{"id":3634,"date":"2026-11-09T08:58:11","date_gmt":"2026-11-09T00:58:11","guid":{"rendered":"https:\/\/shenhengglobal.com\/?post_type=product&#038;p=3634"},"modified":"2026-11-11T09:48:15","modified_gmt":"2026-11-11T01:48:15","slug":"sbh25-m-10kv-three-phase-oil-immersed-amorphous-alloy-three-dimensional-wound-core-distribution-transformer","status":"publish","type":"product","link":"https:\/\/shenhengglobal.com\/de\/product\/sbh25-m-10kv-three-phase-oil-immersed-amorphous-alloy-three-dimensional-wound-core-distribution-transformer\/","title":{"rendered":"SBH25-M 10kV Dreiphasen-\u00d6l-Immersed Amorphes Legierungs-Dreidimensional gewickelter Kern-Verteilungstransformator"},"content":{"rendered":"<h2>Produkt\u00fcbersicht und Anwendungsbereiche<\/h2>\n<p>Der SBH25-M ist eine neue Generation energieeffizienter Verteiltransformatoren, die mehrere Vorteile vereinen. Sein Kern nutzt hochwertiges amorphes Legierungsmaterial und eine einzigartige dreidimensionale Wickelkerne-Struktur, was zu hervorragender magnetischer Leistung und ultra-niedrigen Leerlaufverlusten f\u00fchrt. Dies reduziert die Betriebskosten \u00fcber den gesamten Lebenszyklus erheblich und macht ihn zu einer \u00e4u\u00dferst kosteneffektiven Wahl f\u00fcr den Langzeiteinsatz. Der Transformator verf\u00fcgt \u00fcber eine vollst\u00e4ndig versiegelte Bauweise mit einem Schutzgrad von IP32 oder h\u00f6her, geeignet f\u00fcr den Au\u00dfeneinsatz an Masten und im Verteiltransformatorbereich. Die Hochspannungseite ist mit einer 10kV-Spannungsebene und einer \u201cDyn11 oder Yyn0\u201d-Vektorgruppe ausgestattet, was effektiv Harmonische unterdr\u00fcckt und die Stabilit\u00e4t der Stromqualit\u00e4t verbessert. Er wird h\u00e4ufig in Standard-Verteilungsszenarien wie der Renovierung st\u00e4dtischer und l\u00e4ndlicher Stromnetze, Photovoltaik-Netzanschluss und Gewerbegeb\u00e4uden eingesetzt.<\/p>\n<h2>Hauptmerkmale und konstruktiver Aufbau<\/h2>\n<p>1. Amorphen Legierungskern: Die Verwendung von amorpher Legierung als Kernmaterial reduziert die Leerlaufverluste drastisch (um 60%-80% im Vergleich zu herk\u00f6mmlichem Silikostahl), was zu erheblichen Energieeinsparungen und einer Reduzierung der CO2-Emissionen f\u00fchrt.<\/p>\n<p>2. Dreidimensionale Wickelkerne-Struktur (RL): Das dreidimensionale dreieckige Wickelkerndesign sorgt f\u00fcr eine gleichm\u00e4\u00dfigere magnetische Flussverteilung, niedrigere Ger\u00e4uschpegel und eine h\u00f6here Widerstandsf\u00e4higkeit gegen Kurzschlusskr\u00e4fte im Vergleich zu herk\u00f6mmlichen gestapelten Kernen.<\/p>\n<p>3. Versiegelte Bauweise (M): Der Transformator verwendet eine versiegelte Konstruktion mit einem Schutzgrad von IP32 oder h\u00f6her, was einen hervorragenden Schutz gegen raue Umweltbedingungen gew\u00e4hrleistet und den sicheren Au\u00dfeneinsatz erm\u00f6glicht.<\/p>\n<p>4. Geringe Verluste und hohe Effizienz: Der Transformator erzielt eine signifikante Reduzierung sowohl der Leerlauf- als auch der Belastungsverluste und erf\u00fcllt die Anforderungen des Energieeffizienzstandards GB 20052. Er ist in den Energieeffizienzklassen 1 und 2 (NX1 und NX2) erh\u00e4ltlich.<\/p>\n<p>5. Hohe Kurzschlussfestigkeit: Das einzigartige strukturelle Design und hochwertige Materialien gew\u00e4hrleisten eine hervorragende Kurzschlussfestigkeit, hohe Zuverl\u00e4ssigkeit und stabile Betriebsbedingungen unter verschiedenen Lasten.<\/p>\n<p>6. Breites Kapazit\u00e4tsangebot und flexible Konfiguration: Erh\u00e4ltlich in Nennleistungen von 30kVA bis 2500kVA. Hochspannungsabgriffe umfassen \u00b12\u00d72.5% und \u00b15%, mit einer Vektorgruppe von Dyn11 oder Yyn0. Die Niederspannungsseite ist 0,4kV, und die Impedanzspannung variiert je nach Kapazit\u00e4t von 4% bis 4.5% oder 5%, was Flexibilit\u00e4t f\u00fcr unterschiedliche Netzanforderungen gew\u00e4hrleistet.<\/p>\n<h2>Produktspezifikationen<\/h2>\n<table width=\"792\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"72\">Capacity<br \/>\n(kVar)<\/td>\n<td colspan=\"3\" width=\"216\">Spannungskombination und Abgriff<br \/>\nBereich(kV)<\/td>\n<td rowspan=\"2\" width=\"72\">Vektorgroup<\/td>\n<td colspan=\"2\" width=\"144\">SBH25-M<\/td>\n<td colspan=\"2\" width=\"144\">SBH21-M<\/td>\n<td rowspan=\"2\" width=\"72\">Leerlauf<br \/>\nStrom<\/td>\n<td rowspan=\"2\" width=\"72\">Impedanz<\/td>\n<\/tr>\n<tr>\n<td>Eingabe<br \/>\n(kV)<\/td>\n<td>HV-Anzapfung<br \/>\nBereich%<\/td>\n<td>Ausgang<br \/>\n(kV)<\/td>\n<td>Leerlaufverlust<\/td>\n<td>Leerlaufverlust<\/td>\n<td>Leerlauf<br \/>\nVerlust<\/td>\n<td>Leerlaufverlust<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td rowspan=\"19\">\u00a06<br \/>\n6.3<br \/>\n6.6<br \/>\n10<br \/>\n10.5<br \/>\n11<\/td>\n<td rowspan=\"19\">\u00b12\u00d72,5<br \/>\n\u00b15<\/td>\n<td rowspan=\"19\">0.4<\/td>\n<td rowspan=\"10\">Dyn11<br \/>\nYyn0<br \/>\nYzn11<\/td>\n<td>25<\/td>\n<td>510\/480<\/td>\n<td>33<\/td>\n<td>535\/510<\/td>\n<td>1.5<\/td>\n<td