garantissant une op\u00e9ration sans maintenance et une longue dur\u00e9e de vie.<\/p>","protected":false},"featured_media":3611,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3610","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product\/3610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/comments?post=3610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media\/3611"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media?parent=3610"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3610"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3610"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}