{"id":1378,"date":"2026-06-24T15:21:23","date_gmt":"2026-06-24T07:21:23","guid":{"rendered":"https:\/\/z41763bdkq.wpdns.site\/?post_type=product&#038;p=1378"},"modified":"2026-08-01T18:06:23","modified_gmt":"2026-08-01T10:06:23","slug":"transformateur-sec-de-type-a-resine-coulee-triphase-11kv-500kva-1500kva","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/fr\/product\/11kv-500kva-1500kva-3-phase-cast-resin-dry-type-transformer\/","title":{"rendered":"Transformateur sec \u00e0 r\u00e9sine coul\u00e9e triphas\u00e9 11kv"},"content":{"rendered":"<h2>Transformateur sec \u00e0 r\u00e9sine coul\u00e9e : 500 kVA, 1000 kVA et 1500 kVA<\/h2>\n<p>Nous proposons des transformateurs secs en r\u00e9sine \u00e9poxy coul\u00e9e triphas\u00e9s de haute qualit\u00e9 11KV couvrant les capacit\u00e9s courantes de 500KVA, 1000KVA, 1500KVA, et prenons \u00e9galement en charge des sp\u00e9cifications \u00e9tendues, y compris <strong>22 kV, 2500 kVA et 5 MVA<\/strong> pour r\u00e9pondre aux diverses exigences de distribution d'\u00e9nergie. Adoptant une technologie avanc\u00e9e d'isolation solide, le transformateur abandonne tous les mat\u00e9riaux isolants et de refroidissement liquides. Ses enroulements internes sont enti\u00e8rement encapsul\u00e9s avec de la r\u00e9sine \u00e9poxy de haute puret\u00e9 par un proc\u00e9d\u00e9 de coul\u00e9e sous vide et de durcissement \u00e0 haute temp\u00e9rature, formant une structure d'isolation solide int\u00e9gr\u00e9e qui prot\u00e8ge efficacement le noyau et les bobines des interf\u00e9rences de l'environnement ext\u00e9rieur.<\/p>\n<p>L'encapsulation int\u00e9grale en r\u00e9sine \u00e9poxy conf\u00e8re au transformateur d'excellentes performances d'isolation \u00e9lectrique, ainsi qu'une forte r\u00e9sistance \u00e0 l'humidit\u00e9, \u00e0 la poussi\u00e8re, aux contaminants chimiques et aux chocs m\u00e9caniques. La conception structurelle solide et compacte \u00e9limine les dangers cach\u00e9s de fuite de liquide, de vieillissement de l'isolation et de desserrage structurel pr\u00e9sents dans les transformateurs traditionnels remplis d'huile, garantissant un fonctionnement stable et fiable \u00e0 long terme de l'\u00e9quipement.<\/p>\n<p>Comparativement aux transformateurs conventionnels remplis de liquide, notre <a href=\"https:\/\/shenhengglobal.com\/fr\/transformer\/\">transformateurs secs \u00e0 coul\u00e9e de r\u00e9sine \u00e9poxy<\/a> ont des avantages \u00e9vidents et complets. La conception structurelle optimis\u00e9e rend l'\u00e9quipement plus petit et plus l\u00e9ger, ce qui \u00e9conomise consid\u00e9rablement l'espace d'installation et r\u00e9duit les co\u00fbts de transport et d'installation. Sans liquide isolant dangereux \u00e0 l'int\u00e9rieur, le transformateur ne produit aucune pollution par fuite d'huile, respectant pleinement les normes mondiales de protection de l'environnement et d'ing\u00e9nierie verte. De plus, il pr\u00e9sente d'excellentes propri\u00e9t\u00e9s de r\u00e9sistance au feu et d'ignifugation, ce qui peut \u00e9viter efficacement les risques d'incendie et d'explosion, ce qui en fait l'\u00e9quipement \u00e9lectrique pr\u00e9f\u00e9r\u00e9 pour les sc\u00e9narios n\u00e9cessitant des exigences \u00e9lev\u00e9es en mati\u00e8re de s\u00e9curit\u00e9 incendie.<\/p>\n<p>Largement adaptable \u00e0 des sc\u00e9narios d'application diversifi\u00e9s, ce transformateur triphas\u00e9 de type sec est largement utilis\u00e9 dans la distribution d'\u00e9nergie des usines industrielles, l'alimentation \u00e9lectrique des b\u00e2timents commerciaux, l'ing\u00e9nierie des r\u00e9seaux urbains, les syst\u00e8mes d'\u00e9nergies renouvelables nouvelles, les syst\u00e8mes d'alimentation des transports et du transit ferroviaire, r\u00e9pondant ainsi aux besoins d'alimentation \u00e9lectrique de divers projets d'ing\u00e9nierie de moyenne et haute norme.