rowspan=\"12\">4<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>35<\/td>\n<td>735\/700<\/td>\n<td>43<\/td>\n<td>780\/745<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>40<\/td>\n<td>880\/840<\/td>\n<td>50<\/td>\n<td>930\/890<\/td>\n<td>1.1<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>50<\/td>\n<td>1060\/1010<\/td>\n<td>60<\/td>\n<td>1120\/1070<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>60<\/td>\n<td>1270\/1215<\/td>\n<td>75<\/td>\n<td>1350\/1285<\/td>\n<td>0.9<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>70<\/td>\n<td>1530\/1450<\/td>\n<td>85<\/td>\n<td>1615\/1540<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>80<\/td>\n<td>1870\/1780<\/td>\n<td>100<\/td>\n<td>1975\/1880<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>95<\/td>\n<td>2210\/2100<\/td>\n<td>120<\/td>\n<td>2330\/2225<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>110<\/td>\n<td>2590\/2470<\/td>\n<td>140<\/td>\n<td>2735\/2610<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>135<\/td>\n<td>3100\/2950<\/td>\n<td>170<\/td>\n<td>3275\/3120<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td rowspan=\"9\">Dyn11<br \/>\nYyn\u2070<\/td>\n<td>160<\/td>\n<td>3660\/3480<\/td>\n<td>200<\/td>\n<td>3865\/3675<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>190<\/td>\n<td>4380\/4170<\/td>\n<td>240<\/td>\n<td>4625\/4400<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>250<\/td>\n<td>5020<\/td>\n<td>320<\/td>\n<td>5300<\/td>\n<td>0.3<\/td>\n<td rowspan=\"5\">4.5<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>300<\/td>\n<td>6075<\/td>\n<td>380<\/td>\n<td>6415<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>360<\/td>\n<td>8340<\/td>\n<td>450<\/td>\n<td>8800<\/td>\n<td>0.3<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>425<\/td>\n<td>9720<\/td>\n<td>530<\/td>\n<td>10260<\/td>\n<td>0.2<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>500<\/td>\n<td>11745<\/td>\n<td>630<\/td>\n<td>12400<\/td>\n<td>0.2<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>550<\/td>\n<td>14000<\/td>\n<td>710<\/td>\n<td>14800<\/td>\n<td>0.2<\/td>\n<td rowspan=\"2\">5<\/td>\n<\/tr>\n<tr>\n<td>2500<\/td>\n<td>670<\/td>\n<td>15450<\/td>\n<td>860<\/td>\n<td>16300<\/td>\n<td>0.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Anwendungsdetails<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3850\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-1-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3851\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-2-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3852\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-3-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3853\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2.webp 800w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-300x300.webp 300w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-150x150.webp 150w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-768x768.webp 768w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-12x12.webp 12w, https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/11\/SBH25-M-10kV-Three-Phase-Oil-Immersed-Amorphous-Alloy-Three-Dimensional-Wound-Core-Distribution-Transformer-4-2-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Die SBH25-M-Serie ist eine Reihe von 10kV-Dreiphasen-\u00d6l-geschliffenen Verteiltransformatoren mit amorphem Legierungskern. Mit einer dreidimensional gewickelten Kernstruktur (RL) und der Verwendung von amorpher Legierung als magnetischem Material erreichen diese Transformatoren Leerlaufverluste, die etwa 60% bis 80% niedriger sind als die von herk\u00f6mmlichen Silikostahltransformatoren. Sie sind wichtige Ausr\u00fcstung f\u00fcr die energiesparende Renovierung des Stromnetzes. Die Serie entspricht den Standards GB\/T 25446 und GB 20052 und ist f\u00fcr den Au\u00dfeneinsatz an Masten oder den Einsatz im Verteiltransformatorbereich ausgelegt. Erh\u00e4ltlich in Nennleistungen von 21kVA und 25kVA, sind sie geeignet f\u00fcr eine Vielzahl von Anwendungen, einschlie\u00dflich st\u00e4dtischer und l\u00e4ndlicher Netzrenovierung, Photovoltaik-Netzanschluss und Gewerbegeb\u00e4ude.<\/p>","protected":false},"featured_media":3635,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,71,70],"product_tag":[],"class_list":["post-3634","product","type-product","status-publish","has-post-thumbnail","product_cat-products","product_cat-oil-immersed-transformer","product_cat-power-transformer","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/product\/3634","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/comments?post=3634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/media\/3635"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/media?parent=3634"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/product_brand?post=3634"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/product_cat?post=3634"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/product_tag?post=3634"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}