{"id":2007,"date":"2026-07-24T14:00:00","date_gmt":"2026-07-24T06:00:00","guid":{"rendered":"https:\/\/shenhengglobal.com\/blog\/padmount-transformer-vs-compact-substation\/"},"modified":"2026-07-24T14:00:00","modified_gmt":"2026-07-24T06:00:00","slug":"padmount-transformer-vs-compact-substation","status":"publish","type":"post","link":"https:\/\/shenhengglobal.com\/de\/blog\/padmount-transformer-vs-compact-substation\/","title":{"rendered":"When to Choose a Padmount Transformer Over a Compact Substation"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Buyers comparing a <strong>padmount transformer<\/strong> with a compact outdoor substation need a practical way to separate equipment scope, civil interface, and documentation before quotations look interchangeable.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This guide summarizes decision steps used by EPC teams and facility engineers when they decide whether a stand-alone padmount transformer is enough, or whether a factory-assembled compact substation better matches switching, LV distribution, and schedule constraints. Use it as a procurement checklist\u2014not as a substitute for project-specific engineering approval.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Project planning overview for padmount transformer selection\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/4.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Inhalt<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#Part-1.-Why-this-topic-matters-in-MV-LV-projects\">Teil 1. Warum dieses Thema bei MS-NS-Projekten wichtig ist<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-2.-Key-specification-inputs\">Teil 2. Wichtige Spezifikationseingaben<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-3.-Application-and-operating-boundaries\">Teil 3. Anwendungs- und Betriebsgrenzen<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-4.-Documentation-and-RFQ-checklist\">Teil 4. Dokumentations- und Angebotsanfrage-Checkliste<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-5.-Installation-,-testing-,-or-maintenance-notes\">Teil 5. Hinweise zu Installation, Pr\u00fcfung oder Wartung<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-6.-Product-recommendation-and-Fit-Boundary\">Teil 6. Produktempfehlung und Passform-Grenze<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#Part-7.-Common-buyer-mistakes\">Teil 7. H\u00e4ufige K\u00e4uferfehler<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-1.-Why-this-topic-matters-in-MV-LV-projects\">Teil 1. Warum dieses Thema bei MS-NS-Projekten wichtig ist<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Distribution upgrades fail quietly when procurement teams treat catalog labels as fully engineered designs. A padmount transformer and a compact substation can both serve outdoor MV-LV conversion, yet they rarely deliver the same switching scope, cable interface, or handover package.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For padmount transformer purchases, the order should reference measurable parameters\u2014voltage class, kVA, impedance, vector group, enclosure rating, and required tests\u2014rather than marketing adjectives alone. If the single-line diagram also needs MV switching and LV distribution in one outdoor bay, a compact package may reduce site assembly risk.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u00d6ffentliche Informationen abgleichen mit <a href=\"https:\/\/shenhengglobal.com\/de\/\">Shenheng Power<\/a> und best\u00e4tigen Sie die endg\u00fcltigen Grenzwerte mit Ihrem Versorgungsunternehmen oder Beratenden Ingenieur.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-2.-Key-specification-inputs\">Teil 2. Wichtige Spezifikationseingaben<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Sperren Sie diese Eingaben, bevor Sie die Gebote normalisieren:<\/p>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"Bl\u00e4tterbare Datentabelle\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Eingabe<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Warum es wichtig ist<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Typische Quelle<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bemessungsspannung und Isolationspegel<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ger\u00e4teklasse und Abstand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Einliniendiagramm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nennstrom \/ kVA<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thermische Auslegungsgrundlage<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Studie laden<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Switching and protection scope<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Padmount-only vs packaged MV\/LV bay<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Protection study<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Schaltgruppe und Anzapfungen<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Erdung und Spannungsregelung<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Versorgungsanforderungen<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Umgebung und H\u00f6he<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Derating und K\u00fchlung<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Standortdatenblatt<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil pad \/ cable basement interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Foundation and duct bank design<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Civil drawings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Technical review of padmount transformer and compact substation parameters\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/5.