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.-3-Phase-Cast-Resin-Dry-Type-Transformer.webp\" alt=\"Transformateur sec \u00e0 r\u00e9sine coul\u00e9e triphas\u00e9 11kv\" \/><\/p>\n<h2>Taille de transformateur triphas\u00e9 sec<\/h2>\n<p>A <strong>Transformateur triphas\u00e9 sec<\/strong> est g\u00e9n\u00e9ralement utilis\u00e9 pour abaisser la moyenne tension, telle que 11 kV, \u00e0 une basse tension de 400 V ou 415 V.<\/p>\n<div class=\"scroll\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Tension courante<\/th>\n<th>Utilisation typique<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>500 kVA<\/td>\n<td>11kV \/ 400V, 415V<\/td>\n<td>Petites usines, b\u00e2timents, syst\u00e8mes CVC<\/td>\n<\/tr>\n<tr>\n<td>1000 kVA<\/td>\n<td>11kV \/ 400V, 415V<\/td>\n<td>Usines moyennes, centres commerciaux, h\u00f4pitaux<\/td>\n<\/tr>\n<tr>\n<td>1500 kVA<\/td>\n<td>11kV \/ 400V, 415V<\/td>\n<td>Grandes plantes, infrastructures, centres de donn\u00e9es<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><\/h2>\n<h2>Caract\u00e9ristiques et avantages cl\u00e9s<\/h2>\n<p><strong>Haute s\u00e9curit\u00e9<\/strong><\/p>\n<p>Les transformateurs coul\u00e9s \u00e0 sec n'utilisent pas d'huile, ce qui r\u00e9duit les risques d'incendie et \u00e9vite les probl\u00e8mes de fuites d'huile.<\/p>\n<p><strong>Peu d'entretien<\/strong><\/p>\n<p>Aucun test ni remplacement d'huile n'est requis. L'entretien quotidien consiste principalement en nettoyage, inspection de ventilation et surveillance de la temp\u00e9rature.<\/p>\n<p><strong>Installation int\u00e9rieure<\/strong><\/p>\n<p>Ils conviennent aux salles \u00e9lectriques, aux sous-sols, aux b\u00e2timents commerciaux, aux h\u00f4pitaux, aux \u00e9coles et autres environnements int\u00e9rieurs.<\/p>\n<p><strong>R\u00e9sistance \u00e0 l'humidit\u00e9<\/strong><\/p>\n<p>L'isolation en r\u00e9sine \u00e9poxy aide \u00e0 prot\u00e9ger les enroulements de l'humidit\u00e9, de la poussi\u00e8re et de la corrosion.<\/p>\n<p><strong>\u00c9cologique<\/strong><\/p>\n<p>L'absence de fuite d'huile signifie un risque de pollution r\u00e9duit, ce qui les rend adapt\u00e9s aux b\u00e2timents \u00e9cologiques et aux environnements sensibles.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/1.-3-Phase-Cast-Resin-Dry-Type-Transformer.webp\" alt=\"Transformateur sec \u00e0 r\u00e9sine coul\u00e9e triphas\u00e9 11kv\" \/><\/p>\n<h2>Transformateur sec 11kV 500-1500KVA Utilisations courantes<\/h2>\n<p>Un <strong>Transformateur sec 11kV<\/strong> est couramment utilis\u00e9 pour convertir la moyenne tension de 11 kV en basse tension de 400 V ou 415 V. Les mod\u00e8les 500 kVA, 1000 kVA et 1500 kVA sont largement utilis\u00e9s dans les projets commerciaux, industriels et d'infrastructure.<\/p>\n<div class=\"scroll\">\n<table>\n<thead>\n<tr>\n<th>Capacit\u00e9<\/th>\n<th>Usages courants<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>500 kVA<\/td>\n<td>Petites usines, b\u00e2timents, \u00e9coles, syst\u00e8mes CVC<\/td>\n<\/tr>\n<tr>\n<td>1000 kVA<\/td>\n<td>Centres commerciaux, h\u00f4pitaux, ateliers, centres de donn\u00e9es<\/td>\n<\/tr>\n<tr>\n<td>1500 kVA<\/td>\n<td>Grandes plantes, a\u00e9roports, chemins de fer, sous-stations industrielles<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><\/h2>\n<h2>Comment choisir un fournisseur de transformateur triphas\u00e9 sec ?<\/h2>\n<p>Lors du choix d'un <strong>Fournisseur de transformateur sec triphas\u00e9<\/strong>, Concentrez-vous sur la qualit\u00e9 du produit, la capacit\u00e9 technique, les normes de test et le service apr\u00e8s-vente. Un fournisseur fiable doit fournir des dessins techniques clairs, la conformit\u00e9 aux normes CEI ou locales, des rapports de test de routine, des options de personnalisation et un support professionnel pour l'installation et le fonctionnement.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>Param\u00e8tre technique<\/b><\/strong><\/h2>\n<div class=\"scroll\">\n<table>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"57\">Not\u00e9<br \/>\nCapacit\u00e9<br \/>\nKVA<\/td>\n<td colspan=\"3\" width=\"205\">Voltage Combination<\/td>\n<td rowspan=\"2\" width=\"45\">Vector<br \/>\nGroup<\/td>\n<td rowspan=\"2\" width=\"57\">No-load<br \/>\nLoss(KW)<\/td>\n<td rowspan=\"2\" width=\"57\">Load<br \/>\nLoss(KW)<\/td>\n<td rowspan=\"2\" width=\"57\">No-load<br \/>\nCurrent%<\/td>\n<td rowspan=\"2\" width=\"85\">Short-circuit<br \/>\nimpedance<\/td>\n<td colspan=\"2\" width=\"91\">Weight (KG)<\/td>\n<\/tr>\n<tr>\n<td width=\"74\">Haut<br \/>\nVoltage(KA)<\/td>\n<td width=\"57\">High Voltage<br \/>\nPlage de toucher<\/td>\n<td width=\"74\">Low<br \/>\nVoltage(KA)<\/td>\n<td width=\"45\">Oil<br \/>\nWeight<\/td>\n<td width=\"45\">Gross<br \/>\nWeight<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td rowspan=\"19\" width=\"74\">6<br \/>\n6.3<br \/>\n6.6<br \/>\n10<br \/>\n10.5<br \/>\n11<\/td>\n<td rowspan=\"19\" width=\"57\">\u00b15\u00d72.5%<br \/>\n\u00b12\u00d72.5%<\/td>\n<td rowspan=\"19\">0.4<\/td>\n<td rowspan=\"19\" width=\"45\">Yyn0<br \/>\nDyn11<\/td>\n<td>0.71<\/td>\n<td>0.19<\/td>\n<td>1.6<\/td>\n<td rowspan=\"11\">4<\/td>\n<td>250<\/td>\n<td>320<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>1<\/td>\n<td>0.27<\/td>\n<td>1.4<\/td>\n<td>370<\/td>\n<td>460<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>1.38<\/td>\n<td>0.37<\/td>\n<td>1.2<\/td>\n<td>460<\/td>\n<td>550<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>1.57<\/td>\n<td>0.4<\/td>\n<td>1.1<\/td>\n<td>490<\/td>\n<td>580<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>1.85<\/td>\n<td>0.47<\/td>\n<td>1<\/td>\n<td>570<\/td>\n<td>680<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>2.13<\/td>\n<td>0.54<\/td>\n<td>1<\/td>\n<td>640<\/td>\n<td>750<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>2.52<\/td>\n<td>0.62<\/td>\n<td>0.9<\/td>\n<td>775<\/td>\n<td>890<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>2.75<\/td>\n<td>0.72<\/td>\n<td>0.8<\/td>\n<td>895<\/td>\n<td>1030<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>3.47<\/td>\n<td>0.88<\/td>\n<td>0.8<\/td>\n<td>1100<\/td>\n<td>1250<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>3.99<\/td>\n<td>0.98<\/td>\n<td>0.7<\/td>\n<td>1200<\/td>\n<td>1350<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>4.88<\/td>\n<td>1.16<\/td>\n<td>0.7<\/td>\n<td>1460<\/td>\n<td>1610<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>5.87<\/td>\n<td>1.34<\/td>\n<td>0.6<\/td>\n<td rowspan=\"8\">6<\/td>\n<td>1680<\/td>\n<td>1840<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>5.96<\/td>\n<td>1.3<\/td>\n<td>0.6<\/td>\n<td>1800<\/td>\n<td>1980<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>6.95<\/td>\n<td>1.52<\/td>\n<td>0.5<\/td>\n<td>2130<\/td>\n<td>2310<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>8.13<\/td>\n<td>1.77<\/td>\n<td>0.45<\/td>\n<td>2520<\/td>\n<td>2720<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>9.69<\/td>\n<td>2.09<\/td>\n<td>0.45<\/td>\n<td>3075<\/td>\n<td>3300<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>11.73<\/td>\n<td>2.45<\/td>\n<td>0.45<\/td>\n<td>3670<\/td>\n<td>3900<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>14.45<\/td>\n<td>3.32<\/td>\n<td>0.4<\/td>\n<td>4420<\/td>\n<td>4670<\/td>\n<\/tr>\n<tr>\n<td>2500<\/td>\n<td>17.17<\/td>\n<td>4<\/td>\n<td>0.4<\/td>\n<td>5310<\/td>\n<td>5580<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><\/h2>\n<h2><strong><b>Applicable Ambient &amp; Installation Conditions<\/b><\/strong><\/h2>\n<p>To ensure optimal operating performance and service life of the transformer, please follow the standard environmental and installation requirements below:<\/p>\n<p>\u2013 Installation Altitude: The applicable installation altitude shall not exceed 1000 meters above sea level.