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fordern Sie Werkspr\u00fcfberichte und Ma\u00dfzeichnungen fr\u00fchzeitig an, damit die Teams f\u00fcr Tiefbau, Schutz und Inbetriebsetzung parallel arbeiten k\u00f6nnen.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-3.-Application-and-operating-boundaries\">Teil 3. Anwendungs- und Betriebsgrenzen<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A padmount transformer is commonly specified when the primary need is outdoor conversion on a concrete pad, with MV switching and LV boards supplied separately. It often fits residential feeders, light commercial sites, and utility laterals where the switching scheme is already defined elsewhere on the network.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A compact outdoor substation is typically preferred when the project needs a factory-integrated combination of MV switchgear, transformer, and LV distribution with a defined enclosure interface. That package can help industrial parks, renewable collection points, and schedule-driven EPC jobs that want fewer field interfaces.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Compare operating boundaries on at least four axes: switching scope, civil footprint, maintenance access, and cable entry direction. Harmonic-rich loads, corrosive atmospheres, or high altitude still require derating studies for either option.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For broader package-versus-built-on-site context, see <a href=\"https:\/\/shenhengglobal.com\/de\/blog\/power-substation-vs-prefabricated-substation-key-differences-benefits-and-applications\/\">Power Substation vs Prefabricated Substation<\/a>. For transformer-only oil-immersed selection notes, review <a href=\"https:\/\/shenhengglobal.com\/de\/blog\/how-to-choose-the-right-oil-immersed-transformer-a-buyers-guide\/\">How to Choose the Right Oil-Immersed Transformer<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-4.-Documentation-and-RFQ-checklist\">Teil 4. Dokumentations- und Angebotsanfrage-Checkliste<\/h2>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"Bl\u00e4tterbare Datentabelle\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Dokument \/ Gegenstand<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Zweck<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Wann anfordern<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Typpr\u00fcf- oder St\u00fcckpr\u00fcfbericht<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bewertungen und Verluste \u00fcberpr\u00fcfen<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vor der Bestellung<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00dcbersichtszeichnung und Fundamentlast<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tiefbau und Hebetechnik<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Entwurfsphase<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Verdrahtungs- \/ Einlinienschaltbild<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">K\u00fcndigung und Schutz<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vor dem Versand<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bedienungs- und Wartungshandbuch<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Baustellenschulung<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00dcbergabe<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ersatzteilliste<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Buchsen, Dichtungen, Sensoren<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vertragsverhandlung<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Inbetriebnahme-Checkliste<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00dcbersetzungsverh\u00e4ltnis-, Polarit\u00e4ts- und Isolationspr\u00fcfungen<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vor dem Einschalten<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Attach this table to RFQs so vendors return comparable technical packages for both padmount transformer and compact substation options.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-5.-Installation-,-testing-,-or-maintenance-notes\">Teil 5. Hinweise zu Installation, Pr\u00fcfung oder Wartung<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Installation quality often determines long-term reliability more than small differences in quoted first cost. Confirm grounding, cable bending radius, torque values, and nameplate data against the approved design for whichever package you select.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Before energization, plan ratio tests, insulation resistance checks, functional protection tests, and\u2014where applicable\u2014oil sampling or thermal monitoring baselines. Compact packages also need enclosure door interlocks and LV feeder labeling checked against the approved drawing revision.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Maintenance access should be designed into the layout: oil sampling ports for liquid-filled padmount units, and clearances for MV and LV compartments inside compact outdoor enclosures.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-6.-Product-recommendation-and-Fit-Boundary\">Teil 6. Produktempfehlung und Passform-Grenze<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">When the comparison points to a factory-assembled outdoor bay rather than a stand-alone padmount transformer, Shenheng Power publishes a relevant catalog starting point at <a href=\"https:\/\/shenhengglobal.com\/de\/product\/11kv-33kv-yb-series-compact-outdoor-electrical-substation\/\">Kompakt-Freiluft-Umspannwerk 11 kV \/ 33 kV<\/a>.