<\/p>\n<p>\u2013 Ambient Temperature Range: Adaptable to ambient temperatures from -30\u2103 to +40\u2103, suitable for most temperate and subtropical regional environments.<\/p>\n<p>\u2013 Installation Environment Requirements: The installation site shall be kept flat with an inclination angle less than 3 degrees. The surrounding environment must be clean and tidy, free from obvious dust, dirt, corrosive substances, flammable and explosive gases to avoid damage to the transformer insulation structure.<\/p>\n<p>\u2013 Special Customization Note: If the actual on-site operating conditions exceed the standard environmental parameters above, please contact our professional technical team in advance. We can provide targeted customized design and technical solutions to adapt to special working conditions.<\/p>\n<p>&nbsp;<\/p>\n<p><!-- shenheng-product-optimization --><\/p>\n<h3>Lecture d'ing\u00e9nierie connexe<\/h3>\n<p><a href=\"https:\/\/shenhengglobal.com\/fr\/blog\/dry-type-transformer-epc-buying-guide\/\">Guide d'achat EPC pour transformateur de type sec<\/a> \u00b7 <a href=\"https:\/\/shenhengglobal.com\/fr\/blog\/cast-resin-dry-type-transformer-maintenance-tips\/\">Cast Resin Transformer Maintenance<\/a><\/p>\n<p>Pour une revue d'ing\u00e9nierie, <a href=\"https:\/\/shenhengglobal.com\/fr\/contactez-nous\/\">contacter Shenheng Power<\/a> avec le sch\u00e9ma unifilaire approuv\u00e9, les conditions du site, les normes requises et les exigences de livraison.<\/p>","protected":false},"excerpt":{"rendered":"<p>Notre transformateur sec en r\u00e9sine coul\u00e9e triphas\u00e9 11KV est con\u00e7u avec une isolation en r\u00e9sine \u00e9poxy solide de premi\u00e8re qualit\u00e9, rempla\u00e7ant compl\u00e8tement l'isolation liquide et le milieu de refroidissement traditionnels utilis\u00e9s dans les transformateurs conventionnels. Nomm\u00e9 pour sa conception de fonctionnement enti\u00e8rement s\u00e8che et sans huile, ce transformateur s'appuie sur des mat\u00e9riaux isolants solides haute performance pour prot\u00e9ger les enroulements internes et le noyau de fer, offrant une stabilit\u00e9 d'isolation et une s\u00e9curit\u00e9 op\u00e9rationnelle exceptionnelles. Disponible en options de capacit\u00e9 de 500KVA \u00e0 1500KVA, ce transformateur sec \u00e9conome en \u00e9nergie est une solution id\u00e9ale pour une distribution d'\u00e9nergie s\u00fbre, \u00e9cologique et n\u00e9cessitant peu d'entretien pour les projets commerciaux, industriels et d'\u00e9nergies renouvelables dans le monde entier.<\/p>","protected":false},"featured_media":1409,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[72,70],"product_tag":[],"class_list":["post-1378","product","type-product","status-publish","has-post-thumbnail","product_cat-dry-type-transformer","product_cat-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product\/1378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/comments?post=1378"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media\/1409"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/media?parent=1378"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1378"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1378"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}