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Kompakte 11-kV-\/33-kV-Freiluft-Kompaktstation zur technischen Pr\u00fcfung\" src=\"https:\/\/shenhengglobal.com\/wp-content\/uploads\/2026\/06\/6.-11KV-33KV-YB-Series-Compact-Outdoor-Electrical-Substation.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Passform-Begrenzung:<\/strong> This recommendation supports typical distribution and industrial scopes documented on the product page when MV switchgear, transformer, and LV distribution belong in one outdoor package. It is <strong>nicht<\/strong> a substitute for a stand-alone padmount transformer when the approved single-line diagram only requires conversion hardware, and it is <strong>nicht<\/strong> ein Ersatz f\u00fcr projektspezifische Studien, wenn ungew\u00f6hnliche Fehlerpegel, H\u00f6henextreme oder nationale Versorgungsregeln gelten.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Wenn Ihre Studie auf eine andere kVA-, Spannungs- oder Schaltanlagenkombination hinweist, \u00fcberpr\u00fcfen Sie den umfassenderen <a href=\"https:\/\/shenhengglobal.com\/de\/prefabricated-substation\/\">Kompakttagstation-Kategorie<\/a> und reichen Sie die Studiendaten \u00fcber <a href=\"https:\/\/shenhengglobal.com\/de\/contact-us\/\">Shenheng Power kontaktieren<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"Part-7.-Common-buyer-mistakes\">Teil 7. H\u00e4ufige K\u00e4uferfehler<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Comparing a padmount transformer quotation with a compact substation quotation without aligning switching and LV scope.<\/li>\n<li style=\"margin:0 0 8px\">Das Weglassen von H\u00f6hen-, Umgebungs- oder Geh\u00e4useanforderungen in der Anfrage (RFQ).<\/li>\n<li style=\"margin:0 0 8px\">Selecting equipment solely on first cost while ignoring civil pad, cable basement, and spare lead times.<\/li>\n<li style=\"margin:0 0 8px\">Die Inbetriebnahme vor dem Abgleich der Schutzeinstellungen und Leistungsschilddaten mit dem genehmigten Entwurf.<\/li>\n<li style=\"margin:0 0 8px\">Kopieren von allgemeinen Marketingbehauptungen in Patentanmeldungen ohne unterst\u00fctzende Zeichnungen.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"FAQ\">FAQ<\/h2>\n<h3 style=\"margin:28px 0 12px\">What is the difference between a padmount transformer and a compact substation?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A padmount transformer is typically a sealed outdoor distribution unit on a concrete pad. A compact substation usually packages MV switchgear, transformer, and LV distribution in one outdoor enclosure.<\/p>\n<h3 style=\"margin:28px 0 12px\">When should buyers choose a padmount transformer alone?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Choose a stand-alone padmount transformer when the site mainly needs MV-LV conversion and switching or LV boards are already specified as separate equipment.<\/p>\n<h3 style=\"margin:28px 0 12px\">What switching and LV functions does a compact substation typically include?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Many compact outdoor packages integrate incoming\/feeder MV switching with LV distribution around the transformer. Confirm the exact single-line diagram before comparing bids.<\/p>\n<h3 style=\"margin:28px 0 12px\">What civil and cable interfaces differ between the two packages?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Padmount units emphasize pad size, clearances, and primary\/secondary cable loops. Compact substations add enclosure footprint, basement or trench interfaces, and multi-compartment cable entry planning.<\/p>\n<h3 style=\"margin:28px 0 12px\">What documents should accompany factory shipment for either option?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fordern Sie Pr\u00fcfberichte, Aufstellungszeichnungen (GA-Zeichnungen), Schaltpl\u00e4ne, Handb\u00fccher und Ersatzteillisten an, die auf den Revisionsstand der Bestellung abgestimmt sind.<\/p>\n<h3 style=\"margin:28px 0 12px\">Wann sollten Ingenieure das Team f\u00fcr Netzanschl\u00fcsse konsultieren?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Vor dem Festlegen des Stufenschalterbereichs, des Schutzkonzepts und der Messanforderungen, die im Netzanschlussvertrag oder in der Checkliste f\u00fcr den Grid Code aufgef\u00fchrt sind.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"References\">Literaturverzeichnis<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/5998\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60076-1 Leistungstransformatoren \u2014 Teil 1: Allgemeines<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/publication\/6143\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439-1 Niederspannungs-Schaltger\u00e4tekombinationen<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE standards portal for distribution transformer requirements<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Compare padmount transformer and compact substation options by footprint, switching scope, civil interface, and RFQ inputs for utility and industrial buyers.<\/p>","protected":false},"author":1,"featured_media":1421,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2007","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/posts\/2007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/comments?post=2007"}],"version-history":[{"count":0,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/posts\/2007\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/media\/1421"}],"wp:attachment":[{"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/media?parent=2007"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/categories?post=2007"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shenhengglobal.com\/de\/wp-json\/wp\/v2\/tags?post=2007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}